文献速递主动脉疾病

EVAR术后动脉瘤体积测量的标准化50毫米分析模型

A Standardized 50-mm Analytical Model for Reproducible Aneurysm Volumetry after EVAR.
PubMed 文献 · Ann Vasc Surg · 2026-10-06

单中心前瞻性研究纳入98例EVAR患者,比较基于最大瘤囊扩张区固定50毫米分析段(Volmax50)与传统全长体积测量法在基线、6个月和12个月的可重复性与敏感性。Volmax50的可重复性更优,检出瘤囊增大≥5 mL的敏感性显著更高。

要点

  • Volmax50组内相关系数为0.93,高于传统方法的0.82。
  • Volmax50检出瘤囊增大≥5 mL的敏感性为92%,传统方法为68%。
  • 固定50毫米分析段可减少观察者间变异,或可辅助EVAR术后常规监测。

核心结论

  • Volmax50较传统全长体积测量法在EVAR术后腹主动脉瘤监测中提供更可重复、更敏感的体积评估。
  • 通过标准化分析区域并减少观察者相关变异,Volmax50改善了瘤囊体积变化的检出,或可作为术后常规监测的有用辅助手段。

研究设计与样本

  • 前瞻性单中心研究,纳入98例接受EVAR的患者。
  • 使用半自动分割获取瘤囊与血栓体积,并分别用传统全长体积测量法和Volmax50分析。
  • 在基线、6个月和12个月进行测量,评估一致性、观察者内与观察者间可重复性及检出瘤囊增大≥5 mL的敏感性。

主要发现

  • 基线时两种方法的瘤囊与血栓体积相当。
  • 随访中Volmax50测得瘤囊体积略大(T6:110 vs. 105 mL,P=0.041;T12:114 vs. 107 mL,P=0.019),血栓体积在T12亦略大(52 vs. 50 mL,P=0.044)。
  • Volmax50的组内相关系数为0.93(95%CI 0.90-0.96),传统方法为0.82(95%CI 0.76-0.87)。
  • Volmax50的观察者内与观察者间变异分别为2.8%和3.4%,传统方法为6.5%和7.9%。
  • Bland-Altman分析显示Volmax50偏倚更小、一致性界限更窄;检出瘤囊增大≥5 mL的敏感性为92% vs. 68%(P<0.001)。

关键数值与推荐

  • Volmax50为基于患者个体、自动识别于最大瘤囊扩张区内的固定50毫米分析段。
  • 随访时间点为基线、6个月和12个月。
  • 瘤囊增大判定阈值为≥5 mL。

临床怎么用

  • EVAR术后随访可采用Volmax50标准化50毫米分析段进行体积测量,以提高可重复性和瘤囊增大的检出敏感性。
  • 测量时应固定分析区域,减少解剖标志选择差异带来的纵向比较变异。

局限性

  • 单中心前瞻性研究,样本量为98例。
  • 随访至12个月。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Conventional volumetric assessment after endovascular aneurysm repair (EVAR) is limited by variability in anatomical landmark selection and inconsistent measurement regions, which may affect longitudinal reproducibility. This study evaluated the reproducibility and sensitivity of Volmax50, a standardized volumetric framework based on a patient-specific 50-mm analytical segment automatically identified within the region of maximal aneurysm dilatation, compared with conventional full-length volumetry. METHODS: A prospective single-center study included 98 patients undergoing EVAR. Sac and thrombus volumes were obtained using semiautomated segmentation and analyzed with 2 approaches: traditional full-length volumetry and Volmax50, which evaluates a fixed 50-mm segment centered on maximal sac dilatation. Measurements were performed at baseline, 6, and 12 months. Agreement, intraobserver and interobserver reproducibility, and sensitivity for detecting sac enlargement ≥5 mL were assessed. RESULTS: Baseline sac and thrombus volumes were comparable between methods. During follow-up, Volmax50 yielded slightly larger sac volumes (T6: 110 vs. 105 mL, P = 0.041; T12: 114 vs. 107 mL, P = 0.019) and thrombus volumes (T12: 52 vs. 50 mL, P = 0.044). Reproducibility was superior with Volmax50 (intraclass correlation coefficient [ICC] 0.93, 95% confidence interval [CI] 0.90-0.96) compared with the traditional method (ICC 0.82, 95% CI 0.76-0.87), with lower intraobserver and interobserver variability (2.8% and 3.4% vs. 6.5% and 7.9%). Bland-Altman analyses confirmed smaller bias and narrower limits of agreement. Sensitivity for detecting sac enlargement ≥5 mL was significantly higher with Volmax50 (92% vs. 68%, P < 0.001). CONCLUSION: Volmax50 provides more reproducible and sensitive volumetric assessment than conventional volumetry for abdominal aortic aneurysm surveillance after EVAR. By standardizing the analytical region and reducing observer-related variability, it improves the detection of sac volume changes and may represent a useful adjunct for routine postoperative monitoring.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Del Río-Solá ML, Roedan-Oliver J, Diez-Martínez M, et al. A Standardized 50-mm Analytical Model for Reproducible Aneurysm Volumetry after EVAR. Ann Vasc Surg. 2026. PMID: 42833581. doi:10.1016/j.avsg.2026.09.031

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。