文献速递主动脉疾病

瑞典腹主动脉瘤腔内修复术国家诊断参考水平

National Diagnostic Reference Levels for Endovascular Aneurysm Repair in Sweden.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2026-03-14

该研究基于瑞典血管登记库(Swedvasc)2021至2022年全部EVAR手术数据,提出瑞典EVAR的DAP国家诊断参考水平为152.6 Gy·cm2,并给出完整性和破裂性EVAR的亚组基准值。各中心间辐射剂量差异显著,提示部分中心可基于基准改进辐射常规。

要点

  • 瑞典EVAR的DAP国家DRL为152.6 Gy·cm2,完整性EVAR为147.7 Gy·cm2,破裂性EVAR为213.8 Gy·cm2。
  • 中心层面DAP中位数从28.3 Gy·cm2到212.7 Gy·cm2不等,中心间差异显著。
  • 破裂、髂动脉分支修复、入路并发症、肥胖、低中心手术量和较大动脉瘤是DAP升高的预测因素。

核心结论

  • 提出瑞典EVAR手术DAP的国家诊断参考水平为152.6 Gy·cm2,并为完整性及破裂性EVAR等亚组提供基准DAP值。
  • 各中心间辐射剂量差异明显,提示部分中心可基于基准优化辐射常规。

研究设计与样本

  • 其中完整性腹主动脉瘤831例(89.1%),破裂性腹主动脉瘤102例(10.9%)。
  • 采用多变量分析评估影响透视时间、总剂量面积乘积(DAP)和累积空气比释动能(CAK)的因素。
  • 国家DRL定义为所有中心DAP总中位值的第三四分位数。

主要发现

  • 中心层面EVAR的DAP中位数(IQR)范围为28.3 Gy·cm2(14.1, 76.1)至212.7 Gy·cm2(196.8, 275.0)。
  • 瑞典EVAR总体DAP第三四分位数为152.6 Gy·cm2。
  • 完整性EVAR的DAP中位数为81.1 Gy·cm2,破裂性EVAR为116.5 Gy·cm2(p < .001)。
  • 完整性EVAR的DRL为147.7 Gy·cm2,破裂性EVAR的DRL为213.8 Gy·cm2。
  • 多变量线性回归显示破裂、髂动脉分支修复、入路并发症、肥胖、低中心手术量和较大动脉瘤是EVAR中DAP升高的预测因素。

关键数值与推荐

  • EVAR总体DAP国家DRL:152.6 Gy·cm2。
  • 完整性EVAR的DAP中位数81.1 Gy·cm2,DRL 147.7 Gy·cm2。
  • 破裂性EVAR的DAP中位数116.5 Gy·cm2,DRL 213.8 Gy·cm2。
  • 中心层面DAP中位数最低28.3 Gy·cm2(IQR 14.1, 76.1),最高212.7 Gy·cm2(IQR 196.8, 275.0)。

临床怎么用

  • 可将152.6 Gy·cm2作为瑞典EVAR手术DAP的基准值,用于各中心辐射剂量比较与审计。
  • 对完整性EVAR可参考147.7 Gy·cm2、破裂性EVAR可参考213.8 Gy·cm2进行亚组基准评价。
  • 中心间剂量差异提示高剂量中心可基于基准审视并优化辐射操作常规。
  • 对破裂、髂动脉分支修复、肥胖、较大动脉瘤及低手术量中心应关注辐射剂量管理。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The 2023 European Society for Vascular Surgery (ESVS) guidelines on radiation safety recommended establishment of national diagnostic reference levels (DRLs) for endovascular procedures, which indicate an expected radiation dose for any given procedure for the average sized patient. The aim of this study was to propose a national DRL for Sweden for standard endovascular aortic repair (EVAR). METHODS: This was a national registry based study where all EVARs performed in Sweden over a two year period (2021 - 2022) were identified in the Swedish vascular registry, Swedvasc. Patient demographics were extracted from Swedvasc and radiation related parameters were collected at centre level. Multivariable analyses were performed to assess which factors affected fluoroscopy time, total dose area product (DAP), and cumulative air kerma (CAK). The national DRL was defined as the third quartile of all centre specific median values for DAP total. RESULTS: Nine hundred and thirty-three procedures at 23 centres were included; 831 (89.1%) intact abdominal aortic aneurysms (AAAs) and 102 (10.9%) ruptured AAAs. The median (interquartile range [IQR]) DAP for EVAR at centre level varied from 28.3 Gy·cm2 (IQR 14.1, 76.1) to 212.7 Gy·cm2 (IQR 196.8, 275.0). Overall, the third quartile of the DAP radiation dose for EVAR in Sweden was 152.6 Gy·cm2. The DAP was a median 81.1 Gy·cm2 and 116.5 Gy·cm2 for intact and ruptured EVARs, respectively (p < .001). The DRL was 147.7 Gy·cm2 and 213.8 Gy·cm2 for intact and ruptured EVARs, respectively. In a multivariable linear regression analysis, rupture, iliac branched repair, access complication, obesity, low centre volume and larger aneurysm were predictors for higher DAP during EVAR. CONCLUSION: The current report proposes a DRL for DAP of 152.6 Gy·cm2 for EVAR procedures in Sweden, with specific benchmark DAP values proposed for subgroups of patients. There is a considerable difference in radiation dose between different centres, suggesting a potential for implementation of improved radiation routines in some centres based on benchmarking.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Markusdottir E, Lindén A, Cicek C, et al. National Diagnostic Reference Levels for Endovascular Aneurysm Repair in Sweden. Eur J Vasc Endovasc Surg. 2026. PMID: 41839415. doi:10.1016/j.ejvs.2026.03.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。