文献速递主动脉疾病颈动脉与弓上血管

单分支支架联合左颈总动脉烟囱技术治疗Zone 1胸主动脉腔内修复术的结局

Outcomes of Zone 1 Thoracic Endovascular Aortic Repair with Single Branched Stent Graft and Left Common Carotid Artery Chimney Stenting for Zone 2 Aortic Arch Pathologies.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2026-04-03

本研究回顾性分析了66例接受单分支联合烟囱支架胸主动脉腔内修复术(scTEVAR)的Zone 2主动脉病变患者,技术成功率91%,中位随访22个月无死亡、卒中或Ia型内漏,免于再干预率1年和3年均为93.8%。结论认为scTEVAR是安全有效的单阶段腔内修复策略,但需更大样本研究确认其耐久性。

要点

  • scTEVAR技术成功率91%,6例因术中风帆效应需近端延长加医生改良开窗。
  • 中位随访22个月无死亡、卒中或Ia型内漏,免于再干预率1年和3年均为93.8%。
  • 左锁骨下动脉分支通畅率1年96.8%、3年94.1%,左颈总动脉支架均通畅。

核心结论

  • scTEVAR是标准化的单阶段腔内主动脉弓修复策略,可实现两支目标血管血运重建并将近端锚定区延伸至Zone 1。
  • 在解剖合适的候选人中,围手术期和2年安全性与有效性令人满意。
  • 需要设计更好的更大队列研究进一步确认其耐久性和安全性。

研究设计与样本

  • 共纳入66例患者(94%男性;中位年龄67岁,IQR 60-72)。
  • 术前评估测量主动脉直径、中心线距离、扭曲度和成角。

主要发现

  • 技术成功率为91%(60/66),其余6例因术中「风帆效应」需近端延长加医生改良开窗,所有附加手术成功。
  • 另1例(2%)发生逆行性A型主动脉夹层,术后第8天接受急诊手术修复。
  • 中位随访22个月(IQR 13-31)期间无死亡、卒中或Ia型内漏。
  • 免于再干预率1年和3年均为93.8%(95%CI 88.3-99.9%)。
  • 左锁骨下动脉分支通畅率1年96.8%(95%CI 92.6-100.0%),3年94.1%(95%CI 87.7-100.0%);左颈总动脉支架随访期间均通畅。

关键数值与推荐

  • 技术成功定义为手术成功完成,具体标准原文未详述。
  • 纳入标准为Zone 2主动脉病变需要近端锚定区延伸至Zone 1。
  • 排除标准原文未报告。

临床怎么用

  • 对于解剖合适的Zone 2主动脉病变需近端锚定至Zone 1的患者,scTEVAR可作为单阶段腔内修复选项。
  • 术中需注意「风帆效应」可能导致需要近端延长加医生改良开窗。
  • 术后需监测逆行性A型主动脉夹层等并发症。

局限性

  • 回顾性观察性设计。
  • 单中心小样本(66例)。
  • 需要更大样本和更好设计的研究确认耐久性和安全性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The aim of this study was to evaluate the safety and efficacy of an innovative, single stage, two target vessel revascularisation endovascular repair strategy, namely single branch and chimney stenting during thoracic endovascular aortic repair (scTEVAR), for zone 2 aortic pathologies requiring proximal sealing in zone 1. METHODS: This was a retrospective, observational cohort study of consecutive patients who underwent scTEVAR at a tertiary Chinese centre between June 2021 and December 2024. Aortic diameter, centreline distance, tortuosity, and angulation were measured for pre-operative assessment. All procedures adhered to established surgical protocols. Outcomes of interest included technical success, death, stroke, type Ia endoleak, re-intervention, and branch patency. Descriptive statistical analyses were performed using R software. RESULTS: Sixty-six patients (94% men; median age 67 years, interquartile range [IQR] 60, 72) were included. The technical success rate was 91% (60 of 66), with the remaining six patients requiring proximal cuff extension with physician modified fenestration due to intra-operative "sail effect". All additional procedures were successful. Another patient (2%) developed retrograde type A aortic dissection and received emergency surgical repair on the eighth post-operative day. There was no death, stroke, or type Ia endoleak during a median follow up of 22 months (IQR 13, 31). Freedom from re-intervention was 93.8% (95% confidence interval [CI] 88.3 - 99.9%) at both one and three year follow up. The left subclavian artery branch patency rate was 96.8% (95% CI 92.6 - 100.0%) at 1 year and 94.1% (95% CI 87.7 - 100.0%) at 3 years. All left common carotid artery stents remained patent during follow up. CONCLUSION: scTEVAR is a standardised and clinically effective single stage endovascular arch repair strategy for zone 2 aortic pathologies, which enables two target vessel revascularisations and proximal sealing zone extension to zone 1. Peri-operative and 2 year safety and efficacy profiles in anatomically suitable candidates were satisfactory. Studies with improved design on larger cohorts are required to further confirm its durability and safety profiles.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Fang J, Cao Z, Zhang Y, et al. Outcomes of Zone 1 Thoracic Endovascular Aortic Repair with Single Branched Stent Graft and Left Common Carotid Artery Chimney Stenting for Zone 2 Aortic Arch Pathologies. Eur J Vasc Endovasc Surg. 2026. PMID: 41936860. doi:10.1016/j.ejvs.2026.03.050

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。