文献速递外周动脉疾病

FIB-5指数对接受血管内介入的外周动脉疾病患者2年不良结局的预后价值

Prognostic Value of the Fibrosis-5 Index for Predicting 2-Year Adverse Outcomes in Patients With Peripheral Artery Disease Undergoing Endovascular Intervention.
PubMed 文献 · Ann Vasc Surg · 2025-10-14

该研究纳入537例外周动脉疾病(PAD)接受血管内治疗的患者,按FIB-5三分位分组,随访平均657天。校正传统危险因素后,FIB-5独立预测主要不良心血管事件(MACE,HR 1.62,95%CI 1.29-1.88)和主要不良肢体事件(MALE,HR 1.47,95%CI 1.22-1.83),ROC分析显示对MACE和MALE的区分能力良好,且优于FIB-4。结论认为FIB-5基于常规实验室检查,可用于术前风险分层。

要点

  • FIB-5独立预测PAD介入术后2年MACE和MALE。
  • FIB-5对MACE的AUC为0.895,对MALE的AUC为0.815,优于FIB-4。
  • FIB-5完全基于常规实验室指标,便于术前风险分层。

核心结论

  • FIB-5由常规实验室检查衍生,对PAD血管内治疗后的MACE和MALE具有预后价值。
  • 将FIB-5纳入术前风险分层可能有助于识别高危患者并指导二级预防和随访强度。
  • 需要在独立的多中心PAD队列中验证。

研究设计与样本

  • 回顾性队列研究,筛选823例连续PAD患者,经预设排除后分析537例。
  • 平均随访657天,患者按FIB-5三分位分层。
  • FIB-5按Maeda公式基于白蛋白、血小板计数、碱性磷酸酶和AST/ALT比值计算,同时计算FIB-4。
  • 共同主要结局为24个月时的MACE(心血管死亡、非致死性心肌梗死、非致死性卒中)和MALE(大截肢或靶肢体血运重建)。
  • 采用多变量Cox模型和ROC分析评估预后性能。

主要发现

  • 较高的FIB-5值与更大的合并症负担和更复杂的病变相关。
  • 校正传统危险因素后,FIB-5独立预测MACE(HR 1.62,95%CI 1.29-1.88)。
  • 校正传统危险因素后,FIB-5独立预测MALE(HR 1.47,95%CI 1.22-1.83)。
  • ROC分析显示FIB-5对MACE区分能力良好(AUC 0.895,95%CI 0.831-0.921)。
  • ROC分析显示FIB-5对MALE区分能力良好(AUC 0.815,95%CI 0.761-0.839),优于FIB-4。

关键数值与推荐

  • FIB-5按Maeda公式计算,纳入白蛋白、血小板计数、碱性磷酸酶和AST/ALT比值。
  • FIB-5预测MACE的HR为1.62(95%CI 1.29-1.88),预测MALE的HR为1.47(95%CI 1.22-1.83)。
  • FIB-5预测MACE的AUC为0.895(95%CI 0.831-0.921),预测MALE的AUC为0.815(95%CI 0.761-0.839)。

临床怎么用

  • 可利用常规实验室指标计算FIB-5,在PAD血管内治疗术前识别MACE和MALE高危患者。
  • 对FIB-5较高的患者可考虑加强二级预防和随访强度。

局限性

  • 研究为单中心回顾性设计,经预设排除后仅分析537例,可能存在选择偏倚。
  • 结论需在独立的多中心PAD队列中进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To evaluate the prognostic role of the Fibrosis-5 (FIB-5) index in patients with peripheral artery disease (PAD) undergoing endovascular therapy. METHODS: We screened 823 consecutive PAD patients and analyzed 537 after prespecified exclusions (mean follow-up 657 days). Patients were stratified into FIB-5 tertiles. FIB-5 incorporates routine laboratories-albumin, platelet count, alkaline phosphatase, and the aminotransferase/alanine aminotransferas ratio-per the Maeda formula; the FIB-4 index was also computed from baseline labs. Co-primary outcomes were major adverse cardiovascular events (MACE: cardiovascular death, nonfatal myocardial infarction, nonfatal stroke) and major adverse limb events (MALE: major amputation or target-limb revascularization) at 24 months. Prognostic performance was assessed with multivariable Cox models and receiver operating characteristic (ROC) analysis. RESULTS: Higher FIB-5 values were associated with greater comorbidity burden and more complex lesions. After adjustment for conventional risk factors, FIB-5 independently predicted MACE (hazard ratio [HR] 1.62, 95% confidence interval [CI] 1.29-1.88) and MALE (HR 1.47, 95% CI 1.22-1.83). ROC analysis showed good discrimination for MACE (area under the curve [AUC] 0.895, 95% CI 0.831-0.921) and MALE (AUC 0.815, 95% CI 0.761-0.839), outperforming FIB-4. CONCLUSION: FIB-5, derived entirely from routine laboratory tests, is prognostic for both MACE and MALE after endovascular treatment for PAD. Incorporation into preprocedural risk stratification may help identify higher-risk patients and guide secondary prevention and follow-up intensity. Confirmation in independent, multicenter PAD cohorts is warranted.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Dereli S, Ürkmez M, Sağlam MK, et al. Prognostic Value of the Fibrosis-5 Index for Predicting 2-Year Adverse Outcomes in Patients With Peripheral Artery Disease Undergoing Endovascular Intervention. Ann Vasc Surg. 2025. PMID: 41101641. doi:10.1016/j.avsg.2025.09.057

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。