文献速递血液透析通路

单针远端回流技术实现零导管并改善功能不良动静脉瘘患者结局

Single Needle Distal Return Technique Achieves Zero Catheter and Improves Outcomes in Patients with Dysfunctional Arteriovenous Fistulas.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2026-07-04

结果显示转诊患者基线代谢更差且CVC携带率更高;

要点

  • 转诊患者基线血钾、NT-proBNP及CVC携带率显著高于中心内患者。
  • SNDR零导管方案将临时CVC使用率从24.2%降至0%。

核心结论

  • 基于SNDR的零导管策略可消除临时导管依赖、稳定代谢并改善通路结局。

研究设计与样本

  • 单中心回顾性队列研究,纳入所有因AVF功能障碍接受PTA的维持性血透患者。
  • 研究分两阶段:阶段1(2023年2月至2024年3月,常规护理)和阶段2(2024年4月至2026年2月,零导管SNDR方案)。

主要发现

  • 阶段2(n=237)较阶段1(n=215)临时CVC使用从24.2%降至0%(p<.001)。
  • PTA等待时间从4.2±2.5天缩短至1.9±1.3天(p<.001)。
  • 首次PTA后透析充分性spKt/V从1.21±0.18改善至1.48±0.15(p<.001)。

临床怎么用

  • 对功能不良AVF的PTA围术期可采用SNDR零导管策略以减少临时CVC依赖。
  • 转诊患者围术期风险更高,应优先纳入零导管管理路径。

局限性

  • 单中心回顾性设计,阶段间比较可能存在时间偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The peri-procedural window surrounding percutaneous transluminal angioplasty (PTA) for dysfunctional arteriovenous fistula (AVF) is a high risk phase often complicated by metabolic instability and temporary central venous catheter (CVC) dependence. This study characterised this window and evaluated a zero catheter multidisciplinary strategy centred on the single needle distal return (SNDR) technique. METHODS: This single centre, retrospective cohort study included all maintenance haemodialysis patients who underwent PTA for AVF dysfunction. The study had two phases: phase 1 (conventional care, February 2023 - March 2024) and phase 2 (zero catheter SNDR protocol, April 2024 - February 2026). Patients were categorised by source (in centre vs. referred). Clinical characteristics at presentation were compared between sources. Peri-procedural outcomes were compared between phases. The primary outcome was temporary CVC use. RESULTS: Four hundred and fifty-two patients (700 procedures) were included. Referred patients (n = 186) exhibited significantly worse profiles at presentation than in centre patients (n = 266): higher potassium (6.2 ± 1.9 vs. 5.1 ± 0.8 mmol/L), elevated NT-proBNP (1 850 vs. 852 pg/mL), and higher prevalence of pre-existing CVCs (31.7% vs. 0.8%, all p < .001). After SNDR protocol implementation, phase 2 (n = 237) demonstrated more dramatic improvements than phase 1 (n = 215): CVC use decreased from 24.2% to 0% (p < .001), time to PTA shortened from 4.2 ± 2.5 to 1.9 ± 1.3 days (p < .001), and first post-PTA dialysis adequacy (spKt/V) improved from 1.21 ± 0.18 to 1.48 ± 0.15 (p < .001). All 32 referred patients arriving with CVCs in phase 2 had them removed within 24 hours. Ninety day re-intervention free survival improved significantly in phase 2 (log rank p < .010). CONCLUSION: Referred patients bear a disproportionately higher burden of peri-procedural complications. Implementation of a zero catheter SNDR based strategy effectively eliminated temporary catheter dependence, stabilised metabolic profiles, and improved access outcomes, offering a reproducible framework for optimising peri-PTA care.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Wu S, Zhao D, Xu L, et al. Single Needle Distal Return Technique Achieves Zero Catheter and Improves Outcomes in Patients with Dysfunctional Arteriovenous Fistulas. Eur J Vasc Endovasc Surg. 2026. PMID: 42401280. doi:10.1016/j.ejvs.2026.06.052

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。