文献速递主动脉疾病内脏/肾动脉与血管畸形

医师改良腔内移植物加外分支矫正开窗偏移

Physician-Modified Custom Made Endograft Adding an Outer Branch to Correct a Fenestration Offset.
PubMed 文献 · J Endovasc Ther · 2025-11-05

本文描述一例80岁男性症状性80 mm近肾动脉瘤患者,紧急使用为其他患者设计的开窗定制腔内移植物(CMD),其中左肾动脉开窗较血管开口低15 mm,通过将6 mm覆膜支架(Viabahn)侧端缝合于开窗创建逆行外分支,手术成功且术后恢复平稳,出院前CT确认靶血管通畅且无内漏。

要点

  • 紧急情况下可对现有开窗CMD进行医师改良,加外分支矫正开窗偏移。
  • 左肾动脉开窗低15 mm时,用6 mm Viabahn侧端缝合创建逆行外分支。
  • 术后靶血管通畅且无内漏,提示该改良技术可行。

核心结论

  • 紧急情况下可能需要进一步改良现有CMD,包括在开窗支架中整合分支以适应患者解剖。
  • 未来标准化改良技术可能进一步扩大其应用。

研究设计与样本

  • 本文为技术描述,报告一例80岁男性症状性80 mm近肾动脉瘤的紧急处理。

主要发现

  • 使用为另一患者设计的开窗CMD,4个开窗中3个与靶血管对齐,左肾动脉开窗较血管开口低15 mm。
  • 将6 mm覆膜支架(Viabahn)侧端缝合于开窗创建逆行外分支,手术成功且术后经过平稳。
  • 出院前CT确认靶血管通畅且无内漏。

临床怎么用

  • 在缺乏合适即用型选项的紧急情况下,可考虑对现有开窗CMD进行医师改良加外分支。
  • 使用现有CMD而非新建PMEG可减少准备时间和操作复杂性。

局限性

  • 本文为单例技术报告,未报告样本量、随访时长或长期结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To describe the use of a physician-modified endograft (PMEG) through the incorporation of an outer branch within a fenestrated custom-made device (CMD) originally designed for another patient with similar anatomy. TECHNIQUE: An 80-year-old male, with a symptomatic 80 mm juxtarenal aneurysm, was managed urgently using a readily available fenestrated CMD, designed for a different patient. While 3 of the 4 fenestrations were appropriately aligned with the intended target vessels (TVs), the fourth fenestration, targeting the left renal artery, was incorporated 15 mm lower than the vessel's orifice. To overcome this offset, a 6 mm covered stent (Viabahn, Gore & Associates, Flagstaff, Arizona) was latero-terminal sutured to the fenestration, creating a retrograde outer branch. The procedure was successful, followed by an uneventful postoperative course. Predischarge computed tomography confirmed the patency of the TV and the freedom from endoleak. CONCLUSION: Urgent setting may demand further modifications of readily available CMD, including the incorporation of branches in fenestrated stent grafts, in order to accommodate in patient's anatomy. Future standardization of the modification techniques may further expand their utilization.Clinical ImpactThis case introduces a physician-modified endograft technique incorporating an outer branch into pre-existing fenestrated custom-made device (CMD) for urgent complex aortic aneurysm repair. Using an available CMD instead of creating a new PMEG reduces preparation time and procedural complexity while maintaining technical success and target vessel patency. This practical, repoducible approach broadens the applicability of fenestrated technology in urgent settings lacking suitable off-the-shelf options.

来源:J Endovasc Ther,查看原文。版权归原作者所有。

引用

  1. Torri L, Nana P, Torrealba JI, et al. Physician-Modified Custom Made Endograft Adding an Outer Branch to Correct a Fenestration Offset. J Endovasc Ther. 2025. PMID: 41190438. doi:10.1177/15266028251384208

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。