文献速递主动脉疾病

现货型胸腹多分支内假体TAMBE治疗EVAR后IA型内漏的早期结果

Early Outcomes of Off-the-Shelf Thoracoabdominal Multibranch Endoprosthesis for Type IA Endoleak from Failed Infrarenal and Complex Endovascular Aortic Repairs.
PubMed 文献 · Ann Vasc Surg · 2026-01-12

本研究回顾性分析了单中心2020年4月至2025年2月共10例因肾下腹主动脉EVAR或复杂EVAR失败后出现IA型内漏而接受TAMBE救援性修复的患者。技术成功率100%,无围手术期死亡,30天再干预率10%。TAMBE是治疗既往EVAR失败后IA型内漏的有前景的救援性主动脉修复选择,但需更长期随访。

要点

  • TAMBE救援性修复EVAR后IA型内漏技术成功率100%,无围手术期死亡。
  • 30天再干预率10%,1例因分支闭塞行右肾动脉球囊扩张及支架植入。
  • 既往EVAR失败至TAMBE的中位间隔为7年,平均年龄80.6岁,最大动脉瘤直径86 mm。

核心结论

  • TAMBE是治疗既往肾下腹主动脉EVAR和复杂EVAR失败后IA型内漏的有前景的救援性主动脉修复选择,具有优异的手术和围手术期结局。

研究设计与样本

  • 单中心回顾性研究,纳入2020年4月至2025年2月期间接受TAMBE的10例因既往EVAR失败后IA型内漏行救援性修复的患者。
  • 收集基线特征、术中指标和30天结局。

主要发现

  • 既往EVAR失败至TAMBE的中位间隔为7年,3例曾尝试修复IA型内漏。
  • 总体平均年龄80.6岁,最大动脉瘤直径86 mm,肾旁动脉瘤最常见。
  • 既往失败的EVAR装置包括肾下EVAR 8例、单烟囱EVAR 1例和三血管Zenith开窗支架1例。
  • 术中指标:手术时间259 min,透视时间59.8 min,造影剂用量109 mL。
  • 技术成功率100%,无围手术期死亡,30天再干预率10%(1例因分支闭塞行右肾动脉球囊扩张及支架植入)。

临床怎么用

  • 对于既往肾下腹主动脉EVAR或复杂EVAR失败后出现IA型内漏的患者,可考虑使用TAMBE进行救援性修复。
  • 需注意分支闭塞风险,本组30天再干预率为10%。

局限性

  • 样本量小(10例),为单中心回顾性研究。
  • 随访时间短,仅报告30天结局,长期耐久性尚未确定。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The Thoracoabdominal Multibranch Endoprosthesis (TAMBE) is the first off-the-shelf four-vessel inner-branched endograft to obtain commercial approval for complex abdominal and thoracoabdominal aortic aneurysms. While off-label TAMBE has been applied to type IA endoleak from failed endovascular aortic repair (EVAR), there is paucity of data regarding outcomes involving this construct. Here, we present early outcomes on rescue TAMBE for type IA endoleak from failed infrarenal and complex EVARs. METHODS: A retrospective review of patients who received TAMBE at a single institution from April 2020 to February 2025 was performed. Baseline characteristics, intraoperative metrics, and 30-day outcomes were examined. RESULTS: Ten patients who received rescue TAMBE for failed EVAR were included. The median interval between failed EVAR and TAMBE was 7 years. Three patients underwent previous attempts at type IA endoleak repair. Overall average age was 80.6 years and maximum aneurysm diameter was 86 mm. Pararenal aneurysms were the most common aneurysm type. Failed previous EVAR devices included infrarenal EVAR (8), single snorkel EVAR (1), and three-vessel Zenith fenestrated (1). Intraoperative metrics included operative time of 259 min, fluoroscopy time of 59.8 min, and contrast usage of 109 mL. Technical success was 100% with no perioperative mortalities. Thirty-day reintervention rate was 10%. This patient required right renal artery angioplasty and stenting due to branch occlusion. CONCLUSION: TAMBE is a promising option for rescue aortic repair of previously failed infrarenal and complex EVAR, with excellent procedural and perioperative outcomes. Longer-term follow-up and larger studies are ongoing to define its durability and broader applicability.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Han K, Zenilman A, Pyun AJ, et al. Early Outcomes of Off-the-Shelf Thoracoabdominal Multibranch Endoprosthesis for Type IA Endoleak from Failed Infrarenal and Complex Endovascular Aortic Repairs. Ann Vasc Surg. 2026. PMID: 41534711. doi:10.1016/j.avsg.2026.01.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。