文献速递主动脉疾病

非对比磁共振血管成像用于腹主动脉瘤EVAR规划:序列开发与CTA对比

Non-Contrast Magnetic Resonance Angiography for Endovascular Aneurysm Repair Planning in Abdominal Aortic Aneurysms: Acquisition Development and Comparison to Contrast-Enhanced Computed Tomography Angiography.
PubMed 文献 · J Endovasc Ther · 2026-08-21

结果显示NC-MRA观察者间变异性与CTA相当,在多数形态学测量上非劣于CTA,且在Endurant II/IIs内移植物选择上一致性良好。

要点

  • NC-MRA序列无需对比剂和电离辐射,图像质量与CTA相当。
  • NC-MRA在多数形态学测量上非劣于CTA,观察者间变异性相似。
  • 内移植物选择一致性良好,但部分观察者存在个别差异。

核心结论

  • 开发的NC-MRA序列观察者间变异性与CTA相当,在多数形态学测量上非劣于CTA。
  • 该序列易于整合入现有临床工作流程,有望用于常规临床。

研究设计与样本

  • 前瞻性纳入9例男性患者(中位年龄66[8]岁,最大AAA直径57[10] mm),行3.0 T运动分辨三维平衡稳态自由进动NC-MRA。

主要发现

  • 图像适用性评级:优秀11例(20.4%)、良好28例(51.9%)、中等15例(27.8%)。
  • 观察者间变异性均值:NC-MRA为0.74,CTA为0.73。
  • NC-MRA在所有颈部直径、一半髂动脉直径、一项长度直径和血管成角上非劣于CTA。
  • 支架选择:1名观察者两种模态完全一致,3名观察者1处差异,2名观察者1处差异。

关键数值与推荐

  • 非劣性分析采用单侧单样本t检验。
  • 观察者间一致性采用双向随机效应绝对一致性单次测量ICC。

临床怎么用

  • NC-MRA可作为无电离辐射和对比剂的EVAR规划替代方案。
  • 额外观察者培训可能进一步提升性能。

局限性

  • 样本量小(9例男性患者),需更大样本验证。
  • 部分形态学测量和支架选择仍存在观察者间差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To develop a non-contrast magnetic resonance angiography (NC-MRA) that offers an ionizing radiation and contrast agent-free alternative to computed tomography angiography (CTA) for detailed assessment of abdominal aortic aneurysms (AAAs). Secondly, the suitability of NC-MRA for endovascular aneurysm repair (EVAR) planning compared to CTA was assessed. METHODS: A motion-resolved 3-dimensional balanced steady-state free precession (bSSFP) magnetic resonance angiography (MRA) was performed at 3.0 T and optimized to achieve image quality comparable to CTA without requiring breath-holding. Nineteen morphometric measurements (diameter, length, and angle) in 9 prospectively included male patients (median age 66 [8] years; maximum AAA diameter 57 [10] mm, ClinicalTrials.gov ID: NCT05976711) were assessed by 5 observers and 3 aortic sizing specialists based on NC-MRA and standard CTA. The suitability of NC-MRA for EVAR planning was assessed through qualitative observer evaluation, interobserver agreement (2-way random-effects, absolute-agreement, single-measure intraclass correlation coefficient [ICC]), non-inferiority analysis with a 1-sided 1-sample t test, and agreement in Medtronic Endurant II/IIs endograft selection. RESULTS: The acquisition parameters of the resulting NC-MRA sequence are comparable to standard CTA. Image suitability was rated as excellent in 11 (20.4%) cases, good in 28 (51.9%) cases, and moderate in 15 (27.8%) cases. The interobserver variability for assessing morphometric parameters was comparable between NC-MRA (mean = 0.74) and CTA (mean = 0.73). The NC-MRA was non-inferior to CTA for all neck diameters, half of the iliac artery diameters, one of the length diameters, and for vessel angulation. Regarding stent selection: 1 observer showed complete agreement between modalities, 3 observers showed 1 discrepancy, and 2 observers showed 1 discrepancies. CONCLUSION: The developed NC-MRA sequence demonstrated interobserver variability comparable to CTA and was non-inferior for the majority of morphometric measurements. The sequence demonstrates potential for routine clinical use, as it is easily implementable within the current clinical workflow, with additional observer training likely to further enhance performance.Clinical ImpactThis study demonstrates a rapid, 3D non-contrast magnetic resonance angiography (NC-MRA) acquisition developed for endovascular aneurysm repair (EVAR) planning. Unlike most previously developed techniques the resulting acquisition parameters are highly comparable to computed tomography angiography (CTA), facilitating both implementation in the clinical workflow and reliable morphometric assessment. Morphometric parameters were assessed by EVAR specialists from diverse clinical backgrounds who were primarily experienced in CTA and received NC-MRA training, reflecting real-world clinical adoption. NC-MRA showed interobserver variability similar to CTA and was non-inferior for most morphometric measurements. With additional observer training, this technique may be suitable for clinical implementation.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Aalbregt E, Stehling W, Nederveen A, et al. Non-Contrast Magnetic Resonance Angiography for Endovascular Aneurysm Repair Planning in Abdominal Aortic Aneurysms: Acquisition Development and Comparison to Contrast-Enhanced Computed Tomography Angiography. J Endovasc Ther. 2026. PMID: 42629616. doi:10.1177/15266028261474370

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。