文献速递主动脉疾病

形状记忆聚合物填塞腹主动脉瘤囊后囊体积回归评估

Evaluation of sac volume regression after aortic aneurysm sac embolization with shape memory polymer plugs in patients undergoing endovascular aneurysm repair.
PubMed 文献 · J Vasc Surg · 2026-04-22

结果显示SMP组1年囊回归>10%比例显著更高(79% vs 51%,P<.01),多变量分析中SMP治疗与囊回归独立相关(OR 4.13 [1.5-12.0],P<.01)。

要点

  • EVAR联合SMP预防性囊填塞与标准EVAR相比1年囊回归率更高。
  • SMP治疗是囊回归的独立相关因素(OR 4.13)。
  • 填塞物距通畅分支血管更短与囊回归独立相关。

核心结论

  • 预防性SMP囊填塞与标准EVAR相比,1年囊回归>10%的发生率显著更高。
  • SMP治疗是囊回归的独立相关因素(OR 4.13 [1.5-12.0],P<.01)。

研究设计与样本

  • 多中心回顾性两臂CTA囊回归分析,共97例严格筛选患者。

主要发现

  • EVAR-PSM组1年囊回归>10%发生率为79%,对照组为51%(P<.01)。
  • II型内漏发生率两组分别为40%和49%(P=.4)。
  • 二次再干预率两组分别为2.4%和1.8%(P<.90),无动脉瘤破裂。
  • 1年生存率两组分别为100%和96%(P=.50)。
  • 多变量分析中,SMP治疗与囊回归独立相关(OR 4.13 [1.5-12.0],P<.01)。

关键数值与推荐

  • 囊回归定义为30天至1年CTA之间囊体积减少>10%。
  • EVAR-PSM组平均每例植入59个填塞物,平均填塞密度为129%。
  • 治疗组内,填塞物距通畅分支血管距离更短与囊回归独立相关(OR 0.54 [0.30-0.71],P<.01)。
  • 填塞密度和血栓负荷与囊回归无独立关联。

临床怎么用

  • 对于符合筛选标准的肾下腹主动脉瘤EVAR患者,可考虑预防性SMP囊填塞以促进囊回归。
  • 填塞物应尽量靠近通畅的分支血管放置,以增强囊重塑效果。
  • 仍需监测II型内漏和再干预,尽管本研究两组间无显著差异。

局限性

  • 回顾性研究设计,两组治疗时间窗不同(2019-2023 vs 2014-2019)。
  • 样本量较小(共97例),且患者经过高度筛选。
  • 对照组来自单中心,可能存在选择偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Endovascular aneurysm repair (EVAR) is widely used for infrarenal abdominal aortic aneurysms, offering improved short-term outcomes compared with open repair. However, long-term durability is limited by the need for surveillance and reintervention, often related to sac growth and endoleak. Prophylactic sac embolization using shape memory polymer (SMP) plugs-a porous, bioabsorbable polyurethane scaffold designed to promote thrombosis and tissue ingrowth-has been evaluated in early feasibility studies. This study represents the first global, multicenter real-world analysis of SMP use during EVAR. METHODS: A multicenter, retrospective, two-arm computed tomography angiography (CTA)-based sac regression analysis was performed in 97 highly selected patients meeting prespecified eligibility criteria. Fifty-six patients underwent EVAR with prophylactic sac management (EVAR-PSM) using SMP between 2019 and 2023, including 31 treated prospectively in the abdominal aortic aneurysm-SHAPE early feasibility studies and 25 treated in real-world practice. Forty-one patients underwent standard EVAR between 2014 and 2019 at a single center and met identical inclusion/exclusion criteria, including aneurysm size thresholds, sac volume parameters, infrarenal stent grafts use within instructions for use, serial CTA availability, and exclusion of adjunctive branch vessel embolization. Sac regression (>10% volume reduction between 30-day and 1-year CTA) was assessed. Thrombus burden and patent accessory vessels were analyzed in all patients; packing density and plug proximity to accessory vessels were analyzed in the EVAR-PSM group. RESULTS: Hypertension was more prevalent in controls (98% vs 77%, P = .01), whereas prior myocardial infarction was less common (0% vs 17%, P = .01). In the treatment group, a mean of 59 plugs per patient were implanted, yielding a mean packing density of 129%. Sac regression >10% at 1 year occurred more frequently in the EVAR-PSM group (79% vs 51%, P < .01). Type II endoleak occurred in 40% vs 49% (P = .4), and secondary reintervention rates were similar (2.4% vs 1.8%, P < .90). No aneurysm ruptures occurred. One-year survival was similar between groups (100% vs 96%, P = .50). On multivariable analysis, SMP treatment was independently associated with sac regression (odds ratio: 4.13 [1.5-12.0], P < .01). Within the treatment group, shorter plug distance to patent branch vessels was independently associated with sac regression (odds ratio: 0.54 [0.30-0.71], P < .01), while packing density and thrombus burden were not. CONCLUSIONS: In this multicenter analysis of controlled and real-world data, prophylactic sac embolization with SMP was associated with significantly greater sac regression compared with standard EVAR. Effective sac remodeling appears influenced by plug proximity to branch vessels.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Rao A, Holden A, Reijnen MMPJ, et al. Evaluation of sac volume regression after aortic aneurysm sac embolization with shape memory polymer plugs in patients undergoing endovascular aneurysm repair. J Vasc Surg. 2026. PMID: 42031147. doi:10.1016/j.jvs.2026.03.792

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。