文献速递主动脉疾病

保留Windkessel功能覆膜支架减轻猪模型TEVAR后左心室重构

Windkessel Preserving Aortic Stent Graft Attenuates Left Ventricular Remodelling after Thoracic Endovascular Aortic Repair in a Porcine Model.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2026-02-16

刚性支架导致降主动脉搏动性降低93%并加速左心室质量增长,而顺应性支架保留局部主动脉顺应性和Windkessel功能,左心室增长与对照组相当,提示顺应性匹配的支架可减轻心脏不良重构。

要点

  • 刚性覆膜支架使降主动脉搏动性降低93%,加速左心室肥厚。
  • 顺应性纳米纤维支架保留局部主动脉顺应性,左心室增长与对照组相当。
  • TEVAR中选择顺应性匹配的支架可能减轻远期心脏重构。

核心结论

  • 传统刚性覆膜支架损害Windkessel功能并促进左心室肥厚,而顺应性支架保留主动脉生物力学并减轻心脏重构。

研究设计与样本

  • 采用纵向心电门控CT血管造影量化主动脉体积、直径搏动性和左心室质量,随访4.3个月。

主要发现

  • 传统刚性覆膜支架组降主动脉搏动性降低93%,左心室质量增长速度为4.83 ± 2.34 g/月,较对照组快约70%。
  • 顺应性纳米纤维覆膜支架组支架段收缩期至舒张期体积和直径比值与基线相似,左心室增长速度为2.80 ± 1.84 g/月,与对照组2.83 ± 2.46 g/月相当。

临床怎么用

  • 在TEVAR中选择顺应性匹配的覆膜支架可能有助于保留Windkessel功能并减轻左心室不良重构。
  • 对于年轻创伤患者等预期寿命较长者,支架顺应性可能是需考虑的因素。

局限性

  • 研究为猪模型,样本量有限(对照组7头、刚性支架组8头、顺应性支架组5头),结果需进一步临床验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) has largely replaced open surgery for aortic pathologies and trauma due to its minimally invasive nature and reduced peri-operative risk. However, conventional stent grafts are significantly stiffer than the native aorta and may impair Windkessel function, promoting adverse cardiac remodelling, particularly in younger trauma patients with longer life expectancies. This study aimed to evaluate the impact of conventional stiff vs. compliant Windkessel preserving stent grafts on aortic biomechanics and left ventricular (LV) remodelling in a swine model of TEVAR. METHODS: Twenty juvenile swine were divided into three groups: seven sham operated controls, eight animals implanted with conventional stiff stent grafts (CS-SG), and five animals implanted with novel compliant nanofibrous stent grafts (NF-SG). Longitudinal cardiac gated computed tomography angiography was used to quantify aortic volumes, diameter pulsatility, and LV mass over 4.3 months. RESULTS: CS-SG implantation resulted in a 93% reduction in aortic pulsatility in the descending thoracic aorta and accelerated LV mass gain (4.83 ± 2.34 g/month), approximately 70% faster than controls. In contrast, NF-SG preserved local aortic compliance and maintained Windkessel function, with systolic to diastolic volume and diameter ratios in the stented segment similar to baseline. LV growth in the NF-SG group (2.80 ± 1.84 g/month) was comparable with controls (2.83 ± 2.46 g/month), indicating attenuation of adverse remodelling. CONCLUSION: CS-SG impair Windkessel function and promote LV hypertrophy, while compliant stent grafts preserve aortic biomechanics and mitigate cardiac remodelling. These findings highlight the importance of compliance matched endografts in TEVAR patients and support further development of Windkessel preserving technologies.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Kamenskiy A, Kuniyil S, Shahbad R, et al. Windkessel Preserving Aortic Stent Graft Attenuates Left Ventricular Remodelling after Thoracic Endovascular Aortic Repair in a Porcine Model. Eur J Vasc Endovasc Surg. 2026. PMID: 41708050. doi:10.1016/j.ejvs.2026.02.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。