血管内超声引导减少肾下腹主动脉瘤腔内修复术对血管造影的依赖:系统综述与Meta分析
该系统综述与Meta分析纳入6项队列研究共577例肾下腹主动脉瘤患者,比较血管内超声(IVUS)引导与常规血管造影辅助EVAR。IVUS组技术成功率达99.8%,显著减少碘对比剂用量、透视时间和辐射剂量,不增加早期内漏风险,但手术时间无差异。
要点
- IVUS引导EVAR可显著减少碘对比剂用量(MD -53.57 mL)。
- IVUS引导EVAR缩短透视时间并降低辐射剂量,不增加早期内漏。
- 两组手术时间无显著差异,IVUS组技术成功率达99.8%。
核心结论
- IVUS引导肾下腹主动脉瘤EVAR与减少碘对比剂用量、缩短透视时间和降低辐射暴露相关。
研究设计与样本
- 系统检索MEDLINE、Embase和Cochrane数据库至2026年2月,纳入比较IVUS引导与血管造影辅助EVAR的原始研究。
- 共纳入6项队列研究、577例患者,其中248例(43%)接受IVUS引导修复。
- 采用随机效应Meta分析,二分类变量计算 pooled OR 及95%CI,连续变量计算MD及95%CI。
主要发现
- IVUS辅助EVAR的主要技术成功率为99.8%。
- IVUS组碘对比剂用量显著少于血管造影组(MD -53.57 mL;95%CI -61.39至-45.75;P<0.00001)。
- IVUS组透视时间显著短于血管造影组(MD -10.89 min;95%CI -15.20至-6.58;P<0.00001)。
- IVUS组患者辐射剂量显著低于血管造影组(MD -418.58 mGy;95%CI -609.53至-227.62;P<0.0001)。
- 两组手术时间无显著差异(MD 4.13 min;95%CI -17.65至25.92;P=0.71),早期内漏发生率相似(IVUS组5.9% vs 血管造影组5.6%;OR 1.02;95%CI 0.46至2.26;P=0.95)。
临床怎么用
- 对于肾下腹主动脉瘤EVAR,可考虑使用IVUS引导以减少碘对比剂用量和辐射暴露。
- IVUS引导不增加早期内漏风险,但需注意手术时间可能无明显缩短。
局限性
- 纳入研究均为队列研究,可能存在选择偏倚和混杂因素。
- 样本量有限(577例),需更大队列或随机对照研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Intravascular ultrasound (IVUS) guidance during endovascular aortic aneurysm repair (EVAR) offers potential advantages in improving technical outcomes. This study aimed to perform a meta-analysis comparing IVUS-guided to conventional angiography-assisted EVAR for infrarenal abdominal aortic aneurysms (AAAs). METHODS: A systematic search of MEDLINE, Embase, and Cochrane databases was conducted from inception through February 2026. Eligible studies included original research comparing IVUS-guided with angiography-assisted EVAR for AAAs. A random-effects meta-analysis was performed in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Pooled odds ratios (ORs) with 95% confidence intervals (CIs) were calculated for dichotomous outcomes, while continuous variables were analyzed using mean differences (MDs) with 95% CI. RESULTS: Six cohort studies involving 577 patients were included, with 248 patients (43%) undergoing IVUS-guided repair. Baseline characteristics were comparable across studies. Primary technical success was achieved in 99.8% of IVUS-assisted EVAR procedures. IVUS-guided procedures required significantly less iodine contrast (MD: -53.57 mL; 95% CI: -61.39 to -45.75; P < 0.00001), had shorter fluoroscopy times (MD: -10.89 min; 95% CI: -15.20 to -6.58; P < 0.00001), had similar operative times (MD: 4.13 min; 95% CI: -17.65 to 25.92; P = 0.71), and demonstrated inferior patient radiation (radiation dose in milligray) exposure (MD: -418.58 milligray (mGy); 95% CI: -609.53 to -227.62; P < 0.0001). The rate of early endoleaks was similar between IVUS-guided (5.9%) and angiography-assisted (5.6%) EVAR (OR: 1.02; 95% CI: 0.46 to 2.26; P = 0.95). CONCLUSION: IVUS-guided EVAR for AAAs is associated with reduced iodine contrast use, decreased fluoroscopy time, and reduced patient radiation exposure.
引用
- Fernandez MG, Pimentel-Junior D, Baumgardt Barbosa Lima G, et al. Reducing Angiographic Dependence in Endovascular Repair of Infrarenal Abdominal Aortic Aneurysms Through Intravascular Ultrasound Guidance: A Systematic Review and Meta-Analysis. Ann Vasc Surg. 2026. PMID: 42442530. doi:10.1016/j.avsg.2026.06.052