假腔封堵器对慢性B型主动脉夹层腔内修复术后主动脉重塑的影响
回顾性单中心研究纳入71例慢性B型主动脉夹层患者,在TEVAR或开窗/分支修复术中植入第三代假腔封堵器(FLO)。随访显示主动脉及假腔体积显著下降、真腔扩大,83.1%患者发生主动脉重塑,辅助栓塞与真腔扩大及FLO重塑相关且未增加死亡或并发症。
要点
- FLO植入后主动脉及假腔体积随时间显著下降,真腔体积扩大。
- 辅助栓塞与真腔扩大及FLO重塑显著相关,未增加死亡或并发症。
- FLO重塑与假腔缩小强相关,可能作为手术成功的影像学标志。
核心结论
- FLO植入为慢性B型主动脉夹层提供持久的主动脉重塑,辅助栓塞通过消除残余灌注增强重塑效果且不增加风险。
- 无脊髓缺血发生及FLO重塑作为成功替代标志,突显该联合低风险策略对长期主动脉稳定的价值。
研究设计与样本
- 回顾性单中心研究纳入71例慢性B型主动脉夹层患者,中位年龄64岁(四分位距58-70岁),77.5%为男性。
- 患者于2018年6月至2024年12月期间在TEVAR或开窗/分支修复术中植入第三代FLO。
- 使用Aquarius软件三维重建量化主动脉、真腔(TL)和假腔(FL)体积。
主要发现
- 共268次影像检查,主动脉总体积和FL体积随时间显著下降,TL体积扩大(均P < .001)。
- 中位主动脉总体积从1个月时796 cm3降至4年时706 cm3,FL体积从501 cm3降至296 cm3,TL体积从287.5 cm3增至358 cm3。
- 中位随访13.3个月(四分位距5.6-36.5个月),83.1%患者发生主动脉重塑,FL稳定占12.7%,扩大占4.2%。
- 年轻患者(P = .048)及基线直径和体积较小者(P = .043和P = .034)重塑更常见。
- 辅助栓塞与TL扩大(χ2 = 5.8;P = .016)和FLO重塑(χ2 = 5.2;P = .022)强相关,与主动脉重塑呈趋势(χ2 = 4.8;P = .056),未增加死亡或并发症。
关键数值与推荐
- 主动脉重塑定义为FL体积较基线减少≥10%,稳定为±10%变化,扩大为>10%增加。
- FLO重塑定义为随访影像上封堵器受压呈新月形。
- FLO重塑与同期FL缩小强相关(χ2 = 20.8;P < .001)。
- FLO尺寸(≥40 mm vs <40 mm)和位置(胸部、膈肌或腹部)不影响结局。
- 无脊髓缺血病例发生。
临床怎么用
- 对于慢性B型主动脉夹层行TEVAR或开窗/分支修复的患者,可考虑辅助FLO植入以促进主动脉重塑。
- 辅助栓塞可增强重塑效果,且未增加死亡或并发症,可作为低风险联合策略。
- FLO重塑可作为影像学标志用于评估手术成功和随访。
局限性
- 回顾性单中心研究,样本量有限(71例)。
- 中位随访时间较短(13.3个月),长期结果需进一步验证。
- FLO重塑与主动脉重塑的关联为趋势性(P = .056),需更大样本确认。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate morphological and clinical outcomes after false lumen occluder (FLO) implantation for postdissection thoracoabdominal aortic aneurysm and to investigate the impact of adjunctive false lumen embolization on aortic remodeling. METHODS: A retrospective single-center study included 71 patients (median age, 64 years; interquartile range, 58-70 years; 77.5% male) with chronic type B aortic dissection treated between June 2018 and December 2024 with third-generation FLO implantation during thoracic endovascular aortic repair (TEVAR) or fenestrated/branched repair. Aortic, true lumen (TL), and false lumen (FL) volumes were quantified using three-dimensional reconstructions on Aquarius software. FLO remodeling was defined as compression of the occluder with a crescent shape on follow-up imaging. Aortic remodeling (FL regression) was defined as a ≥10% reduction in FL volume, stability as ±10% change, and enlargement as >10% increase compared with baseline. Associations between clinical, anatomical, and procedural variables and remodeling outcomes were analyzed using nonparametric and mixed effects models. RESULTS: Across 268 imaging examinations, total aortic and FL volumes decreased significantly over time, whereas the TL volume expanded (all P < .001). The median total aortic volume declined from 796 cm3 at 1 month to 706 cm3 at 4 years, and the FL volume decreased from 501 cm3 to 296 cm3, whereas TL volume increased from 287.5 cm3 to 358 cm3. Median follow-up was 13.3 months (interquartile range, 5.6-36.5 months). Aortic remodeling occurred in 83.1% of patients, FL stability in 12.7%, and enlargement in 4.2%. Regression was more frequent in younger patients (P = .048) and those with smaller baseline diameters and volumes (P = .043 and P = .034). Adjunctive embolization was strongly associated with TL expansion (χ2 = 5.8; P = .016) and FLO remodeling (χ2 = 5.2; P = .022), and showed a trend toward increased aortic remodeling (χ2 = 4.8; P = .056) without added mortality or morbidity. No cases of spinal cord ischemia occurred. FLO size (≥40 mm vs <40 mm) and position (thoracic, diaphragmatic, or abdominal) did not influence outcomes. FLO remodeling was strongly correlated with concurrent FL reduction (χ2 = 20.8; P < .001) and may represent a radiologic marker of procedural success. CONCLUSIONS: FLO implantation provided durable aortic remodeling in chronic type B aortic dissection, and adjunctive embolization enhanced remodeling efficacy by eliminating residual perfusion without increasing risk. The absence of spinal cord ischemia and the identification of FLO remodeling as a surrogate of success highlight the value of this combined, low-risk strategy for long-term aortic stability.
引用
- Giuffrè G, Pennetta FF, Palmier M, et al. Impact of false lumen occluders on aortic remodeling after endovascular repair of chronic type B dissection. J Vasc Surg. 2026. PMID: 41512935. doi:10.1016/j.jvs.2026.01.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。