文献速递主动脉疾病内脏/肾动脉与血管畸形

间隙导向(GPS)技术:全股动脉开窗腔内主动脉修复中困难肾内脏分支插管的辅助方法

Gap Steering (GPS) Technique: An Adjunct for Challenging Renovisceral Branch Cannulation in Total Transfemoral Fenestrated Endovascular Aortic Repair.
PubMed 文献 · J Endovasc Ther · 2025-11-12

该研究回顾性分析42例使用医生改良支架行开窗腔内主动脉修复的患者,评估间隙导向(GPS)技术处理因开窗错位导致困难靶血管插管的可行性与结局。GPS组18根靶血管中14根(77.8%)插管成功,无GPS相关并发症;GPS后组患者技术成功率和靶血管稳定性显著优于GPS前组。

要点

  • GPS技术是使用可控鞘在支架与主动脉壁间制造间隙的纯股动脉辅助插管方法。
  • GPS组18根困难靶血管插管成功率77.8%,无GPS相关并发症。
  • GPS后组患者技术成功率和靶血管稳定性显著优于GPS前组。

核心结论

  • GPS技术是使用医生改良支架行开窗腔内主动脉修复时处理困难插管的可行辅助方法。
  • 该技术避免额外器械,尤其适合使用现有可控鞘完成全股动脉修复。

研究设计与样本

  • 回顾性研究,纳入2020年10月至2025年1月42例(14例胸腹、28例复杂腹主动脉瘤)使用医生改良支架行开窗腔内主动脉修复并放置桥接支架的患者。
  • 按治疗时期分层:GPS前技术组10例(30根靶血管),GPS后技术组32例(114根靶血管)。
  • GPS技术在GPS后组作为困难插管的主要补救措施,114根靶血管中选择性应用于18根(15.8%)困难血管。

主要发现

  • 18根接受GPS技术的靶血管中14根(77.8%)插管成功,无GPS技术相关并发症。
  • 患者水平:GPS后组技术成功率显著更高(96.8% vs 60.0%,p=0.008),靶血管成功率更高(100% vs 80.0%,p=0.052),靶血管不稳定率显著更低(3.1% vs 30.0%,p=0.03)。
  • 血管水平:GPS后组靶血管技术成功率更高(100% vs 93.3%,p=0.042),靶血管闭塞率更低(0.0% vs 6.7%,p=0.042),靶血管不稳定率更低(0.9% vs 13.3%,p=0.007)。
  • 所有接受GPS技术治疗的血管在中位14个月随访时保持通畅。

临床怎么用

  • 对于因开窗错位导致困难肾内脏靶血管插管的患者,可考虑使用GPS技术作为纯股动脉入路的辅助插管策略。
  • GPS技术利用市售可控鞘在开窗-主动脉壁界面进行定向导丝操作,无需额外入路或器械修改。

局限性

  • 本研究为回顾性设计,非对照研究,样本量有限。
  • GPS技术仅在部分困难靶血管中选择性应用,存在选择偏倚可能。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Fenestrated Endovascular Aortic Repair (F-EVAR) using Physician-Modified Endografts (PMEGs) has become an important option in the treatment of complex aortic aneurysms, particularly when custom-made devices are not available. However, difficult target vessel (TV) cannulations, notably with misalignment, often limit total transfemoral repair. To address this condition, we developed the Gap Steering (GPS) technique, which is a transfemoral-only adjunctive method using a steerable sheath to create a controlled gap between the stent graft and the aortic wall, enabling on-demand cannulation. In this study, we aimed to evaluate the technical feasibility and procedural features, outcomes, and risks associated with the GPS technique in difficult target vessel cannulation owing to fenestration misalignment. METHODS: We retrospectively reviewed 42 patients (14 thoracoabdominal, 28 complex abdominal aortic aneurysms) undergoing F-EVAR using PMEGs with bridging stent placement between October 2020 and January 2025. Although not designed as a comparative study, patients were stratified by treatment period: Pre-GPS technique group (n = 10, TV = 30) and Post-GPS technique group (n = 32, TV = 114). The GPS technique was used as the primary bailout for difficult cannulations in the Post-GPS technique group. Among the 114 TVs, the GPS technique was selectively applied to 18 challenging vessels (15.8%). RESULTS: Among 18 target vessels treated with the GPS technique, successful cannulation was achieved in 14 (77.8%), with no GPS technique-related complications. At the per patient level, the Post-GPS technique group showed significantly higher technical success (96.8% vs 60.0%, p=0.008) and a higher target vessel success rate (100% vs 80.0%, p=0.052). TV instability was significantly lower (3.1% vs 30.0%, p=0.03). At the per-vessel level, TV technical success was higher (100% vs 93.3%, p=0.042), with lower rates of TV occlusion (0.0% vs 6.7%, p=0.042) and TV instability (0.9% vs 13.3%, p=0.007). All GPS technique-treated vessels remained patent at the 14 month median follow-up. CONCLUSION: The GPS technique is a feasible adjunct for difficult cannulations in F-EVAR using PMEGs. It avoids additional devices and is particularly suited for total transfemoral repair using currently available steerable sheaths.Clinical ImpactDifficult renovisceral target vessel cannulation remains a major limitation to achieving total transfemoral F-EVAR using physician-modified endografts (PMEGs). This challenge often necessitates upper-extremity access or complex adjunctive maneuvers, increasing procedural invasiveness and access-related risks. The Gap Steering (GPS) technique offers a practical adjunctive strategy using a commercially available steerable sheath to achieve controlled directional guidewire manipulation at the fenestration-aortic wall interface. It enables selective cannulation without additional access routes, larger delivery systems, or device modification. This reproducible and fully transfemoral approach has the potential to improve procedural efficiency and expand the applicability of PMEG-based F-EVAR in complex aortic repair.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Yagami T, Hashizume K, Kasai M, et al. Gap Steering (GPS) Technique: An Adjunct for Challenging Renovisceral Branch Cannulation in Total Transfemoral Fenestrated Endovascular Aortic Repair. J Endovasc Ther. 2025. PMID: 41220330. doi:10.1177/15266028251388731

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。