B型主动脉夹层TEVAR术中支架诱导的内膜-内膜套叠
研究总结了SAoII的影像学特征及处理方式,发现所有患者均通过追加支架移植物得到血管内处理,中位随访51.5个月无主动脉相关死亡。
要点
- TEVAR术中SAoII罕见但可能致命,需及时识别特征性影像。
- SAoII常见影像特征包括移植物漂浮、内膜层套叠及内膜/导丝/输送系统移位。
- 所有SAoII患者通过追加支架移植物进行血管内处理,随访无主动脉相关死亡。
核心结论
- SAoII是TEVAR术中或术后罕见但可能致命的医源性并发症,血管内干预可有效处理该急性并发症。
- 及时准确识别决定性影像特征(如移植物漂浮、内膜套叠)是成功治疗的关键。
研究设计与样本
- 回顾性多中心观察性分析,注册号ChiCTR2300073780。
- SAoII定义为TEVAR导致术中主动脉内膜部分或环形撕裂,排除自然疾病进展所致。
主要发现
- SAoII发生于急性期8/20、亚急性期11/20、慢性期1/20。
- 影像特征:内膜/导丝/输送系统移位8例(40%),移植物漂浮17例(85%),内膜层套叠13例(65%),真腔闭塞及内脏动脉丢失3例(15%),无内膜隔的单腔3例(15%)。
- SAoII发生时机:支架移植物释放后12/20(60%),输送系统引入后4/20(20%),超硬导丝引入后4/20(20%)。
- 所有SAoII患者均通过追加支架移植物血管内处理,中位随访51.5个月无主动脉相关死亡。
关键数值与推荐
- SAoII定义:TEVAR导致术中主动脉内膜部分或环形撕裂,排除自然疾病进展所致。
- 影像特征判定:内膜/导丝/输送系统移位、移植物漂浮、内膜层套叠、真腔闭塞及内脏动脉丢失、无内膜隔的单腔。
临床怎么用
- TEVAR术中及术后应警惕SAoII,注意识别移植物漂浮、内膜套叠等影像特征。
- 一旦发生SAoII,可考虑追加支架移植物进行血管内处理。
局限性
- 回顾性观察性设计,样本量有限(20例SAoII)。
- 仅纳入三个中心,可能存在选择偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Stent graft induced aortic intimo-intimal intussusception (SAoII) during thoracic endovascular aortic repair (TEVAR) of type B aortic dissection (TBAD) is a rare complication. This study aimed to report reliable imaging features of SAoII to avoid such a potentially catastrophic event. This retrospective, multicentre observational analysis was registered as a Chinese Clinical Trial (ChiCTR2300073780). METHODS: Patients undergoing TEVAR for TBAD in three centres were reviewed from January 2014 to December 2022. SAoII was defined as intra-procedural partial or circumferential disruption of the aortic intima because of TEVAR, excluding those created by natural disease progression. The imaging features and management of SAoII were summarised. RESULTS: 1 643 patients undergoing TEVAR for TBAD were reviewed. Among them, SAoII was observed in 20 patients (mean age, 44.5 ± 11.8 years; 16 men). TEVAR was performed in the acute phase (8 of 20), subacute phase (11 of 20), or chronic phase (1 of 20). Imaging features including displacement of the intima, wire, or delivery system were observed in eight (40%), floating endograft in 17 (85%), intussusception of the intima layer in 13 (65%), true lumen occlusions and visceral artery loss in three (15%), and a single lumen without intimal septa in three (15%) patients. SAoII was observed in 60% (12 of 20) after deployment of the stent graft, in 20% (4 of 20) after introduction of a stent graft delivery system, and in 20% (4 of 20) after the introduction of a super stiff wire. All patients who developed SAoII were endovascularly managed by an additional stent graft; no aortic related death was observed among these patients with SAoII during the median follow up of 51.5 months. CONCLUSION: SAoII is a rare but potentially fatal iatrogenic complication during or after TEVAR; endovascular interventions could be effective to manage this acute complication. Timely and accurate identification of decisive imaging features are key to successful treatment.
引用
- Jiang X, Fu W, Lu W, et al. Intimo-Intimal Intussusception during Endovascular Repair of Type B Aortic Dissection. Eur J Vasc Endovasc Surg. 2026. PMID: 41679455. doi:10.1016/j.ejvs.2026.02.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。