二氧化碳血管造影在EVAR术中可能高估II型内漏
该回顾性研究纳入20例择期EVAR的肾下腹主动脉瘤患者,术中同时使用碘对比剂和二氧化碳血管造影检测II型内漏。二氧化碳造影检出率高于碘对比剂(45% vs. 10%,P=0.189),但术后及随访CT均未证实内漏,长期随访无不良后果。
要点
- 二氧化碳造影术中检出II型内漏比例高于碘对比剂,但差异未达统计学显著。
- 二氧化碳检出的II型内漏在术后及随访CT中均未证实,长期随访无临床后果。
- 二氧化碳造影安全,无相关不良事件。
核心结论
- 二氧化碳造影在EVAR术中检出II型内漏的比例高于碘对比剂,但术后影像均未证实且长期随访无不良后果,提示多数为短暂且无血流动力学意义的漏流。
研究设计与样本
- 回顾性分析前瞻性入组的20例肾下腹主动脉瘤行EVAR并术中同时使用碘对比剂和二氧化碳完成造影的患者。
主要发现
- 术中二氧化碳造影在9例患者检出II型内漏,碘对比剂在2例检出(45% vs. 10%,P=0.189)。
- 术后及随访CT扫描均未证实II型内漏。
- 二氧化碳检出II型内漏者下肠系膜动脉直径更大(3.2 mm vs. 2.3 mm,P=0.030),通畅腰动脉更多(中位4 vs. 3,P=0.04)。
- 30天结局为3例再干预、无死亡;中位随访47个月无新发内漏、无再干预、1例死亡。
临床怎么用
- 术中二氧化碳造影检出的II型内漏多无临床意义,不宜据此过度干预,应结合术后影像确认。
局限性
- 样本量小(20例),为回顾性分析,II型内漏检出率差异未达统计学显著。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To evaluate the utility of carbon dioxide (CO2) angiography in the detection of type II endoleak (T2EL) during endovascular treatment of infrarenal abdominal aortic aneurysms (AAAs). METHODS: A retrospective analysis was conducted on a prospectively enrolled 20 consecutive patients with infrarenal AAAs treated with endovascular aneurysm repair (EVAR) and intraoperative completion imaging using both contrast media and CO2. The primary end points were the early intraoperative detection of T2EL and 30-day reintervention and mortality. The secondary end points were the confirmatory diagnosis of T2EL on the first postoperative and follow-up computed tomography (CT) scans, follow-up reinterventions, follow-up mortality, and safety of CO2 angiography. RESULTS: Twenty male patients (median age 71 years) were included. Intraoperative CO2 angiography identified a higher detection rate of T2EL in 9 patients, while iodinated contrast detected T2EL in 2 patients (45% vs. 10%, P 0.189). No T2EL was confirmed on the postoperative and follow-up CT scans. No adverse events related to CO2 angiography were observed. Subgroup analysis revealed patients with CO2-detected T2EL had larger inferior mesenteric artery (IMA) diameters (3.2 mm vs. 2.3 mm, P = 0.030) and more patent lumbar arteries (median 4 vs. 3, P = 0.04), while IMA patency and preoperative largest aortic sac diameter were similar. Thirty-day outcomes were recorded as 3 reinterventions and no mortality. A median follow-up period of 47 months resulted in no newly formed endoleaks, no reinterventions, and 1 mortality. CONCLUSION: CO2 angiography demonstrated a higher intraoperative detection rate of T2ELs during EVAR compared to iodinated contrast. However, none were confirmed on postoperative imaging or led to adverse outcomes during long-term follow-up. These findings suggest that many CO2-detected T2ELs may represent transient, hemodynamically insignificant flow lacking clinical consequence, but may have a future role in evaluating occult or type V endoleaks. Future prospective studies are needed to clarify their clinical relevance.
引用
- Elsaadany NA, Ali AA, ElWakeel H, et al. Carbon Dioxide Angiography in Endovascular Aneurysm Repair May Overestimate the Presence of Type II Endoleak. Ann Vasc Surg. 2026. PMID: 41653965. doi:10.1016/j.avsg.2026.01.024
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。