E-nside内嵌分支修复中自膨式与球扩式桥接支架的中期比较
基于意大利E-nside内嵌分支支架注册研究,分析2021年1月至2024年12月148例胸腹及复杂腹主动脉瘤患者的581条靶血管,比较自膨式与球扩式桥接支架。总体技术成功率99.5%,平均随访22.1个月,靶血管不稳定发生率为6.9%,自膨式组粗发生率低于球扩式组,但多变量分析后差异不显著,肾动脉靶血管与既往狭窄为独立预测因素。
要点
- E-nside内嵌分支修复总体技术成功率达99.5%,中期结果良好。
- 靶血管不稳定粗发生率自膨式3.2%低于球扩式8.3%,多变量校正后不显著。
- 肾动脉靶血管与既往靶血管狭窄是靶血管不稳定的独立预测因素。
核心结论
- E-nside内嵌分支腔内修复技术成功率高、中期结果良好,自膨式支架靶血管不稳定粗发生率较低但多变量校正后不显著。
- 肾动脉靶血管与既往靶血管狭窄是靶血管不稳定的独立预测因素。
研究设计与样本
- 回顾性注册研究,纳入意大利E-nside内嵌分支支架注册研究2021年1月至2024年12月的148例患者。
- 共分析581条靶血管,其中423条(72.8%)使用球扩式桥接支架,158条(27.2%)使用自膨式桥接支架。
- 主要终点为靶血管不稳定复合终点,次要终点包括技术成功率和再干预率。
主要发现
- 总体技术成功率为99.5%。
- 平均随访22.1±12.3个月,40/581条靶血管(6.9%)发生靶血管不稳定。
- 自膨式组靶血管不稳定发生率为3.2%,球扩式组为8.3%(P = .03)。
- 多变量分析显示该差异不显著,仅肾动脉靶血管(OR 1.87,95%CI 1.05-3.82,P = .045)和既往靶血管狭窄(OR 1.93,95%CI 1.13-4.11,P = .047)为独立预测因素。
关键数值与推荐
- 靶血管不稳定定义为闭塞、显著狭窄、IC/IIIB/IIIC型内漏、扭结、脱接、破裂或靶血管相关死亡的复合终点。
- 技术成功率为99.5%,靶血管不稳定总体发生率为6.9%。
- 自膨式与球扩式靶血管不稳定发生率分别为3.2%与8.3%(P = .03)。
- 肾动脉靶血管OR 1.87(95%CI 1.05-3.82,P = .045),既往狭窄OR 1.93(95%CI 1.13-4.11,P = .047)。
临床怎么用
- E-nside内嵌分支修复可用于胸腹及复杂腹主动脉瘤,技术成功率高。
- 选择桥接支架时不宜仅凭粗发生率偏好自膨式支架,需结合多变量因素评估。
- 对肾动脉靶血管及存在既往狭窄的靶血管应加强随访监测。
局限性
- 为注册研究分析,原文摘要未报告研究设计类型细节与混杂控制方式。
- 自膨式与球扩式支架的选择可能存在适应证偏倚,多变量校正后差异不显著。
- 平均随访22.1个月,中期结果尚不足以评价远期耐久性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To compare the outcomes of self-expandable (S-EXP) and balloon-expandable (B-EXP) bridging stents used with the E-nside off-the-shelf inner-branch endograft for thoracoabdominal and complex abdominal aortic aneurysm repair within the ItaliaN Branched Registry of E-nside EnDograft registry. METHODS: All patients enrolled in the ItaliaN Branched Registry of E-nside EnDograft registry between January 2021 and December 2024 were analyzed. Clinical, anatomical, and procedural data were collected for all target vessels (TVs). The most frequently used S-EXP and B-EXP bridging stents were identified and compared. The primary endpoint was target-vessel instability (TVI), defined as a composite of occlusion, significant stenosis, type IC/IIIB/IIIC endoleak, kinking, disconnection, rupture, or TV-related mortality. Secondary endpoints included technical success and reintervention rates. RESULTS: A total of 581 TVs from 148 patients were analyzed: 423 (72.8%) were bridged with B-EXP and 158 (27.2%) with S-EXP stents. Overall technical success was 99.5%. During a mean follow-up of 22.1 ± 12.3 months, TVI occurred in 40/581 vessels (6.9%), with a lower incidence in the S-EXP group (3.2%) compared with the B-EXP group (8.3%; P = .03). However, this association did not remain statistically significant at multivariable analysis, which identified only renal TVs (odds ratio, 1.87; 95% confidence interval, 1.05-3.82; P = .045) and pre-existing TV stenosis (odds ratio, 1.93; 95% confidence interval, 1.13-4.11; P = .047) as independent predictors of TVI. CONCLUSIONS: Inner-branch endovascular repair with the E-nside endograft achieved high technical success and favorable midterm outcomes. A lower crude rate of TVI was observed with S-EXP stents; however, this association did not remain significant after multivariable adjustment. Renal TVs and pre-existing stenosis were identified as the main predictors of instability.
引用
- Mezzetto L, Squizzato F, Simonte G, et al. Self-expandable versus balloon-expandable bridging stents in off-the-shelf inner branch repair: Midterm results from the ItaliaN Branched Registry of E-nside EnDograft Registry. J Vasc Surg. 2026. PMID: 42392549. doi:10.1016/j.jvs.2026.06.152
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。