聚酯主体覆膜支架联合PTFE髂支在FEVAR中的中期结果
本研究评估开窗腔内主动脉修复(FEVAR)中,在聚酯分叉主体对侧使用短扩张器头端PTFE髂支的可行性和中期结果。30例患者(中位年龄77岁)纳入,技术成功率高,中位随访24个月无肢体相关不良事件或再干预,所有髂支保持通畅,肢体与主体袖套重叠无显著变化。
要点
- FEVAR中聚酯主体联合PTFE髂支中期安全可行。
- 无肢体相关不良事件、再干预或靶血管闭塞。
- 支架重叠长度和百分比无显著变化。
核心结论
- FEVAR中聚酯分叉主体联合PTFE髂支的中期结果良好,无肢体相关不良事件、再干预或显著重叠变化。
研究设计与样本
- 单中心回顾性研究,纳入2020年6月至2023年7月期间30例接受FEVAR并使用PTFE髂支(对侧于聚酯分叉主体)的患者,中位年龄77(70,79)岁。
主要发现
- 中位随访24(12,30)个月,无肢体相关临床不良事件或再干预,所有髂支保持通畅。
- 髂支与分叉主体袖套重叠的中位绝对变化为-0.1 mm(-0.8,1.1),百分比变化为-0.4%(-2.7,4)。
- FEVAR的2年估计一期和二期临床成功率分别为86±7%和90±6%,生存率为83±7%。
临床怎么用
- 在FEVAR中,对侧髂支可考虑使用短扩张器头端的PTFE覆膜支架与聚酯分叉主体组合,以获得稳定的中期结果。
局限性
- 样本量小(30例),为单中心回顾性研究,需更大规模队列及不同组件组合的比较分析验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The aim of this study was to evaluate the feasibility and mid-term results of combining polytetrafluoroethylene (PTFE)-based iliac limbs, having a short dilator tip, with a polyester (Dacron)-based bifurcated component during a fenestrated endovascular aortic repair (FEVAR). MATERIALS AND METHODS: All patients who underwent a FEVAR procedure in a single tertiary center were screened for inclusion in the study. Data were collected retrospectively and all imaging was reviewed for the study. The criterion for inclusion in the study was the implantation of a PTFE-based iliac limb endoprosthesis at the contralateral side of the polyester-based bifurcated component during a FEVAR procedure landing in a native common iliac artery. The primary study endpoints were technical success, adverse events, and reinterventions related to limbs, migration between contralateral iliac limbs and bifurcated components, type Ib and IIIa endoleaks, and iliac limb patency. RESULTS: A total of 30 patients with a median age of 77 (70, 79) years, who underwent FEVAR procedures from June 2020 to July 2023, were included in the study. The total number of target vessels was 116, and the majority (N = 24) of patients received 4 fenestrations. Technical success was achieved for the iliac limb in all patients, and for the FEVAR, it was obtained in 29 cases (97%). Median follow-up was 24 (12, 30) months. There were no clinical limb-related adverse events or reinterventions. At the end of the follow-up period, all limbs remained patent. The median absolute and percentual change in overlap between the limb and the cuff of the bifurcated endograft was of -0.1 mm (-0.8, 1.1) and -0.4% (-2.7, 4), respectively. The estimated primary, secondary clinical success of the FEVAR, and survival rates (± standard error) at 2 years were 86 ±7%, 90±6, and 83±7%, respectively. CONCLUSIONS: The present study demonstrated promising mid-term outcomes, with the absence of limb-related adverse events, reinterventions, and any significant change in the overlap of PTFE iliac limbs combined with polyester bifurcated device during FEVAR. Further validation in a larger cohort as well as comparative analysis between different component combinations are needed to confirm the findings of the present study.Clinical ImpactThis study underscores the feasibility and excellent mid-term clinical outcomes of combining PTFE-based iliac limbs with a short dilator tip and a polyester-based bifurcated component during fenestrated endovascular aortic repair. The absence of significant migration and adverse effects related to the iliac limbs, along with the lack of target vessel occlusions, suggests a potential advantage of using a delivery system that avoids crossing the fenestrations, thereby enhancing technical success and ensuring stable and durable results over time.
引用
- Tasopoulou KM, Karelis A, Jirström W, et al. Mid-Term Outcomes of PTFE-Based Contralateral Iliac Limbs in Polyester-Based Fenestrated Bifurcated Endografts. J Endovasc Ther. 2026. PMID: 41518339. doi:10.1177/15266028251409061