基于解剖分型的单侧髂股静脉慢性闭塞再通中的辐射暴露
本研究为单中心回顾性队列,纳入133例成功行腔内再通支架置入的单侧髂股慢性静脉闭塞患者,采用Jalaie CVO分型评估辐射暴露差异。结果显示辐射暴露随CVO分型升高而增加,IV型病变、BMI、总支架长度和手术时间与辐射剂量独立相关。
要点
- CVO分型越高,辐射暴露越大,III/IV型较I型透视时间和剂量面积乘积更高。
- 置入2或3枚支架较单枚支架与更高的累积空气比释动能和剂量面积乘积相关。
- 手术时间、BMI、总支架长度和IV型闭塞是辐射剂量的独立预测因素。
核心结论
- 单侧髂股CVO腔内再通中辐射暴露随病变严重程度增加。
- CVO IV型、BMI、总支架长度和手术时间是辐射剂量的独立相关因素。
研究设计与样本
- 回顾性单中心队列研究,纳入133例单侧髂股CVO成功行腔内再通支架置入的患者,使用移动C臂透视,时间为2017年2月至2023年1月。
- 病变采用Jalaie CVO分型系统分类,系统记录辐射参数和手术数据。
主要发现
- III型和IV型病变较I型病变透视时间更长,累积空气比释动能和剂量面积乘积更高(p < .001)。
- 与单枚支架置入相比,使用2枚或3枚支架与更高的累积空气比释动能(p < .001和p = .006)和剂量面积乘积(p < .001和p = .008)相关。
- 多变量分析中,透视时间由总手术时间(p < .001)和BMI(p = .024)独立预测。
- 累积空气比释动能和剂量面积乘积由总手术时间(p < .001)、BMI(p < .001)、总支架长度(p = .035和p = .015)和IV型闭塞(p = .020和p = .034)独立预测。
临床怎么用
- 对于CVO分型较高、BMI较高、预计需要长支架或手术时间较长的患者,应关注辐射防护优化。
- 术中可参考分型、支架长度和手术时间等因素预估辐射剂量并采取相应措施。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The aim of this study was to evaluate differences in radiation exposure across chronic venous obstruction (CVO) classification groups during endovascular recanalisation and stenting of unilateral iliofemoral lesions and to identify clinical and procedural factors influencing radiation dose. METHODS: This was a retrospective, single centre cohort study of 133 patients with unilateral iliofemoral CVO who underwent successful endovascular recanalisation and stenting with mobile C arm fluoroscopy between February 2017 and January 2023. Lesions were classified using the Jalaie CVO classification system. Radiation parameters included fluoroscopy time (FT), cumulative air kerma (CAK), kerma area product (KAP), entrance skin dose, and effective dose. Procedure data included total stent length and procedure time. Radiation and procedure parameters were recorded systematically in the institutional database and subsequently analysed across classification groups. Statistical analyses involved Mann-Whitney U test, Pearson and Spearman correlation analyses, and multivariable linear regression. RESULTS: Radiation exposure increased with higher CVO classification. Type III and IV lesions were associated with longer FT and higher CAK and KAP than type I lesions (p < .001). Compared with single stent implantation, use of two or three stents was associated with higher CAK (p < .001 and p = .006, respectively) and KAP (p < .001 and p = .008, respectively). In multivariable analysis, FT was independently predicted by total procedure time (p < .001) and body mass index (BMI) (p = .024). CAK and KAP were independently predicted by total procedure time (p < .001), BMI (p < .001), total stent length (p = .035 and p = .015), and type IV obstruction (p = .020 and p = .034). CONCLUSION: Radiation exposure during unilateral iliofemoral CVO intervention increases with lesion severity. CVO type IV, BMI, total stent length, and procedure time were independently associated with radiation dose.
引用
- Barbati ME, Yan Y, Avgerinos ED, et al. Radiation Exposure during Recanalisation of Chronic Unilateral Iliofemoral Venous Obstruction Based on Anatomical Classification. Eur J Vasc Endovasc Surg. 2026. PMID: 42019877. doi:10.1016/j.ejvs.2026.04.025
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。