文献速递主动脉疾病

开窗EVAR术中平扫锥形束CT可减少结构缺陷导致的二次干预

Plain cone beam computed tomography during fenestrated endovascular aortic repair minimizes secondary interventions due to structural defects.
PubMed 文献 · J Vasc Surg · 2025-08-12

本研究回顾性分析了234例开窗EVAR患者,评估术中平扫锥形束CT(CBCT)识别结构缺陷的价值。术中CBCT发现17%患者存在显著结构缺陷,其中多数与靶血管桥接支架相关。常规使用术中平扫CBCT能识别并即时纠正超过三分之二的结构缺陷,但完全消除因结构缺陷导致的二次干预仍有挑战。

要点

  • 术中平扫CBCT可识别17%开窗EVAR患者的显著结构缺陷,多数位于靶血管。
  • 常规使用CBCT能即时纠正超过三分之二的结构缺陷,减少二次干预。
  • 术后仍有8%患者存在显著结构缺陷,部分在回顾时可见于CBCT。

核心结论

  • 常规术中平扫CBCT能识别并即时纠正超过三分之二的开窗EVAR结构缺陷,但完全消除因结构缺陷导致的二次干预仍具挑战。

主要发现

  • 术中40例(17%)共45处临床显著结构缺陷,多数与靶血管桥接支架相关(n=38)。
  • 术后18例(8%)共21处临床显著结构缺陷,多数累及靶血管(n=8),其中3例有症状(1例肾动脉闭塞,2例下肢跛行)。
  • 18例术中未诊断缺陷中,回顾性复阅CBCT发现11例(61%)缺陷可见;5例图像质量不足,2例缺陷在CBCT视野外。

临床怎么用

  • 开窗EVAR术中常规使用平扫CBCT有助于即时发现并纠正结构缺陷,减少因缺陷导致的二次干预。

局限性

  • 回顾性设计,单中心经验,部分缺陷因图像质量或视野限制未能识别。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Structural defects during fenestrated endovascular aortic repair (FEVAR) can be difficult to identify only on two-dimensional imaging. This study aims to assess the potential additional value of routine intraoperative completion plain cone-beam computed tomography (CBCT) in identifying such defects during FEVAR. METHODS: We conducted a retrospective review of all consecutive FEVARs performed at a tertiary aortic center between January 2013 and December 2022. Patients with intraoperative plain CBCT and at least one postoperative computed tomography angiography were selected. Baseline characteristics, operative data and follow-up data were collected. All imaging was re-reviewed for the purpose of the study. End points included clinically significant structural defects on CBCT and postoperative computed tomography angiography and postoperative reinterventions. Data are presented as median and interquartile range or number (%). RESULTS: Of the 271 patients treated with FEVAR during the study period, 234 were included in the analysis (197 male, 72 years old (range, 68-77 years), 219 [94%] elective repairs). A median of four fenestrations (range, 3-4 fenestrations) were incorporated into the main body. Intraoperatively, 40 patients (17%) had a total of 45 clinically significant structural defects identified on CBCT, mostly related to target vessel bridging stents (n = 38). Postoperatively, 18 patients (8%) had 21 clinically significant structural defects, again mostly involving target vessels (n = 8). Three of these were symptomatic, including one renal artery occlusion and two cases of lower limb claudication. Among the 18 patients with intraoperatively undiagnosed defects, retrospective re-review of the CBCT revealed that the findings had been visible in 11 cases (61%). In five cases, image quality was insufficient, and in two cases the defect was outside the CBCT field of view. CONCLUSIONS: The routine use of intraoperative plain CBCT enabled the identification and immediate correction of more than two-thirds of all structural defects during FEVAR; however, it remains challenging to completely eliminate secondary interventions owing to structural defects. Further improvements can be expected with more detailed CBCT analysis and improvements in imaging quality and increasing the field of view.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Berczeli M, Jirström W, Mohammed Y, et al. Plain cone beam computed tomography during fenestrated endovascular aortic repair minimizes secondary interventions due to structural defects. J Vasc Surg. 2025. PMID: 40812692. doi:10.1016/j.jvs.2025.08.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。