药物涂层球囊治疗动静脉瘘狭窄的随机试验:盲法再干预标准
OBJECTIVE: The aim of this French physician initiated, multicentre, prospective, randomised trial with blinded criteria for re-intervention was to evaluate the efficacy of paclitaxel coated balloons (DCBs) for the treatment of arteriovenous fistula stenosis.…
要点
- 改良意向治疗分析中,DCB 组 6 个月一期通畅丧失率与安慰剂组无显著差异。
- DCB 组 3 个月通畅丧失率显著低于安慰剂组,但 12 个月无差异。
- 符合方案分析中 DCB 组 6 个月通畅丧失率显著低于安慰剂组。
核心结论
- 在改良意向治疗分析中,DCB 组 6 个月一期通畅丧失率与安慰剂球囊组无显著差异。
主要发现
- 12 个月一期通畅丧失率 DCB 组 58.6% vs 安慰剂组 57.7%,p=0.57,HR=0.88(95%CI 0.57-1.35)。
临床怎么用
- 对于动静脉瘘狭窄,DCB 在 6 个月改良意向治疗分析中未显示优于安慰剂球囊,临床决策需结合符合方案分析结果综合考量。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The aim of this French physician initiated, multicentre, prospective, randomised trial with blinded criteria for re-intervention was to evaluate the efficacy of paclitaxel coated balloons (DCBs) for the treatment of arteriovenous fistula stenosis. METHODS: One hundred and fifty patients with an arteriovenous fistula stenosis were included, and 145 were randomised 1:1 in the Angioplastie au Ballon Imprégné de paclitaxel vs. angioplastie Standard pour le traitement des Sténoses sur fistule artérioveineuse trial; ClinicalTrials.gov identifier: NCT02753998 (ABISS) between a DCB (Lutonix, BD, Franklin Lakes, NJ, USA) and a placebo balloon. The main outcome was the rate of primary patency loss at 6 months. The primary analysis was performed in the modified intention to treat population. Missing outcome data were handled using a conservative imputation approach. The per-protocol analysis excluded patients who were included by mistake, not treated according to the randomisation arm, lost to follow up, or who missed a visit. RESULTS: In the modified intention to treat analysis, there was no significant difference between the groups regarding primary patency loss at 6 months (31% [22 of 70] in the DCB group vs. 42% [30 of 71] in the placebo group; p = .090; hazard ratio = 0.62 [95% confidence interval {CI} 0.36 - 1.07]). Primary patency loss was lower in the DCB than in the placebo group at 3 months (4.2% vs. 22.5%; p = .002; hazard ratio = 0.18 [95% CI 0.05 - 0.60]), but not at 12 months (58.6% vs. 57.7%; p = .57; hazard ratio = 0.88 [95% CI 0.57 - 1.35]). In the per-protocol analysis, the primary patency loss was significantly lower in the DCB group than in the placebo group (26% [16 of 61] in the DCB group vs. 50% [28 of 56] in the placebo group; p = .004). CONCLUSION: In the ABISS trial, the use of a DCB was not superior to a placebo balloon at 6 months in the modified intention to treat analysis.
引用
- Coscas R, Grimaldi L, Mercier L, et al. A Randomised Trial of Paclitaxel Coated Balloons for Arteriovenous Fistula Stenosis with Blinded Re-intervention Criteria. Eur J Vasc Endovasc Surg. 2026. PMID: 42379345. doi:10.1016/j.ejvs.2026.06.048
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。