文献速递慢性静脉疾病

大隐静脉射频消融:齐平式与传统标准消融的随机对照研究

Flush versus Standard Radiofrequency Ablation of the Great Saphenous Vein: Single-Center Experience.
PubMed 文献 · J Endovasc Ther · 2026-07-06

一项前瞻性随机对照研究比较齐平式与传统标准射频消融治疗大隐静脉功能不全,共纳入602例患者,每组301例。齐平式组术后疼痛评分显著更低(42.3±6.9 vs 48.9±8.0,P<.001),新生血管发生率更低(0.7% vs 4.0%,P=.012),复发率两组均低且无显著差异(2.0% vs 4.0%,P=.231)。

要点

  • 齐平式射频消融可显著降低术后疼痛评分。
  • 齐平式消融新生血管发生率显著低于标准消融。
  • 两组复发率低且无显著差异,血栓并发症无增加。

核心结论

  • 齐平式大隐静脉射频消融相比传统标准消融可显著改善术后疼痛并降低新生血管发生率。
  • 该队列中未观察到血栓或手术并发症增加,但需更大样本多中心研究确认。

研究设计与样本

  • 前瞻性随机对照研究,2020年1月至2024年12月单中心纳入602例接受射频消融的大隐静脉功能不全患者,齐平式组301例,标准组301例。
  • 主要终点为6个月疼痛评分(视觉模拟量表VAS)变化,次要终点包括生活质量、复发、新生血管及内皮热诱导血栓(EHIT)≥2级。

主要发现

  • 术后疼痛评分齐平式组显著低于标准组(42.3±6.9 vs 48.9±8.0,P<.001),较基线下降幅度更大(33.1% vs 22.4%)。
  • 中位随访20个月,新生血管发生率齐平式组显著更低(0.7% vs 4.0%,P=.012)。
  • 复发率两组均低且无显著差异(2.0% vs 4.0%,P=.231)。
  • 齐平式组无深静脉血栓(DVT)发生,标准组报告1例。

临床怎么用

  • 齐平式射频消融可在超声引导下于隐股交界处开始消融,无需额外设备或成本,可作为现有工作流程的实用改良。
  • 该技术可减少术后疼痛和新生血管,但疼痛绝对降幅有限,且研究对罕见不良事件把握度不足,广泛推广前需更多证据。

局限性

  • 单中心研究,对罕见不良事件把握度有限,随访时间有限,需更大规模多中心长期随访确认。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND OBJECTIVE: Radiofrequency ablation (RFA) is an established treatment for great saphenous vein (GSV) incompetence. However, neovascularization and residual reflux at the saphenofemoral junction (SFJ) remain concerning. Flush ablation, in which energy delivery is initiated directly after the SFJ, may improve outcomes. The objective was to compare clinical outcomes, pain, quality of life (QoL), and complications between flush and conventional standard RFA of the GSV. METHODS: A prospective randomized comparative study was conducted on patients undergoing endovenous RFA, using flush and conventional standard ablation between January 2020 and December 2024 at a tertiary referral center. The primary endpoint was the change in pain score (Visual Analog Scale [VAS]) at 6 months. Secondary endpoints included QoL, recurrence, neovascularization, and endovenous heat-induced thrombosis (EHIT) ≥2. RESULTS: A total of 602 consecutive patients were treated with RFA, divided into 2 equal groups: flush ablation (Group F, n = 301) and standard ablation (Group S, n = 301). Post-procedural pain scores were significantly lower in Group F compared with Group S (42.3 ± 6.9 vs 48.9 ± 8.0, P < .001), with a greater percentage reduction from baseline (33.1% vs 22.4%). In a median follow-up of 20 months, neovascularization occurred significantly less frequently in Group F (0.7% vs 4.0%, P = .012). Recurrence rates were low and comparable between groups (2.0% vs. 4.0%, P = .231). No deep vein thrombosis (DVT) occurred in Group F, while 1 case was reported in Group S. CONCLUSION: Flush RFA of the great saphenous vein was associated with significantly improved postoperative pain compared with conventional ablations. Lower rates of neovascularization were also observed. No increase in thrombotic or procedural complications was identified in this cohort. Given that this approach extends beyond current standard practice and considering the limited power for rare adverse events, these findings require confirmation in larger multicenter studies with longer follow-up before widespread adoption can be recommended.Clinical ImpactFlush radiofrequency ablation represents a simple technical modification of standard endovenous therapy for great saphenous vein incompetence. By initiating ablation at the saphenofemoral junction under ultrasound guidance, this approach minimizes the residual venous stump and is associated with lower postoperative pain scores and a reduced rate of neovascularization, without an observed increase in thrombotic or procedural risk. Importantly, the absolute reduction in pain was modest, and the study was not powered for rare adverse events. As the technique can be implemented without additional equipment or cost, it offers a practical refinement of current workflows. These findings support further evaluation of a more proximal ablation strategy in larger multicenter studies to confirm its clinical benefit and long-term durability.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Soliman M, Azhar A, Mowaphy KA, et al. Flush versus Standard Radiofrequency Ablation of the Great Saphenous Vein: Single-Center Experience. J Endovasc Ther. 2026. PMID: 42405501. doi:10.1177/15266028261463158

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。