本研究利用患者个体化计算流体力学分析3例接受WeFlow-JAAA内分支支架治疗的近肾腹主动脉瘤术后病例,模拟双侧肾动脉开口从近端至原解剖位置的渐进性远端迁移。结果发现远端开口位置肾灌注率更高,但伴随肾周主动脉壁不良血流动力学(低TAWSS、高OSI/RRT);近端位置虽减轻不良WSS模式,却损害肾灌注并在内分支平行段终止处远端腹主动脉产生明显血流紊乱。

要点

  • 远端肾动脉开口位置可提高肾灌注率,但肾周主动脉壁出现低TAWSS和高OSI/RRT的不良血流动力学。
  • 近端开口位置虽改善肾周WSS模式,却降低肾灌注并导致内分支平行段远端腹主动脉明显血流紊乱。
  • WeFlow-JAAA术后肾动脉开口位置可能显著影响术后血流动力学,需个体化权衡灌注与主动脉壁重塑风险。

核心结论

  • WeFlow-JAAA植入后肾动脉开口位置可能关键性影响术后血流动力学。
  • 远端放置最大化肾灌注可能使肾周主动脉壁暴露于较不利的长期WSS条件。
  • 近端放置虽减轻不良肾周WSS模式,但损害肾灌注并产生远端腹主动脉明显血流紊乱。

研究设计与样本

  • 对3例接受WeFlow-JAAA内分支支架治疗的近肾腹主动脉瘤术后病例进行患者个体化计算流体力学分析。
  • 每例系统模拟双侧肾动脉开口从近端(近腹腔动脉)至原解剖位置的渐进性远端迁移,共4个模型。

主要发现

  • 远端肾动脉开口位置较近端位置 consistently 产生更高的肾灌注率。
  • 远端位置伴随肾动脉开口邻近肾周主动脉壁出现低TAWSS和高OSI/RRT的不良血流动力学条件。
  • 近端位置减轻不良肾周WSS模式,但损害肾灌注并在内分支平行段终止处远端腹主动脉产生明显血流紊乱。

临床怎么用

  • WeFlow-JAAA术后应审慎并可能个体化考虑器械放置位置,以平衡肾灌注与主动脉壁重塑风险。
  • 肾动脉开口位置选择需同时评估肾灌注收益与肾周主动脉壁长期WSS不良风险。

局限性

  • 初步发现基于3例术后病例的计算流体力学模拟,样本量小。
  • 结果为模拟研究,需进一步临床验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To investigate the hemodynamic consequences of renal artery ostium positioning following endovascular repair of juxtarenal abdominal aortic aneurysms (JAAAs) using the novel WeFlow-JAAA inner-branch system. METHODS: Patient-specific computational fluid dynamics analysis was performed on 3 postoperative JAAA cases treated with the WeFlow-JAAA endograft. For each case, 4 models systematically simulated progressive distal migration of the bilateral renal ostia, ranging from a proximal position near the celiac artery to their native anatomical locations. Renal perfusion rates, aortic flow patterns, and established wall shear stress (WSS)-derived metrics (time-averaged wall shear stress [TAWSS], oscillatory shear index [OSI], relative residence time [RRT]) were quantitatively evaluated. RESULTS: Distal renal ostium positioning consistently yielded higher renal perfusion rates compared to proximal placements. However, this improved perfusion was associated with the development of potentially adverse hemodynamic conditions (characterized by low TAWSS and high OSI/RRT) on the perirenal aortic wall adjacent to the ostia. Conversely, proximal placements, while mitigating these adverse perirenal WSS patterns, compromised renal perfusion and generated pronounced flow disturbances in the infrarenal aorta distal to the termination of the inner-branch parallel segments. CONCLUSION: The preliminary findings suggest that renal ostium positioning after WeFlow-JAAA implantation may critically influence postoperative hemodynamics. The simulations indicate maximizing renal perfusion via distal placement may potentially expose the perirenal aortic wall to less favorable long-term WSS conditions. These results underscore the need for careful and potentially patient-specific consideration of device placement to appropriately balance perfusion and aortic wall remodeling risks in juxtarenal endovascular repair.