文献速递慢性静脉疾病

IVENUS人工智能模型:基于下肢照片自动进行CEAP分类

Development and validation of the IVENUS artificial intelligence model for automated CEAP classification of early-stage chronic venous disease using lower limb photographs.
PubMed 文献 · J Vasc Surg Venous Lymphat Disord · 2026-04-21

本研究开发并验证了IVENUS人工智能模型,用于基于下肢照片自动分类早期慢性静脉疾病(C0-C2 CEAP临床分级)。多中心横断面研究纳入10745张下肢照片,外部验证子集1622张照片的总体诊断准确率为84.8%,精确率84.3%,敏感度84.3%,特异度92.3%。该模型对早期CVD具有较高诊断价值,可作为临床决策支持系统。

要点

  • IVENUS模型基于下肢照片自动分类C0-C2期慢性静脉疾病。
  • 外部验证准确率84.8%,敏感度84.3%,特异度92.3%。
  • 模型可用于患者自筛、远程医疗分诊及专科随访。

核心结论

  • IVENUS人工智能模型对早期慢性静脉疾病(C0-C2期)具有高诊断价值,足以作为临床决策支持系统应用。

研究设计与样本

  • 多中心横断面研究(NCT17122021),于2020年5月至2024年1月在俄罗斯多家诊所收集10745张下肢照片,使用智能手机和专业相机拍摄,经标准化和匿名化后用于模型训练。
  • CEAP临床分级由三位有静脉病学经验的外科医生共识确定。
  • AI模型IVENUS基于Swin Transformer V2架构的深度学习方法开发,训练时采用高斯模糊和颜色抖动作为数据增强方法。

主要发现

  • 数据集包含C0期673条下肢、C1期4445条下肢、C2期5627条下肢。
  • 在1622张照片的外部验证子集中,总体诊断准确率为84.8%,精确率为84.3%,敏感度为84.3%,特异度为92.3%。

临床怎么用

  • 该模型可支持患者自我筛查和远程医疗分诊,也可供专科医生用于自动患者分流和治疗进展追踪。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Chronic venous disease (CVD) is one of the most common vascular disorders, affecting millions of people worldwide. Owing to the variability of clinical symptoms and the subjective nature of their interpretation, diagnosing CVD at an early stage is complicated, making it crucial for patients to consult a specialist. It was hypothesized that an artificial intelligence (AI) model could accurately classify CVD (C0-C2 Clinical, Etiology, Anatomy, and Pathophysiology (CEAP) clinical class) from lower limb photographs. Therefore, this study aimed to develop and validate such a model. METHODS: A multicenter cross-sectional study (NCT17122021) was conducted from May 2020 to January 2024 in accordance with the Declaration of Helsinki. A dataset of 10,745 lower limb photographs was collected using smartphones and professional cameras across several Russian clinics, then standardized and anonymized before model training. CEAP clinical class was determined by consensus among three surgeons experienced in phlebology. The AI model IVENUS was developed to automatically assess lower limb photographs and classify early-stage CVD according to the CEAP clinical classification (C0-C2). The model was trained using a deep learning approach based on the Swin Transformer V2 architecture. To improve model robustness and reduce overfitting, Gaussian blurring and color jitter were applied as data augmentation methods during training. The standard performance metrics (sensitivity, recall, specificity, accuracy, and precision) were calculated. RESULTS: The dataset consisted of 673 lower limbs of stage C0, 4445 lower limbs of stage C1, and 5627 lower limbs of stage C2. The overall diagnostic accuracy in the external validation subset of 1622 photographs was 84.8%, with a precision of 84.3%, sensitivity of 84.3%, and specificity of 92.3%. CONCLUSIONS: The AI model IVENUS demonstrated high diagnostic value for early-stage CVD, sufficient for its application as a clinical decision support system. Therefore, this model may support patient self-screening and telemedicine triage and may be used by specialists for automated patient routing and tracking of treatment progress.

来源:J Vasc Surg Venous Lymphat Disord,查看原文。版权归原作者所有。

引用

  1. Denisov V, Chistogov M, Averin D, et al. Development and validation of the IVENUS artificial intelligence model for automated CEAP classification of early-stage chronic venous disease using lower limb photographs. J Vasc Surg Venous Lymphat Disord. 2026. PMID: 42025953. doi:10.1016/j.jvsv.2026.102503

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。