手动与半自动AI方法评估胸主动脉瘤腔内治疗锚定区的比较

Comparing Manual and Semi-Automatic AI-Based Methods for Aortic Landing Zone Assessment for Endovascular Treatment of Thoracic Aortic Aneurysm.
PubMed 文献 · J Endovasc Ther · 2026-09-30

本研究回顾性分析35例患者,比较手动与AI辅助测量胸主动脉腔内修复(TEVAR)锚定区几何参数的一致性。结果显示多数参数ICC>0.75,一致性高,但解剖复杂区域(如0区附近)一致性降低,尤其主动脉颈锥度评估。提示AI工具可用于常规规划,但复杂解剖仍需专家复核。

要点

  • AI辅助与手动测量在多数锚定区参数上一致性高(ICC>0.75)。
  • 解剖复杂区域(0区附近)一致性降低,锥度指数ICC=0.62。
  • AI工具可减少操作者依赖和后期处理时间,但复杂病例需专家审核。

核心结论

  • AI辅助方法与手动测量在多数主动脉锚定区参数上高度一致,但解剖复杂性影响一致性,尤其近0区锥度评估。

研究设计与样本

  • 回顾性临床数据集,35例患者,采用手动和AI辅助方法评估TEVAR规划相关几何参数,使用组内相关系数(ICC)评估一致性。

主要发现

  • AI辅助与手动测量ICC值均>0.75,一致性高。
  • TRD两组无显著差异(2.2% vs 3.5%,P=.691)。
  • TRP在A组与B组间呈较高近端锥度趋势(-10.6% vs 0.8%,P=.086),B组一致性降低(ICC=0.62)。

临床怎么用

  • AI辅助基于中心线的锚定区评估可整合入常规TEVAR规划,提供与手动测量高度一致的直径、长度和锥度指数,减少操作者依赖和后期处理时间。
  • 解剖复杂弓部区域一致性降低,提示专家复核仍不可或缺。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Accurate assessment of aortic landing zones (LZs) is essential for planning thoracic endovascular aortic repair (TEVAR). Manual measurements, while the clinical standard, are time-consuming and prone to inter-operator variability. This study evaluates the reliability of an artificial intelligence (AI)-based tool for standardized LZ assessment. MATERIAL AND METHODS: A retrospective clinical data set of 35 patients was analysed using manual and an AI-assisted methods for evaluating key geometric parameters relevant to TEVAR planning: diameters at the endpoints of the proximal and distal aneurysm (P0, D0) and at the ends of the LZs (P2, D2), conicity indices (TRP, TRD), and lengths (LPLZ, LDLZ) of the proximal and distal LZs. Agreement was assessed using intraclass correlation coefficients (ICCs). The data set was stratified according to the anatomical zones of Ishimaru (Group A = 0, 1, and 2 and Group B = 3) to evaluate the influence of the anatomical location of the PLZ on the evaluation and the concordance of the method. RESULTS: Artificial intelligence-assisted and manual measurements showed strong agreement, with ICC values consistently >0.75. No significant differences were observed in TRD between groups (2.2% vs 3.5%, P = .691). However, TRP showed a trend towards higher proximal conicity in Group A vs Group B (-10.6% vs 0.8%, P = .086), with reduced agreement in Group B (ICC = 0.62). CONCLUSIONS: Artificial intelligence-assisted methods showed high concordance with manual measurements for most aortic LZ parameters. However, anatomical complexity, especially near zone 0, can affect agreement, particularly in evaluating aortic neck conicity. These findings highlight the importance of considering anatomical variability when validating AI-assisted tools for clinical planning.Clinical ImpactThis study shows that AI-assisted, centreline-based assessment of aortic landing zones can be integrated into routine TEVAR planning, providing diameters, lengths and conicity indices that agree closely with manual measurements while reducing operator dependency and post-processing time. For clinicians, this translates into faster, standardised and reproducible sizing, less variability between observers and centres, and better-supported decisions on endograft oversizing. The innovation lies in coupling deep-learning segmentation with automated detection of the maximum-area cross-section and of a fixed 25 mm sealing zone along the inner curvature. The reduced agreement observed in anatomically complex arch zones indicates where expert review remains indispensable.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Battaglia L, Spinella G, Magliocco M, et al. Comparing Manual and Semi-Automatic AI-Based Methods for Aortic Landing Zone Assessment for Endovascular Treatment of Thoracic Aortic Aneurysm. J Endovasc Ther. 2026. PMID: 42814484. doi:10.1177/15266028261479284

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。