四维CT诊断EVAR后IIIb型内漏致瘤囊扩大并再干预一例
本文报告一例75岁男性腹主动脉瘤EVAR术后13年、瘤囊逐渐扩大至55 mm的病例。传统增强CT发现内漏但无法分型,四维CT明确诊断为IIIb型内漏,遂行relining EVAR再干预,术后增强CT证实内漏消失。结论认为4D-CT可能有助于识别EVAR后内漏类型。
要点
- EVAR术后远期瘤囊扩大需警惕内漏,传统CT可能无法区分II型与III型。
- 四维CT可明确诊断IIIb型内漏,为再干预决策提供依据。
- relining EVAR后再复查增强CT证实内漏消失。
核心结论
- EVAR后IIIb型内漏常难以用传统模态诊断,4D-CT可能有助于识别内漏类型。
研究设计与样本
- 个案报告:1例75岁男性,13年前因腹主动脉瘤行EVAR,术后10年无主动脉事件,其后瘤囊逐渐扩大至直径55 mm。
主要发现
- 传统增强CT显示内漏但无法确定类型(II型或III型)。
- 四维CT作出IIIb型内漏的明确诊断。
- 行relining EVAR再干预,术后增强CT证实内漏消失。
临床怎么用
- EVAR术后随访中瘤囊扩大且传统CT无法分型时,可考虑使用4D-CT识别内漏类型。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: We describe a case in which 4-dimensional computed tomography (4D-CT) was used to detect a type IIIb endoleak after endovascular aneurysm repair (EVAR). CASE REPORT: The patient was a 75-year-old man who underwent EVAR for abdominal aortic aneurysm at our institute 13 years before presentation. The patient had been aortic event-free for 10 years postoperation. However, the sac gradually enlarged after 10 years and reached 55 mm in diameter. Traditional contrast-enhanced CT showed an endoleak but could not be used in type determination (type II or III). Four-dimensional-CT enabled us to make a definitive diagnosis of a type IIIb endoleak; therefore, relining EVAR was performed as a reintervention. Postoperative contrast-enhanced computed tomography confirmed disappearance of the endoleak. CONCLUSION: Type IIIb endoleaks following EVAR are often difficult to diagnose using traditional modalities. Thus, 4D-CT may be useful in identifying endoleak types.Clinical ImpactThis case report highlights the effectiveness of four-dimensional computed tomography (4D-CT) in diagnosing type IIIb endoleaks after endovascular aneurysm repair (EVAR). Traditional imaging methods often fail to accurately identify this type of endoleak, which can lead to aneurysm rupture if untreated. The use of 4D-CT allowed for a definitive diagnosis and timely reintervention, thus improving patient outcomes. Incorporating 4D-CT into post-EVAR surveillance protocols may enhance the detection and management of type IIIb endoleaks, potentially reducing the risk of complications and improving long-term patient prognosis.
引用
- Tomita S, Masada K, Yoshida K, et al. Endovascular Aneurysm Repair for a Sac Enlargement Caused by Type IIIb Endoleak Diagnosed Using Four-Dimensional Computed Tomography. J Endovasc Ther. 2025. PMID: 40576162. doi:10.1177/15266028251344806
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。