腹主动脉瘤腔内修复术中预防性瘤囊栓塞的1年结果
本研究回顾性分析两个中心2022年2月至2024年1月接受EVAR并使用形状记忆聚合物(SMP) plugs进行预防性瘤囊栓塞的肾下腹主动脉瘤患者,29例有1年影像数据。结果显示无内漏、无再干预、无手术相关不良事件,瘤囊体积和直径均出现退缩,提示该方法安全有效。
要点
- 预防性瘤囊栓塞在EVAR术中安全可行,无围手术期死亡或不良事件。
- 1年随访无内漏、无再干预,55%患者瘤囊直径退缩,45%稳定。
- SMP plugs可生物降解且CT伪影小,可能优于弹簧圈或液体栓塞剂。
核心结论
- 预防性瘤囊栓塞在EVAR术中是诱导瘤囊血栓形成安全有效的方法,1年随访显示高瘤囊退缩率、无内漏且无需再干预。
研究设计与样本
- 回顾性研究,纳入两个中心2022年2月至2024年1月接受肾下腹主动脉瘤EVAR并使用SMP plugs的患者,29例有1年影像数据。
主要发现
- 1年时无内漏、无再干预、无术中不良安全事件、无围手术期死亡。
- 瘤囊体积中位变化为退缩17%(IQR 7%-33%),直径中位变化为退缩6 mm(IQR -10 mm至-1 mm)。
- 1年直径分析:55%(16例)退缩,45%(13例)稳定,无扩张。
- 体积分析中,退缩患者有67%显示瘤囊体积退缩>10%。
临床怎么用
- 对于接受EVAR的肾下腹主动脉瘤患者,可考虑术中预防性使用SMP plugs进行瘤囊栓塞以促进瘤囊血栓形成和退缩。
局限性
- 回顾性设计,样本量较小(29例),仅1年随访数据,需更长期数据确认结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Aneurysm sac behavior has been associated with long-term survival and reinterventions, spurring an interest in more active management of the aneurysm sac during endovascular aortic repair (EVAR). We therefore investigated the utility of sac embolization with shape memory polymer (SMP) plugs (Shape Memory Medical), a novel, biodegradable, nonartifact-producing implant inserted into the aneurysm sac between the graft and vessel wall to promote sac thrombosis and regression. METHODS: We retrospectively studied all patients undergoing EVAR of infrarenal aneurysms at two centers from February 2022, to January 2024, where SMP plugs were used. Safety outcomes included inadvertent embolization and sac perforation during manipulation. Efficacy outcomes were volume and diameter changes, as well as endoleaks, and reinterventions using TeraRecon radiologic software. RESULTS: There were 29 patients who underwent EVAR with SMP plugs during the study period who had 1-year imaging data available for review. The mean age was 77 years (standard deviation, 8.8 years), and 72% were men. Preoperative median total aneurysm volume was 98 mL (interquartile range [IQR], 80-157 mL), and median preoperative blood lumen volume was 70 mL (IQR, 58-96.7 mL), with 62% patent inferior mesenteric arteries and one accessory renal artery. The median number of plugs used per patient was 90 (IQR, 51-130). The most frequently used grafts were the Gore Excluder (n = 23) and Cook Zenith (n = 6), with four iliac branch devices, five hypogastric coil covers, and Aptus Endoanchors in one patient. At 1 year, there were no patients with evidence of endoleak, no reinterventions, no adverse safety events during the procedure, and no perioperative deaths. The median percentage change in aneurysm volume at 1 year was 17% regression (IQR, 7%-33%), and the median change in aneurysm diameter was 6 mm regression (IQR, -10 mm to -1 mm). By diameter at 1 year postoperatively, 55% of patients (n = 16) demonstrated regression, 45% of patients (n = 13) demonstrated stability, and there were no patients with expansion. In volume analysis, 67% of those patients who regressed showed >10% regression in aneurysm volume. CONCLUSIONS: Preemptive aneurysm sac embolization at the time of EVAR is a safe and effective method of inducing sac thrombosis. At 1-year follow-up, patients have demonstrated high rates of sac regression, no endoleaks, and no need for reintervention. The SMP plugs hold promise over other coil or liquid embolic methods as they are biodegradable, and do not produce significant artifact on computed tomography scan. Longer-term data are needed to confirm these outcomes; however, 1-year postoperative outcomes continue to demonstrate promise.
引用
- Sansosti AA, O'Donnell TFX, Skripochnik E, et al. Preemptive aneurysm sac embolization for infrarenal endovascular aneurysm repair. J Vasc Surg. 2025. PMID: 40780665. doi:10.1016/j.jvs.2025.07.052
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。