文献速递主动脉疾病

标准肾下型EVAR术中锥形束CT联合1个月双功超声监测的单中心回顾性队列研究

Intraoperative Cone Beam CT with 1-Month Duplex Surveillance after Standard Infrarenal EVAR: A Single-Center Retrospective Cohort Study.
PubMed 文献 · Ann Vasc Surg · 2026-08-07

该单中心回顾性队列研究纳入172例标准肾下型EVAR患者,比较术中锥形束CT(CBCT)联合1个月双功超声与标准1个月CTA监测。CBCT组24个月免于检出内漏率更高(79.7% vs 63.5%,P=0.045),瘤囊增大≥5mm更少(0% vs 9.5%,P=0.0026),30天再干预无显著差异。

要点

  • CBCT联合双功超声路径与24个月免于检出内漏率更高相关。
  • CBCT组瘤囊增大≥5mm发生率为0%,CTA组为9.5%。
  • 两组30天再干预率无显著差异,术中辐射和对比剂用量无显著差异。

核心结论

  • 在单中心选定患者中,术中CBCT联合1个月双功超声可行,与标准1个月CTA监测相比30天再干预率相似,24个月估计免于检出内漏率更高。

研究设计与样本

  • 单中心回顾性队列研究,纳入2012年5月至2023年3月期间172例接受标准肾下型EVAR的患者。
  • 最终队列包括CTA监测组63例和术中CBCT联合1个月双功超声组104例。

主要发现

  • CBCT组估计24个月免于检出内漏率高于CTA组(79.7% vs 63.5%;区间log-rank χ2(1)=4.017,P=0.045)。
  • 瘤囊增大≥5mm在CTA组63例中发生6例,CBCT组103例中发生0例(9.5% vs 0.0%;Fisher精确检验P=0.0026)。
  • 30天再干预率两组无显著差异,术中辐射暴露和对比剂使用无显著差异。
  • 事后敏感性分析调整手术年份后,CBCT与24个月内任何内漏事件的关联减弱。

临床怎么用

  • 在选定标准肾下型EVAR患者中,可考虑术中CBCT联合1个月双功超声替代常规1个月CTA监测。
  • 鉴于回顾性设计及时间队列分配,常规省略1个月CTA尚需前瞻性多中心验证。

局限性

  • 回顾性设计,时间队列分配可能引入偏倚。
  • 两组监测方式不同,存在潜在检测偏倚。
  • 事后敏感性分析调整手术年份后关联减弱,需谨慎解读。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To evaluate outcomes after standard infrarenal endovascular aortic aneurysm repair (EVAR) using an institutional pathway of intraoperative cone beam computed tomography (CBCT) followed by 1-month duplex ultrasound, compared with standard 1-month computed tomography angiography (CTA) surveillance. METHODS: This was a single-center retrospective cohort study of 172 patients undergoing standard infrarenal EVAR between May 2012 and March 2023. The final cohort included 63 patients in the CTA surveillance group and 104 patients in the intraoperative CBCT plus 1-month duplex ultrasound group. The primary surveillance outcome was freedom from detected endoleak through 24 months. Secondary outcomes included sac enlargement ≥5 mm, aneurysm-related reintervention, rupture, aneurysm-related mortality, all-cause mortality, radiation and contrast exposure, and 30-day reintervention. Freedom from detected endoleak was evaluated using interval-based Kaplan-Meier analysis and compared with an interval-based log-rank test. RESULTS: Thirty-day reintervention did not differ significantly between groups. Estimated 24-month freedom from detected endoleak was higher in the cone beam CT group than in the CTA group (79.7% vs. 63.5%; interval-based log-rank χ2(1) = 4.017, P = 0.045). Sac enlargement ≥5 mm occurred in six of 63 CTA patients compared with 0 of 103 cone beam CT patients (9.5% vs. 0.0%; Fisher's exact P = 0.0026). Intraprocedural radiation exposure and contrast use were not significantly different between groups. The principal exposure difference between strategies was avoidance of routine 1-month CTA in the CBCT and duplex pathway. Post hoc sensitivity analyses adjusting for procedure year attenuated the association between CBCT and any endoleak event through 24 months, supporting cautious interpretation in the setting of temporal cohort assignment. CONCLUSION: In selected patients undergoing standard infrarenal EVAR at a single center, intraoperative CBCT followed by 1-month duplex ultrasound was feasible and was associated with similar early reintervention rates and higher estimated freedom from detected endoleak through 24 months compared with standard 1-month CTA surveillance. These findings should be interpreted cautiously given the retrospective design, temporal cohort assignment, different surveillance modalities, and potential detection bias. Prospective multicenter validation with standardized follow-up imaging is needed before routine 1-month CTA can be safely omitted.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Gara T, Sebastian A, Stone L, et al. Intraoperative Cone Beam CT with 1-Month Duplex Surveillance after Standard Infrarenal EVAR: A Single-Center Retrospective Cohort Study. Ann Vasc Surg. 2026. PMID: 42567312. doi:10.1016/j.avsg.2026.07.065

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。