文献速递主动脉疾病

分支型腔内主动脉修复中专用球囊扩张桥接支架的短期 outcomes

Short Term Outcomes of a Dedicated Balloon Expandable Bridging Stent in Branched Endovascular Aortic Aneurysm Repair.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2025-12-29

技术成功率为99.3%,中位随访17个月,1年和2年分支一期通畅率分别为98.3%和95.8%,二期通畅率分别为99.2%和98.4%,30天死亡率为6.0%。结论认为BGP+桥接支架短期结果满意,需更长期随访确认。

要点

  • BGP+桥接支架在BEVAR中技术成功率达99.3%。
  • 1年和2年分支一期通畅率分别为98.3%和95.8%。
  • 30天死亡率为6.0%,靶血管不稳定率为2.9%。

核心结论

  • BEVAR使用BGP+桥接支架的短期结果非常满意,但需更长期随访确认。

主要发现

  • 技术成功率为99.3%(分支水平)。
  • 中位随访17个月(四分位距10-35个月),1年和2年分支一期通畅率分别为98.3%(标准误0.3)和95.8%(标准误0.7),共56例闭塞。
  • 1年和2年分支二期通畅率分别为99.2%(标准误0.2)和98.4%(标准误0.3)。
  • 靶血管不稳定率为2.9%,包括7例Ic型内漏、1例3b型内漏和2例3c型内漏。
  • 总体30天死亡率为6.0%;1年和2年免于分支相关再干预率分别为99.3%(标准误0.2)和98.4%(标准误0.3)。

临床怎么用

  • BGP+桥接支架在BEVAR中短期通畅率和免于再干预率较高,可作为肾内脏动脉分支的桥接选择。

局限性

  • 回顾性设计,随访时间较短(中位17个月),需更长期数据确认结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: This study aimed to report the short term outcomes of the BeGraft Peripheral Plus (BGP+) bridging stent graft following branched endovascular aortic repair (BEVAR) of thoraco-abdominal and complex abdominal aortic aneurysms. METHODS: All consecutive patients treated in six high-volume centers with BEVAR incorporating at least one branch for the renovisceral arteries (outer branches) and who received at least one BGP+ as a bridging stent graft were included and data retrospectively analyzed. RESULTS: A total of 2 418 target visceral vessels in 729 patients undergoing BEVAR were bridged with a BGP+. Technical success was achieved in 99.3% of branches. The median follow up was 17 months (interquartile range 10, 35 months). The estimated one and two year branch primary patency was 98.3% (standard error [SE] 0.3) and 95.8% (SE 0.7), respectively, with a total of 56 occlusions. The estimated one and two year branch secondary patency was 99.2% (SE 0.2) and 98.4% (SE 0.3), respectively. The target vessel instability rate was 2.9%, with seven type Ic endoleaks (T1cELs), one type 3b EL, and two type 3c ELs. The overall 30 day mortality rate was 6.0%. Additional unplanned stents were deployed in 268 of 2 418 target visceral vessels owing to vessel dissection (n = 4), need for extended seal (n = 185), vessel angulation (n = 73), vessel perforation (n = 5), or T1cEL (n = 1). The estimated one and two year freedom from branch related re-intervention was 99.3% (SE 0.2) and 98.4% (SE 0.3), respectively. CONCLUSION: BEVAR performed with BGP+ bridging stents is associated with very satisfactory short term outcomes. Longer follow up is required to confirm these promising results.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Caputo S, Jakimowicz T, Abisi S, et al. Short Term Outcomes of a Dedicated Balloon Expandable Bridging Stent in Branched Endovascular Aortic Aneurysm Repair. Eur J Vasc Endovasc Surg. 2025. PMID: 41475432. doi:10.1016/j.ejvs.2025.12.049

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。