文献速递主动脉疾病

EVAR中稀释对比剂DSA方案的初步经验

Preliminary Experience of Protocol for Digital Subtraction Angiography Using Diluted Contrast Medium during Endovascular Aneurysm Repair.
PubMed 文献 · Ann Vasc Surg · 2025-07-09

本研究通过离体实验制定低浓度对比剂DSA(LC-DSA)方案,前瞻性分析17例EVAR患者,与11例历史对照组比较。LC-DSA组对比剂用量显著降低(15.8 mL vs. 64.6 mL,P < 0.001),临床结局无显著差异,但图像质量较差且辐射剂量显著增高。

要点

  • LC-DSA方案可显著减少EVAR术中对比剂用量。
  • 技术成功率和围术期并发症与常规对比剂组无显著差异。
  • LC-DSA组图像质量下降且辐射剂量显著增加,需进一步改进。

核心结论

  • EVAR中LC-DSA方案可减少对比剂用量而不影响临床结局,但图像质量较差且辐射暴露显著增加。

研究设计与样本

  • 通过离体实验制定LC-DSA方案,前瞻性分析17例EVAR患者,历史对照组11例使用常规对比剂。

主要发现

  • LC-DSA组对比剂用量显著低于对照组(15.8 mL vs. 64.6 mL,P < 0.001)。
  • 两组技术成功率(P = 0.44)和围术期并发症(P = 0.35)无显著差异。
  • LC-DSA组对比噪声比显著低于对照组(35.2 vs. 53.8,P = 0.01)。
  • LC-DSA组辐射剂量显著高于对照组(1290.0 mGy vs. 393.7 mGy,P < 0.001)。

临床怎么用

  • 在需减少对比剂用量的EVAR患者中可考虑LC-DSA方案,但需权衡图像质量下降和辐射剂量增加的风险。

局限性

  • 样本量小且对照组为历史队列,非随机设计。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aimed to evaluate the efficacy of digital subtraction angiography (DSA) using low-concentration contrast medium (LC-DSA) during endovascular aneurysm repair (EVAR). METHODS: An LC-DSA protocol for EVAR using the Infinix Celeve-i angiography system (Canon Medical Systems Corporation, Tochigi, Japan) was developed through an ex vivo experiment. Seventeen patients undergoing EVAR using the LC-DSA protocol between October 2018 and November 2019 were prospectively analyzed. A historical cohort that underwent EVAR using a normal contrast medium between November 2017 and May 2018 was included as the control group (n = 11). RESULTS: Contrast medium use was significantly lower in the LC-DSA group (15.8 mL vs. 64.6 mL, P < 0.001). There were no significant differences between the groups in clinical outcomes, including technical success (P = 0.44) and perioperative complications (P = 0.35). However, the quality of the DSA image was significantly inferior in the LC-DSA group (contrast noise ratio; 35.2 vs. 53.8, P = 0.01), and the radiation dose was significantly higher in the LC-DSA group (1290.0 mGy vs. 393.7 mGy, P < 0.001). CONCLUSION: The LC-DSA protocol for EVAR can reduce the amount of contrast medium used without affecting the clinical outcomes. However, this is associated with inferior image quality and a significant increase in radiation exposure, warranting further improvements.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Yu A, Fujimura N, Hosokawa K, et al. Preliminary Experience of Protocol for Digital Subtraction Angiography Using Diluted Contrast Medium during Endovascular Aneurysm Repair. Ann Vasc Surg. 2025. PMID: 40645570. doi:10.1016/j.avsg.2025.06.038

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。