文献速递主动脉疾病

AI辅助图像导航在复杂血管腔内主动脉修复中的疗效与安全性:系统综述与荟萃分析

Efficacy and safety of artificial intelligence-assisted image-guided navigation in complex endovascular aortic repair: a systematic review and meta-analysis.
PubMed 文献 · Ann Vasc Surg · 2026-10-08

该系统综述与荟萃分析比较AI辅助图像导航与常规透视在复杂血管腔内主动脉修复中的效果,纳入3项回顾性队列共332例患者。结果显示AI导航可降低辐射剂量,但透视时间、手术时间和对比剂用量无显著差异,证据仅限单一平台且为回顾性研究。

要点

  • AI辅助导航可降低复杂EVAR中的辐射剂量。
  • 透视时间、手术时间和对比剂用量未见显著改善。
  • 证据仅来自单一平台的回顾性研究,需前瞻性验证。

核心结论

  • Cydar EV辅助导航可能降低复杂血管腔内主动脉修复中的辐射剂量,但证据仅限单一平台的回顾性研究,不能确立其他AI导航系统的类效应。

研究设计与样本

  • 系统综述与荟萃分析,检索MEDLINE、Embase、Cochrane Library和Web of Science(最后检索2025年7月),纳入比较AI辅助图像导航与常规透视在复杂血管腔内主动脉修复中的研究。
  • 纳入3项回顾性队列研究,共332例患者(AI组189例,对照组143例),均评估同一款基于云的三维图像融合平台(Cydar EV)。

主要发现

  • AI辅助导航与较低的辐射剂量相关(2项研究,216例患者;MD -1435.85 mGy,95% CI -2208.84至-662.86;I2=0%)。
  • 透视时间无显著差异(MD -11.04分钟,95% CI -25.37至3.29;I2=65%)。
  • 手术时间无显著差异(MD -16.39分钟,95% CI -37.21至4.42;I2=0%)。
  • 对比剂用量无显著差异(MD -30.59 mL,95% CI -73.95至12.76;I2=94%)。
  • 死亡率和主要不良事件(单项研究)无显著差异。

临床怎么用

  • 在复杂血管腔内主动脉修复中,可考虑使用Cydar EV辅助导航以减少辐射剂量,但需认识到证据仅来自回顾性研究且限于该平台。

局限性

  • 证据仅限回顾性研究,可能存在偏倚。
  • 仅评估单一平台(Cydar EV),不能推广至其他AI导航系统。
  • 部分结局仅基于单项研究,把握度受限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Complex endovascular aortic repair exposes patients and operators to substantial radiation, contrast, and long procedures. Artificial intelligence (AI)-assisted image-guided navigation, based on cloud-based three-dimensional image fusion, has been proposed to improve intraoperative guidance, but its comparative benefit is uncertain. METHODS: We searched MEDLINE, Embase, the Cochrane Library, and Web of Science (last search July 2025) for studies comparing AI-assisted image-guided navigation with conventional fluoroscopy and digital subtraction angiography during complex endovascular aortic repair. No navigation platform was prespecified. Random-effects meta-analyses yielded mean differences (MD) with 95% confidence intervals (CI); heterogeneity was quantified with I2. Risk of bias was assessed with ROBINS-I and certainty with GRADE. RESULTS: Three retrospective cohorts (332 patients; 189 AI, 143 control), all evaluating one cloud-based platform (Cydar EV), were eligible. AI-assisted navigation was associated with a lower radiation dose (2 studies, 216 patients; MD -1435.85 mGy, 95% CI -2208.84 to -662.86; I2 = 0%). No significant differences were found in fluoroscopy time (MD -11.04 minutes, 95% CI -25.37 to 3.29; I2 = 65%), operative time (MD -16.39 minutes, 95% CI -37.21 to 4.42; I2 = 0%), or contrast volume (MD -30.59 mL, 95% CI -73.95 to 12.76; I2 = 94%). Mortality and major adverse events (single studies) did not differ significantly. CONCLUSIONS: Cydar EV-assisted navigation may reduce radiation dose during complex endovascular aortic repair, but evidence is limited to retrospective studies of a single platform and does not establish a class effect for other AI-assisted navigation systems. Prospective comparative studies across platforms are needed.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Neri Júnior JCS, Batista FC, Estevam RVA, et al. Efficacy and safety of artificial intelligence-assisted image-guided navigation in complex endovascular aortic repair: a systematic review and meta-analysis. Ann Vasc Surg. 2026. PMID: 42849568. doi:10.1016/j.avsg.2026.09.039

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。