现成多分支内移植物治疗EVAR后Ia型内漏的单中心研究
G-Branch系统采用混合构型,包含2个内分支用于腹腔干和肠系膜上动脉,2个外分支用于肾动脉。所有病例技术成功,30天内无死亡、脊髓缺血或其他主要不良事件,中位随访24个月无Ia或III型内漏,一例(14.3%)因II型内漏再干预,所有靶血管通畅无显著狭窄,动脉瘤囊无扩张。结论认为G-Branch是EVAR后Ia型内漏的有前景选择,短期至中期结果良好,需多中心大样本研究证实。
要点
- 中位随访24个月无Ia或III型内漏,靶血管均通畅。
- 仅1例(14.3%)因II型内漏需再干预,无动脉瘤囊扩张。
核心结论
- G-Branch内移植物是治疗EVAR后Ia型内漏的有前景选择,短期至中期结果良好。
研究设计与样本
- G-Branch系统为混合构型,含2个内分支(腹腔干和肠系膜上动脉)和2个外分支(肾动脉)。
- 随访计划为术后1、6、12个月及此后每年。
主要发现
- 所有病例技术成功。
- 术后30天内无死亡、脊髓缺血或其他主要不良事件。
- 中位随访24个月无Ia或III型内漏。
- 1例(14.3%)因II型内漏再干预。
- 所有靶血管通畅无显著狭窄,无动脉瘤囊扩张。
临床怎么用
- 对于EVAR后Ia型内漏,可考虑使用G-Branch现成多分支内移植物进行保留分支血管的修复。
- 术后需规律随访监测内漏、靶血管通畅性及动脉瘤囊变化。
局限性
- 单中心回顾性研究,样本量小。
- 需大规模多中心研究确认结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To investigate the clinical outcomes of use of a novel off-the-shelf multibranched endovascular stent graft in patients with type Ia endoleak after endovascular aortic repair (EVAR). METHODS: Patients who received the G-Branch endograft for type Ia endoleak after EVAR at our institution between November 2021 and July 2024 were retrospectively reviewed. The G-Branch endograft system, which has a hybrid configuration comprising 2 inner branches for the celiac axis and superior mesenteric artery and 2 outer branches for the renal arteries, was used in all cases. Follow-up assessments were scheduled at 1, 6, and 12 months after the index procedure and annually thereafter. RESULTS: Technical success was achieved in all cases. No deaths, cases of spinal cord ischemia, or other major adverse events occurred within 30 days postprocedure. No type Ia or type III endoleaks were detected during a median follow-up of 24 months. One patient (14.3%) underwent reintervention for type II endoleak. All target vessels remained patent without significant stenosis. No instances of dilatation of the aneurysm sac were observed. CONCLUSION: The G-Branch endograft represents a promising option for management of type Ia endoleak after EVAR, with favorable short-term to medium-term outcomes. A large multicenter study is warranted to confirm our findings.
引用
- Zhu Y, Zhang H, Ge Y, et al. Off-the-Shelf Multibranched Endograft for Type Ia Endoleak after Endovascular Aortic Repair: A Single-Center Study of the G-Branch Endograft. Ann Vasc Surg. 2026. PMID: 42456968. doi:10.1016/j.avsg.2026.07.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。