混合弹簧圈在2区TEVAR左锁骨下动脉栓塞中的应用
本研究回顾性分析2个高容量主动脉中心连续37例使用Penumbra Occlusion Device(POD)行左锁骨下动脉栓塞的2区TEVAR患者。POD栓塞技术成功率达97%,30天CTA显示24%存在Ic型内漏,随访临床成功率92%,无卒中或短暂性脑缺血发作。POD是2区TEVAR中左锁骨下动脉栓塞的有效工具。
要点
- POD栓塞左锁骨下动脉技术成功率达97%,无Ic型内漏证据。
- 30天CTA显示24%患者存在Ic型内漏,多数自行缓解或保守处理。
- 随访临床成功率92%,无卒中或短暂性脑缺血发作报告。
核心结论
- POD是2区TEVAR中左锁骨下动脉栓塞的有效工具,技术成功率高且短期结果可接受。
研究设计与样本
- 回顾性研究,纳入2个高容量主动脉中心连续37例使用POD行左锁骨下动脉栓塞的2区TEVAR患者,68%为男性,中位年龄70岁。
主要发现
- 49%的病例部署单个POD,81%经肱动脉入路,68%使用4F鞘管;其余病例额外部署1枚弹簧圈以获得血管造影闭塞。
- 左锁骨下动脉栓塞技术成功率达97%,最终造影无Ic型内漏证据。
- 30天CTA显示9例(24%)存在Ic型内漏:2例需再次介入弹簧圈栓塞,4例自行缓解,3例保守处理且主动脉病变无进展。
- 随访时左锁骨下动脉栓塞临床成功率为92%,无卒中或短暂性脑缺血发作报告;所有解剖外旁路、左椎动脉和远端左锁骨下动脉均保持通畅。
临床怎么用
- POD可通过小口径入路可控部署,可能简化手术并减少永久闭塞高流量血管所需的弹簧圈数量。
- POD可作为传统弹簧圈或血管封堵器栓塞的替代选择,用于2区TEVAR中左锁骨下动脉栓塞。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Prevertebral left subclavian artery (LSA) occlusion was traditionally performed using conventional coil embolization or vascular plugs. The Penumbra Occlusion Device (POD) is a hybrid coil specifically designed for embolizing high-flow vessels. This study aims to report the technical and clinical success of the POD for LSA embolization during Zone 2 Thoracic Endovascular Aortic Repair (TEVAR). MATERIALS & METHODS: All consecutive patients who underwent LSA embolization using the POD in Zone 2 TEVAR in 2 high-volume aortic centers were retrospectively collected and analyzed. Procedural data and clinical outcomes were collected. The primary endpoint was the technical success rate of LSA embolization using the POD. Secondary endpoints included short-term outcomes and freedom from reintervention. Follow-up was performed with Computed Tomography Angiography (CTA) to confirm successful LSA prevertebral embolization without type Ic endoleak and to assess patency of surgical revascularization of the distal LSA. RESULTS: Between January 2020 and April 2024, 37 patients (68% men, median age: 70 years) with degenerative chronic thoracic aortic disease or acute aortic syndromes were included. A single POD was deployed in 49% of cases, primarily via brachial access (81%) using a 4F introducer sheath (68%). In the remaining cases, 1 additional coil was deployed to obtain angiographic occlusion. Technical success of LSA embolization was achieved in 97% of cases, with no evidence of type Ic endoleak on final angiography. At 30-day CTA, 9 patients (24%) had type Ic endoleak: 2 required reintervention with coiling, 4 resolved spontaneously, and 3 were managed conservatively without progression of aortic pathology. Clinical success of LSA embolization at follow-up was 92%, with no reported strokes or transient ischemic attacks. All extra-anatomical bypasses, left vertebral arteries, and distal LSAs remained patent. CONCLUSION: The POD is an effective tool for LSA embolization during TEVAR. This occlusion system offers a promising alternative to traditional methods by overcoming anatomical limitations, potentially eliminating the need for large introducers in upper extremity access and reducing the number of coils required for permanent occlusion of a high-flow vessel.Clinical ImpactThe Penumbra Occlusion Device (POD) represents a practical alternative to conventional coil or plug embolization for large, high-flow vessels. Its design allows controlled deployment through small-caliber access, potentially simplifying the procedure and reducing the number of devices required. This study demonstrates high technical success and acceptable short-term outcomes, suggesting that the POD can achieve reliable left subclavian artery occlusion during Zone 2 TEVAR. These results may guide procedural planning and support wider adoption of the POD as a feasible option in this setting.
引用
- Cambiaghi M, Isernia G, Ongaro D, et al. Hybrid Coils for Left Subclavian Artery Embolization During Zone 2 Thoracic Endovascular Repair. J Endovasc Ther. 2025. PMID: 41222301. doi:10.1177/15266028251384929
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。