文献速递外周动脉疾病

球囊尺寸与踝下血管成形术临床结局的关联

Association Between Balloon Size and Clinical Outcomes After Inframalleolar Angioplasty for Chronic Limb-Threatening Ischemia.
PubMed 文献 · Ann Vasc Surg · 2025-11-13

这项多中心回顾性研究纳入230例接受踝下球囊血管成形术的慢性肢体威胁性缺血患者,按球囊直径≥2.5 mm(44例)或<2.5 mm(186例)分组。倾向性评分匹配后1年无截肢生存率和伤口愈合率无显著差异,但大球囊组无靶病变血运重建率显著更高。

要点

  • 球囊直径≥2.5 mm与1年无靶病变血运重建率更高相关。
  • 严重中膜动脉钙化是靶病变血运重建的危险因素。
  • 球囊尺寸对无截肢生存率和伤口愈合率无显著影响。

核心结论

  • 踝下血管成形术中使用直径≥2.5 mm球囊与1年无靶病变血运重建率更高相关。

研究设计与样本

  • 多中心回顾性研究纳入2018年1月至2022年8月间230例接受踝下球囊血管成形术的慢性肢体威胁性缺血患者。
  • 按球囊直径≥2.5 mm(44例)或<2.5 mm(186例)分组,并进行倾向性评分匹配分析。

主要发现

  • 倾向性评分匹配识别35对患者,1年无截肢生存率两组分别为76.1%与70.6%(P=0.72),无显著差异。
  • 1年伤口愈合率两组分别为71.5%与60.0%(P=0.76),无显著差异。
  • 1年无靶病变血运重建率大球囊组显著更高(79.4% vs. 45.7%;P=0.004)。
  • 多因素分析显示球囊直径≥2.5 mm是无靶病变血运重建的预测因素(HR 0.18;95%CI 0.06-0.56;P=0.003)。
  • 严重中膜动脉钙化是靶病变血运重建的危险因素(HR 5.9;95%CI 1.13-30.9;P=0.04)。

临床怎么用

  • 在踝下血管成形术中,可考虑使用直径≥2.5 mm的球囊以降低靶病变血运重建风险。
  • 对合并严重中膜动脉钙化的患者应加强监测和随访。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Vessel diameter measured by intravascular ultrasound (IVUS) in inframalleolar (IM) lesions is larger than the balloon size commonly used in practice. It remains unclear which patients receive balloons comparable to IVUS-reported sizes and whether this affects outcomes. METHODS: We conducted a retrospective, multicenter study of 230 patients with chronic limb-threatening ischemia (CLTI) who underwent IM balloon angioplasty between January 2018 and August 2022. Patients were divided into two groups: those who underwent angioplasty with balloon size ≥2.5 mm, comparable to vessel diameters reported in previous IVUS studies (n = 44), and those treated with smaller balloon size <2.5 mm (n = 186). One-year outcomes, including amputation-free survival (AFS), wound healing, and freedom from target lesion revascularization (TLR), were compared. Propensity score matching (PSM) analysis was conducted. RESULTS: PSM identified 35 pairs. At 1 year, there were no significant differences in AFS (76.1% vs. 70.6%; P = 0.72) or wound healing rates (71.5% vs. 60.0%; P = 0.76) between the two groups. However, the large balloon group had a significantly higher freedom from TLR rate (79.4% vs. 45.7%; P = 0.004). Multivariate analysis identified balloon diameter ≥2.5 mm as a predictor of freedom from TLR (hazard ratio [HR], 0.18; 95% confidence interval [CI], 0.06-0.56; P = 0.003) and severe medial arterial calcification as a risk factor for TLR (HR, 5.9; 95% CI, 1.13-30.9; P = 0.04). CONCLUSION: The use of balloons with a diameter ≥2.5 mm, comparable to vessel sizes reported in previous IVUS studies, was associated with a higher 1-year freedom from TLR in CLTI patients undergoing IM angioplasty.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。