本文报道一例55岁Marfan综合征女性,既往多次心血管手术及FEVAR(移植物对移植物),因V型胸腹主动脉瘤症状性增大并迟发IIIB/IIIC型内漏(支架脱节、断裂及织物撕裂累及肾/内脏动脉桥接支架),行紧急球囊扩张支架再衬附,术后症状完全缓解、无脊髓缺血。文献复习8项研究显示FEVAR后IIIB/IIIC型内漏发生率4%-5.9%,可能被低估,建议增加支架突出和放大率以预防再脱节。

要点

  • Marfan综合征FEVAR术后迟发IIIB/IIIC型内漏可表现为支架脱节、断裂或织物撕裂,需紧急再衬附。
  • 紧急再衬附采用球囊扩张支架并增加支架突出和放大率,可成功隔绝动脉瘤并维持靶血管通畅。
  • 文献报道FEVAR后IIIB/IIIC型内漏发生率4%-5.9%,在结缔组织病患者中可能被低估。

核心结论

  • 血管内治疗为Marfan综合征患者提供可行选择,尤其在高手术风险的再手术病例中。
  • FEVAR后IIIB/IIIC型内漏在Marfan综合征中虽少见(4%-5.9%)但可能被低估,需终身监测。

研究设计与样本

  • 病例报告:55岁Marfan综合征女性,既往多次心血管手术包括FEVAR(移植物对移植物),因V型胸腹主动脉瘤症状性胸痛就诊。
  • 文献复习按PRISMA指南检索「MFS」「IIIB/IIIC型内漏」「开窗支架」相关报告,43篇报告中8项研究符合纳入标准。

主要发现

  • CT血管造影显示IIIB/IIIC型内漏,源于支架脱节、支架断裂及织物撕裂,累及肾和内脏动脉桥接支架。
  • 紧急血管内再衬附使用球囊扩张支架,增加支架突出和放大率,术后病程平稳,症状完全缓解,无脊髓缺血证据。
  • 随访影像确认动脉瘤完全隔绝,靶血管通畅性维持。
  • 文献复习显示FEVAR后IIIB/IIIC型内漏发生率为4%-5.9%,在Marfan综合征患者中可能被低估。

关键数值与推荐

  • 文献复习纳入8项研究,FEVAR后IIIB/IIIC型内漏发生率报告为4%-5.9%。
  • 再手术病例中可考虑增加支架突出和更大放大率等辅助策略以预防进一步脱节。

临床怎么用

  • 对Marfan综合征FEVAR术后患者应终身在专科中心进行主动脉监测和延长仔细随访。
  • 再手术病例中采用增加支架突出和放大率的球囊扩张支架再衬附可作为紧急处理选择。

局限性

  • 单例病例报告,结论推广受限。
  • 文献复习仅纳入8项研究,IIIB/IIIC型内漏发生率可能被低估。
  • 桥接支架与靶血管动脉壁的长期相互作用研究不足。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Although open repair remains the standard of care for managing connective tissue disorders (CTDs), endovascular repair has emerged as an alternative, especially in patients with prior aortic surgery, using a "graft-to-graft" approach. Notwithstanding, long-term interaction between bridging stent-grafts and arterial wall of target vessels (TVs) remains under-investigated. We present a rare case of late-onset type IIIB/IIIC endoleaks in a symptomatic type V thoracoabdominal aortic aneurysm (TAAA) following fenestrated endovascular aneurysm repair (FEVAR) in a patient with Marfan syndrome (MFS), and a literature review. METHODS: A 55-year-old woman with MFS and a history of multiple cardiovascular surgeries, including previous FEVAR using a graft-to-graft approach, presented with chest pain secondary to a large type V TAAA. Computed tomography angiography revealed type IIIB/IIIC endoleaks due to stent disconnection, stent fracture, and fabric tears involving renal and visceral arteries' bridging stents. An urgent endovascular relining was performed with balloon-expandable stent-grafts, achieving enhanced stent protrusion and increased oversizing. The postoperative course was uneventful, with complete resolution of symptoms and no evidence of spinal cord ischemia. Follow-up imaging confirmed complete aneurysm exclusion and maintained patency of TVs. Additionally, a comprehensive literature review was conducted in accordance with PRISMA guidelines, using the search term "MFS," "type IIIB/IIIC endoleak," and "Fenestrated stent-graft" to investigate the rate of incident type III endoleak. Out of 43 identified reports, 8 studies met the inclusion criteria. RESULTS: Although infrequent (4%-5.9%), type IIIB/IIIC endoleaks after FEVAR in MFS patients may be underreported. These endoleaks may result from under-investigated interactions between bridging stents and TVs, especially due to the inherent fragility of the aortic wall in CTDs. In redo cases, adjunctive strategies, such as increased stent protrusion and greater oversizing, may be necessary to prevent further disconnections. CONCLUSIONS: Endovascular therapy provides a viable option for managing MFS patients, particularly in challenging redo cases with prohibitive surgical risks. Lifelong aortic surveillance in specialized centers and extended and careful follow-up is essential to assess the risks and the true incidence of high-flow endoleaks, as well as the overall safety and durability of these interventions, especially given the progressive nature of CTDs.Clinical ImpactThis study demonstrated the feasibility, safety, and time- and cost-effectiveness of single-disc vascular plug embolization for directional branches during urgent or emergent branched endovascular aortic aneurysm repair using off-the-shelf devices, even without elongation with balloon-expandable stent-grafts. This approach is particularly relevant in urgent scenarios, where minimizing procedural time is critical for optimizing patient outcomes, as well as in resource-limited settings, where efficient allocation of healthcare resources is essential.