文献速递主动脉疾病

新型阶梯球囊在开窗腔内主动脉修复中缩短手术时间并减少辐射暴露

Impact of a new stepped balloon for bridging stent implantation on procedural time and radiation exposure in fenestrated endovascular aortic repair.
PubMed 文献 · J Vasc Surg · 2025-08-26

该回顾性研究纳入60例接受四开窗FEVAR的患者共240个目标血管,比较标准球囊 bridging stent 与新型阶梯球囊 bridging stent 的手术时间和辐射暴露。结果显示阶梯球囊组总支架置入时间中位数11.3分钟,显著短于两个标准球囊组(17.4和20.2分钟,P<.001),总剂量面积乘积也显著更低(4.6 vs 9.3和11.4 Gy cm2,P=.001),且各目标血管透视时间均减少(P<.001)。技术成功率均为100%,并发症无显著差异,阶梯球囊组喇叭口直径更大。

要点

  • 阶梯球囊 bridging stent 联合可调弯鞘可显著缩短FEVAR总支架置入时间(11.3 vs 17.4/20.2分钟)。
  • 阶梯球囊组总剂量面积乘积显著更低(4.6 vs 9.3/11.4 Gy cm2),各目标血管透视时间均减少。
  • 技术成功率三组均为100%,30天随访所有目标血管通畅,仅1例(0.4%)因腹腔干支架断裂行早期再干预。

核心结论

  • 在FEVAR中使用阶梯球囊 bridging stent 联合可调弯鞘可显著减少支架置入时间和辐射暴露,同时保持手术安全性并改善喇叭口特征。

研究设计与样本

  • 回顾性研究,纳入2020年3月至2025年3月在高容量主动脉中心接受四开窗FEVAR的60例患者共240个目标血管。
  • 患者分为三组:标准球囊BeGraft联合预载肾动脉导管(n=20)、标准球囊BeGraft联合可调弯鞘(n=20)、阶梯球囊BeFlared联合可调弯鞘(n=20)。

主要发现

  • 阶梯球囊组总支架置入时间中位数11.3分钟(IQR 10.9-12),显著短于标准球囊两组(17.4和20.2分钟,P<.001)。
  • 阶梯球囊组总支架置入剂量面积乘积为4.6 Gy cm2,显著低于标准球囊两组的9.3和11.4 Gy cm2(P=.001)。
  • 所有目标血管的透视时间在阶梯球囊组均减少(P<.001)。
  • 阶梯球囊组各目标血管喇叭口直径更大(腹腔干P=.002;肠系膜上动脉P=.002;右肾动脉P≤.001;左肾动脉P=.126)。
  • 三组技术成功率均为100%,并发症发生率无显著差异;1个月CT显示所有目标血管通畅,1例(1/236,0.4%)因腹腔干支架断裂行早期再干预。

临床怎么用

  • 对于接受四开窗FEVAR的复杂主动脉修复患者,可考虑使用阶梯球囊 bridging stent 联合可调弯鞘以缩短支架置入时间并降低辐射暴露。

局限性

  • 本研究为单中心回顾性研究,样本量有限(60例),需进一步前瞻性多中心研究确认这些有利的早期结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To evaluate the impact of a new dedicated stepped balloon-mounted bridging stent (BS) on procedural time, radiation exposure, and early technical outcomes in patients undergoing fenestrated endovascular aortic repair (FEVAR). METHODS: A retrospective study was conducted on patients treated with four-fenestration FEVAR at a high-volume aortic center between March 2020 and March 2025. Patients were categorized into three groups: standard balloon BS (BeGraft, BG, Bentley) and renal access with preloaded renal catheters, BG and renal access with steerable sheaths, and stepped balloon BS (BeFlared, Bentley) and renal access with steerable sheaths. All procedures were recorded. Primary end points included stenting time and radiation exposure (dose, dose area product, fluoroscopy time) for all four target vessels (TVs), and specifically for each TV. Secondary end points included intraoperative complications, flaring characteristics, and 30-day outcomes. Postoperative computed tomography imaging-assessed BS positioning, sealing, and flaring diameters. RESULTS: In total, 60 patients with 240 TVs were included. The stepped balloon stepped balloon BS group (n = 20) showed significantly shorter median total stenting time (11.3 minutes; interquartile range [IQR], 10.9-12 minutes) compared with both standard balloon BG groups (n = 20 in each group) (17.4 minutes and 20.2 minutes; P < .001). Total stenting DAP was also significantly lower with the stepped balloon (4.6 Gy cm2 vs 9.3 and 11.4 Gy cm2; P = .001). Fluoroscopy time was reduced in all TVs (P < .001). Flaring diameters were larger in the stepped balloon group across all TV (celiac trunk P = .002; superior mesenteric artery P = .002; right renal artery P ≤ .001; and left renal artery P = .126). Technical success was 100% in all groups, with no significant difference in complication rates. One-month computed tomography scans showed patency of all TV; one BS (1/236 [0.4%]) early reintervention was performed for a celiac trunk stent fracture, with an arcuate ligament found on the preoperative computed tomography scan. CONCLUSIONS: The use of BSs with stepped balloons and steerable sheaths in FEVAR significantly reduced stenting time and radiation exposure while preserving procedural safety and improving flaring characteristics. These findings suggest procedural streamlining and potential clinical advantages of this new generation BS during complex aortic repair. Further prospective, multicenter studies are warranted to confirm these favorable early outcomes.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Pennetta FF, Palmier M, Laporte L, et al. Impact of a new stepped balloon for bridging stent implantation on procedural time and radiation exposure in fenestrated endovascular aortic repair. J Vasc Surg. 2025. PMID: 40876581. doi:10.1016/j.jvs.2025.08.027

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。