改良Snare-Ride技术在FB-EVAR靶血管支架置入中的应用
本文介绍一种用于开窗/分支腔内修复(FEVAR/BEVAR)中靶血管插管的改良Snare-Ride补救技术。该技术通过建立贯通导丝通路,将鞘管推进至靶血管开口处固定导丝,避免将整个圈套系统送入血管,以减少血管壁机械损伤。适用于复杂解剖或传统技术失败时,但需注意器械与鞘管尺寸兼容性。
要点
- 改良Snare-Ride技术避免将圈套系统送入靶血管,降低内皮损伤风险。
- 通过贯通导丝和可调弯鞘增强支撑与控制,便于靶血管插管和桥接支架输送。
- 适用于复杂解剖或传统插管技术失败时的补救,需注意器械尺寸兼容性。
核心结论
- 改良Snare-Ride技术是一种可重复的补救策略,可在复杂解剖中稳定鞘管位置并可能减少内脏动脉损伤风险。
研究设计与样本
- 本文为技术描述性文章,介绍改良Snare-Ride技术的操作步骤和临床应用考量,未报告样本量或研究设计细节。
主要发现
- 该技术通过建立从门脉到对侧硬鞘的贯通通路,将下位硬鞘推进至靶血管开口固定导丝,再沿导丝推进鞘管完成插管。
- 改良点在于避免将整个圈套系统送入血管,利用贯通通路提高推送性、控制和输送性,减少血管壁机械损伤。
临床怎么用
- 在FB-EVAR中靶血管插管困难或传统技术失败时,可选择性采用改良Snare-Ride技术作为补救方案。
- 操作需确保器械与鞘管尺寸兼容,并利用可调弯鞘增强导丝支撑和控制。
局限性
- 技术可行性依赖于器械和鞘管尺寸的兼容性。
- 本文未报告临床结局数据,安全性和有效性需进一步研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The field of endovascular surgery continues to evolve rapidly with the introduction of novel techniques and devices. Among the most significant advances in recent decades is the development of branched and fenestrated endografts, which have become the cornerstone of treatment for complex aortic pathologies, including thoracoabdominal aortic aneurysms. These devices enable the preservation of visceral vessel perfusion while allowing for effective aneurysm exclusion. However, their use introduces technical challenges that demand a high level of expertise, particularly during the catheterization of target vessels. Target vessel cannulation is widely recognized as one of the most technically demanding and time-consuming steps in fenestrated and branched endovascular aneurysm repair (FEVAR and BEVAR, respectively). This difficulty is often exacerbated in patients with hostile anatomy - such as extreme aortic angulation, severe vessel tortuosity, small-caliber, or heavily calcified arteries. In such settings, prolonged attempts at vessel catheterization may increase the risk of complications, including ischemic injury to abdominal organs, dissection, perforation, or embolization due to plaque disruption. To address these procedural challenges, several bailout strategies have been introduced. These techniques are generally reserved for non-standard cases and are not employed in routine or straightforward anatomies. One such strategy is the snare-ride technique, which has gained recognition as a practical and reproducible approach using widely available endovascular tools. It involves the snaring of a guidewire from the aortic component and advancing the wire and the snare assembly into the target vessel, using femoral access. While effective, this technique has raised concerns about its potential to cause endothelial trauma, particularly when the snare is advanced into a diseased vessel. To mitigate these risks, we propose modifying the traditional snare-ride technique. In this article, we introduce the Modified Snare-Ride Technique, a bailout approach designed to enhance the safety and effectiveness of target vessel cannulation in anatomically complex settings. After obtaining access to the intended target vessel with a stiff supporting wire, large sheath, and a deflecting sheath for control, through-and-through access is obtained from the portal to the contralateral stiff sheath. Once established, the lower stiff sheath is advanced to the origin of the target vessel, thereby pinning the through-and-through wire in position near the target vessel orifice. In doing so, the portal sheath can then be advanced along the through-and-through wire to the vessel origin for easy cannulation and delivery of the bridging stent. The modification avoids advancing the entire snare system into the vessel and instead uses a through-and-through access to improve pushability, control, and deliverability. This adjustment minimizes mechanical damage to the vessel wall and reduces the risk of vascular injury. However, its usability is dependent upon device and sheath size compatibility. By enhancing wire support and control with deflectable sheaths, this modified strategy provides an alternative that can be selectively employed when traditional techniques fail or are unsafe.Clinical ImpactTarget vessel catheterization remains one of the most challenging steps in fenestrated and branched endovascular aneurysm repair, particularly in patients with complex anatomy and unfavorable branch orientation. The modified Snare-Ride technique provides a reproducible bailout strategy that stabilizes sheath positioning at the target vessel origin while potentially reducing the risk of visceral artery injury associated with the original technique. By facilitating target vessel incorporation in difficult anatomical scenarios, this approach may expand endovascular treatment options, improve technical success rates, and reduce the need for more invasive alternative catheterization strategies.
引用
- Nunes VA, Gomes VC, Wood JC, et al. Modified Snare-Ride Technique for Target Vessel Stenting in FB-EVAR. J Endovasc Ther. 2026. PMID: 42366793. doi:10.1177/15266028261457367
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。