本文报道一例采用预装载左锁骨下动脉(LSA)开窗和缩径束带的医师改良血管内移植物(PMEG),在2区胸主动脉腔内修复(TEVAR)中实现开窗与LSA精准对齐的技术。术中将预装载导丝经股动脉引入、肱动脉引出建立贯通导丝,在缩径束带释放前于开窗和LSA内充盈12 mm球囊,随后释放束带确保对齐,LSA以球囊扩张覆膜支架置入。随访血管造影和CT血管造影显示技术成功。

要点

  • 预装载LSA开窗建立贯通导丝可辅助PMEG在2区TEVAR中的定向与对齐。
  • 缩径束带释放前于开窗和LSA内充盈12 mm球囊,有助于开窗与LSA精准对齐。
  • 随访血管造影和CT血管造影证实技术成功。

核心结论

  • 构建带缩径束带和预装载LSA开窗的PMEG以建立贯通导丝,可能有助于实现精准对齐,随着时间推移提高2区开窗TEVAR手术的一致性。

研究设计与样本

  • 技术报告,描述一例采用预装载LSA开窗和缩径束带的PMEG治疗起源于LSA水平的主动脉壁内血肿的TEVAR。

主要发现

  • 预装载导丝经股动脉入路引入并从肱动脉引出,PMEG经股总动脉引入,贯通导丝辅助移植物定向。
  • 在释放缩径束带前,于开窗和LSA内充盈12 mm球囊,随后在球囊充盈下释放缩径束带,确保开窗与LSA精准对齐。
  • LSA以球囊扩张覆膜支架置入,完成血管造影和随访CT血管造影显示技术成功。

关键数值与推荐

  • 使用Relay Plus覆膜支架行LSA开窗改造,并添加缩径束带和预装载开窗。
  • 在开窗和LSA内充盈12 mm球囊,随后释放缩径束带。
  • LSA以球囊扩张覆膜支架置入。

临床怎么用

  • 该技术可能通过预装载开窗建立贯通导丝联合缩径束带,辅助2区TEVAR中开窗与LSA的精准对齐。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This report describes the use of a physician-modified endovascular graft (PMEG) with a preloaded fenestration for the left subclavian artery (LSA) and diameter-reducing ties to facilitate alignment between the fenestration and LSA. TECHNIQUE: Thoracic endovascular aortic repair (TEVAR) was performed to treat an intramural aortic hematoma originating at the level of the LSA. A Relay Plus endograft was modified with a fenestration for the LSA. Diameter-reducing ties were added, and the fenestration was preloaded. The preloaded guidewire was introduced at the femoral access and externalized at the brachial artery. The PMEG was then introduced via the common femoral artery with the through-and-through guidewire assisting in the orientation of the endograft. Before releasing the diameter-reducing ties, a 12 mm balloon was inflated within the fenestration and LSA. The diameter-reducing ties were released while the balloon was inflated, ensuring precise alignment of the fenestration with the LSA. The LSA was stented using a balloon-expandable covered stent. Completion angiography and computerized tomography angiography at follow-up demonstrated technical success. CONCLUSION: Constructing a PMEG with diameter-reducing ties and a preloaded LSA fenestration to establish a through-and-through wire could facilitate precise alignment, improving procedural consistency over time of fenestrated TEVAR in zone 2.Clinical ImpactEndovascular methods for left subclavian artery (LSA) preservation during thoracic endovascular aortic repair (TEVAR) in zone 2 are gaining in popularity. One promising endovascular treatment option is construction of a fenestrated physician-modified endovascular graft (PMEG). Achieving precise alignment between the fenestration and LSA can be challenging. The current report demonstrates a technique to preload the LSA fenestration to establish a through-and-through wire, which, in combination with diameter reducing ties, can potentially aid in achieving consistent results by obtaining a perfect alignment in a quick manner.