聚合物环密封支架用于不适合开放手术的短颈腹主动脉瘤患者
结论认为该支架对短颈且不适合开放手术的患者是合理选择,5年生存率低于标准EVAR但动脉瘤相关死亡率相当。
要点
- 4年满意密封率89%,瘤囊回缩率62%,平均再干预率2.5%。
- 仅1例死于AAA破裂,5年生存率低于标准EVAR但动脉瘤相关死亡率相当。
核心结论
- 聚合物环密封支架为不适合开放手术且颈条件不良的腹主动脉瘤患者提供了合理选择。
- 该队列5年生存率低于标准EVAR,但动脉瘤相关死亡率似乎相当。
研究设计与样本
- 回顾性纳入2015年以来所有经多学科团队评估不适合开放手术、使用聚合物环密封支架行EVAR并完成5年随访的患者。
主要发现
- 第1、2、3、4、5年总年死亡率分别为5.4%、9%、5.3%、0%、24%。
- 4年时89%的患者获得满意密封,62%的患者瘤囊回缩。
- 平均再干预率为2.5%。
- 2例1型内漏经肢体延伸和/或栓塞治疗,1例因感染需取出支架,仅1例于修复后5年死于AAA破裂。
临床怎么用
- 对于短颈或锥形颈且不适合开放手术的AAA患者,可考虑使用聚合物环密封支架行EVAR。
- 需注意该人群5年生存率低于标准EVAR,应加强随访和患者选择。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Standard endovascular aneurysm repair (EVAR) is recommended for patients "less fit" for open surgical approach but still have a reasonable life expectancy. The use of polymer ring sealing stents (ovation and ALTO) has increased since 2015 to cater for short and conical abdominal aortic aneurysm (AAA) necks with small access vessels. We reviewed the performance of those stents in the "less fit" group. METHODS: All patients with multidisciplinary team outcome (not fit for open repair) who underwent EVAR using polymer ring sealing stents since 2015 were included with completed 5 years follow-up. Clinical and radiological data were collected for patient demographics, AAA characteristics, aneurysm sac stability and/or regression, AAA rupture, surgical conversion, stent-graft complications, secondary intervention and overall survival. RESULTS: Sixty-three patients who were not fit for open repair were offered polymer sealing stents. Thirty-day mortality was (1.6%). The overall annual mortality rate for year 1, 2, 3, 4 and 5 was 5.4%, 9%, 5.3%, 0%, and 24%, respectively. Satisfactory seal was achieved in 89% of the patients at 4 years with sac regression in 62% of the patients. The average reintervention rate was 2.5%. There were 2 cases of type 1 endoleak treated with limb extension and/or embolization. One patient required explantation due to infection. Only 1 patient died from AAA rupture 5 years postrepair. CONCLUSION: Polymer ring sealing stents offer a reasonable option for patients deemed not fit for open repair with "hostile neck." Unsurprisingly, the 5-year survival in this cohort is less than standard EVAR but aneurysm-related mortality seems comparable.
引用
- Elsayed Y, Bakheet M, Ahmed N, et al. Polymer Ring Sealing Stents for Abdominal Aortic Aneurysms with "Hostile Neck" Feature: A Safe Alternative for Patients "Less Fit" for Open Repair. Ann Vasc Surg. 2026. PMID: 41967670. doi:10.1016/j.avsg.2026.03.039
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。