机器人腹腔干结扎治疗胸腹主动脉瘤腔内隔绝术后II型内漏
本文报告一例胸腹主动脉瘤采用定制T-branch支架腔内隔绝后,因腹腔干来源的II型内漏,在开放手术高危且腔内选项因解剖标准被排除的情况下,采用机器人腹腔干结扎联合术中吲哚菁绿注射排除内脏缺血,获得极佳结果。文献中尚未报道腹腔干机器人结扎治疗II型内漏。
要点
- II型内漏是腹主动脉瘤腔内修复术后最常见并发症,通常仅在瘤囊增大>10 mm时干预。
- 胸腹主动脉瘤腔内隔绝术后II型内漏发生率研究不足,腹腔干来源者治疗方式多样。
- 对多次腔内手术的高危复杂胸腹主动脉瘤患者,机器人腹腔干结扎是创新微创多学科替代方案。
核心结论
- 机器人腹腔干结扎联合术中吲哚菁绿注射可成功治疗胸腹主动脉瘤腔内隔绝术后腹腔干来源的II型内漏。
研究设计与样本
- 单病例报告,患者为胸腹主动脉瘤行定制T-branch支架腔内隔绝术后出现腹腔干来源II型内漏。
主要发现
- 患者被评估为开放手术高危,腔内选项因解剖标准被排除,遂行机器人腹腔干结扎。
- 术中注射绿色吲哚菁绿排除内脏缺血,获得极佳结果。
- 文献中已有肠系膜下动脉或腰动脉机器人结扎的病例,但腹腔干机器人结扎治疗II型内漏尚未见报道。
关键数值与推荐
- II型内漏通常在瘤囊较初始增大>10 mm时才随访干预。
临床怎么用
- 对开放手术高危且腔内选项因解剖标准被排除的胸腹主动脉瘤腔内隔绝术后II型内漏患者,可考虑机器人腹腔干结扎作为多学科微创替代方案。
- 术中可注射绿色吲哚菁绿评估内脏灌注以排除缺血。
局限性
- 单病例报告,结论的外推性有限。
- 胸腹主动脉瘤腔内隔绝术后II型内漏的发生率研究不足。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Type II endoleak represents the most frequent complication after endovascular abdominal aortic aneurysm repair. Usually it is followed up and treated only in cases of aneurysmal sac enlargement >10 mm respect to the beginning. The incidence of this type of endoleak after para-renal and thoraco-abdominal aortic aneurysm (TAAA) aneurysms endovascular exclusion is underinvestigated. Modalities of treatment are well described in the current guidelines. Our patient had a type II endoleak from the celiac trunk after TAA aneurysm exclusion with a custom made T-branch endograft: he was judged at high risk for open repair; endovascular options were excluded for anatomical criteria, so based on the experience of the general surgeon of our hospital we opted for the robotic ligature of the celiac trunk, excluding visceral ischemia with intraoperative injection of green indocyanine, obtaining a very excellent result. In the current literature is reported some case of inferior mesenteric artery or lumbar arteries robotic ligature but celiac trunk robotic ligature to treat type II endoleak has never been reported to date.Clinical ImpactType II endoleaks after endovascular exclusion of TAAA are underinvestigated, especially for those from the celiac trunk, and there are different modalities of treatment. For complex TAAA in patients already submitted to multiple endovascular procedures, the Robotic ligation of the Celiac Trunk to exclude the endoleak represents an innovative and less invasive multidisciplinary approach that can offer a valid alternative with success. In addition the technique used in our center and described in our case has been not yet described in the current literature and represents a very important innovation.
引用
- Massara M, Alberti A, Parlongo G, et al. Successful Celiac Trunk Robotic Ligature to Treat a Type II Endoleak After Thoracoabdominal Aneurysm Endovascular Exclusion. J Endovasc Ther. 2025. PMID: 40772436. doi:10.1177/15266028251363464
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。