运动诱发电位监测在开放胸腹主动脉瘤修复术中的准确性与适用性
该回顾性病例系列分析纳入2000至2024年间在两个学术转诊中心接受择期开放胸腹主动脉瘤修复术并接受运动诱发电位(MEP)监测的464例患者。结果显示,术中MEP显著改变者108例(23.3%),其中99例(91.7%)经增加脊髓灌注措施后恢复,未恢复的9例均发生急性截瘫;MEP稳定者无急性脊髓缺血,但5.1%发生迟发性截瘫。术毕无MEP信号对急性脊髓缺血的灵敏度、特异度及阴性、阳性预测值均为100%。
要点
- 术毕无MEP信号对急性脊髓缺血预测灵敏度、特异度及阴性阳性预测值均达100%。
- 术中MEP显著改变后经增加脊髓灌注措施,91.7%(99/108)可恢复。
- MEP稳定者无急性脊髓缺血,但5.1%仍发生与术后血流动力学不稳相关的迟发性截瘫。
核心结论
- 在规范操作和兼容麻醉方案下,MEP监测是检测开放胸腹主动脉瘤修复术中急性脊髓缺血的优良方法,并显著影响预防急性脊髓缺血的决策。
- 迟发性脊髓缺血仍是重要问题,可能无法仅通过MEP改变检测,主要归因于术后因素。
研究设计与样本
- 回顾性病例系列研究,分析2000至2024年间在两个学术转诊中心接受择期开放胸腹主动脉瘤修复术并接受MEP监测的464例患者。
- 所有手术由同一主刀外科医生完成,采用相同的神经生理学方案。
- 临床显著MEP改变定义为腿-臂比值持续下降超过50%。
- 术后神经学结局分为急性、迟发性或不确定性脊髓缺血。
主要发现
- 临床显著MEP改变发生于108例(23.3%),其中99例(91.7%)在术中采取增加脊髓灌注措施后恢复。
- 所有9例MEP未恢复患者均发生急性截瘫。
- 356例MEP稳定患者中无急性脊髓缺血发生,但18例(5.1%)发生与术后血流动力学不稳相关的迟发性截瘫。
- 急性脊髓缺血发生率为1.9%(9/464),任何形式脊髓缺血(急性、迟发性或不确定性)发生率为7.7%(36/464)。
- 术毕无MEP信号对急性脊髓缺血的灵敏度、特异度、阴性预测值和阳性预测值均为100%。
关键数值与推荐
- 临床显著MEP改变定义为腿-臂比值持续下降超过50%。
- 术后神经学结局分为急性、迟发性或不确定性脊髓缺血。
临床怎么用
- 在开放胸腹主动脉瘤修复术中,应规范执行MEP监测并采用兼容的麻醉方案,以可靠检测急性脊髓缺血。
- 术中出现临床显著MEP改变时,应及时采取增加脊髓灌注的术中措施以促进MEP恢复、预防急性截瘫。
- 术毕无MEP信号提示急性脊髓缺血高风险,需强化围术期决策。
- MEP稳定不能排除迟发性脊髓缺血风险,术后需关注血流动力学稳定性。
局限性
- 本研究为回顾性病例系列设计。
- 研究仅纳入两个学术转诊中心且由同一主刀外科医生完成手术,结果外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Spinal cord ischaemia (SCI) is a devastating risk in open thoraco-abdominal aortic aneurysm (TAAA) repair, making the reliable detection and prevention of neurological injury a clinical priority. The objective of this study was to evaluate the accuracy and clinical utility of motor evoked potential (MEP) monitoring in predicting and preventing SCI during open TAAA repair. METHODS: This retrospective case series study analysed 464 patients who underwent elective TAAA repair with MEP monitoring across two academic referral centres between 2000 and 2024. All procedures were performed by the same lead surgeon with an identical neurophysiological protocol. Clinically significant MEP changes were defined as a consistent decrease in leg to arm ratio by more than 50%. Post-operative neurological outcomes were categorised as acute, delayed, or uncertain SCI. RESULTS: Clinically significant MEP changes occurred in 108 patients (23.3%), with recovery achieved in 99 cases (91.7%) following intra-operative measures to increase spinal cord perfusion. All nine patients without MEP recovery developed acute paraplegia. Among 356 patients with stable MEPs, none developed acute SCI, although 18 (5.1%) experienced delayed paraplegia associated with post-operative haemodynamic instability. The acute SCI rate was 1.9% (nine of 464), and any form of SCI (acute, delayed, or uncertain) occurred in 7.7% of cases (36 of 464). The absence of MEP signals at the end of the operation demonstrated 100% sensitivity, 100% specificity, and 100% negative and positive predictive values for acute SCI. CONCLUSION: MEP monitoring is an excellent method, providing a proper execution and a compatible anaesthetic protocol, for detecting acute peri-operative SCI and greatly influences decision making to prevent acute SCI during open TAAA procedures, although delayed SCI remains an important factor that may not be detected by MEP changes alone, largely owing to factors occurring post-operatively.
引用
- Frankort J, Mess WH, Krabbe J, et al. Accuracy and Applicability of Motor Evoked Potential Monitoring during Open Thoraco-Abdominal Aortic Aneurysm Repair. Eur J Vasc Endovasc Surg. 2026. PMID: 41490667. doi:10.1016/j.ejvs.2025.12.058
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。