超低剂量CT联合深度学习重建用于EVAR术后动脉瘤直径测量的可行性

Feasibility of Ultralow-Dose CT With Deep-Learning Reconstruction for Aneurysm Diameter Measurement in Post-EVAR Follow-Up: A Prospective Comparative Study With Conventional CT.
PubMed 文献 · J Endovasc Ther · 2025-06-16

前瞻性单中心研究纳入44例EVAR术后患者,先后行标准剂量CT(SD-CT)和超低剂量CT(ULD-CT)监测,ULD-CT采用深度学习重建(DLR),SD-CT采用迭代重建。ULD-CT的CT剂量指数和剂量长度乘积均显著低于SD-CT,动脉瘤囊短径测量差异为-0.37 mm(95%CI -0.6至-0.12),图像质量评分较低,但测量精度满足术后监测需求。

要点

  • ULD-CT联合DLR的辐射剂量显著低于SD-CT(CTDIvol 1.0 vs 6.9 mGy,DLP 71.4 vs 500.9 mGy·cm,p<0.001)。
  • 动脉瘤囊短径测量:ULD-CT较SD-CT平均差-0.37 mm(95%CI -0.6至-0.12 mm)。
  • ULD-CT图像质量评分低于SD-CT(3.3 vs 4.5,p<0.001),但测量精度满足EVAR术后监测。

核心结论

  • ULD-CT联合DLR测量动脉瘤囊直径对于EVAR术后监测足够准确,且较SD-CT大幅降低辐射。

研究设计与样本

  • 前瞻性单中心研究,44例EVAR术后患者先后接受SD-CT和ULD-CT监测。
  • ULD-CT图像采用深度学习重建(DLR),SD-CT图像采用迭代重建。
  • 三名放射科医生在不知患者信息和CT条件下独立测量动脉瘤囊直径并评估整体图像质量。
  • 采用Bland-Altman分析和线性混合效应模型评估和比较SD-CT与ULD-CT的测量准确性。

主要发现

  • ULD-CT的CT剂量指数体积为1.0±0.3 mGy,剂量长度乘积为71.4±26.5 mGy·cm;SD-CT分别为6.9±0.9 mGy和500.9±96.0 mGy·cm(p<0.001)。
  • 三名观察者测量的动脉瘤囊平均短径:SD-CT为46.7±10.8 mm,ULD-CT为46.3±10.8 mm。
  • ULD-CT与SD-CT的动脉瘤囊短径平均差异为-0.37 mm(95%CI -0.6至-0.12 mm)。
  • 观察者1、2、3的ULD-CT与SD-CT测量观察者内一致性界限(LOA)分别为-3.5至2.6、-2.8至1.9、-2.9至2.3。
  • 观察者间一致性成对LOA(如观察者1与2在SD-CT测量的差异)大多在预设可接受范围内。

临床怎么用

  • ULD-CT联合DLR可用于EVAR术后动脉瘤囊直径监测,测量精度足够且辐射剂量显著低于SD-CT。
  • DLR为软件算法,无需专用硬件,有望整合到标准CT系统中,使ULD-CT在各类机构广泛可及。
  • 该技术有望大幅降低EVAR术后CT成像的辐射暴露,促进其成为EVAR术后监测的标准模式。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: We conducted a prospective study to evaluate the usefulness of ultralow-dose computed tomography (ULD-CT) with deep-learning reconstruction (DLR) compared with conventional standard-dose CT (SD-CT) for post-endovascular aneurysm repair (EVAR) surveillance. MATERIALS AND METHODS: We prospectively performed post-EVAR surveillance using ULD-CT at a single center in 44 patients after they had received SD-CT. The ULD-CT images underwent DLR, whereas the SD-CT images underwent iterative reconstruction. Three radiologists blinded to the patient information and CT conditions independently measured the aneurysmal sac diameter and evaluated the overall image quality. Bland-Altman analysis and a linear mixed-effects model were used to assess and compare the measurement accuracy between SD-CT and ULD-CT. RESULTS: The mean CT dose index volume and dose-length product were significantly lower for ULD-CT (1.0 ± 0.3 mGy and 71.4 ± 26.5 mGy•cm) than that for SD-CT (6.9 ± 0.9 mGy and 500.9 ± 96.0 mGy•cm; p<0.001). The mean short diameters of the aneurysmal sac measured by the 3 observers were 46.7 ± 10.8 mm on SD-CT and 46.3 ± 10.8 mm on ULD-CT. The mean difference in the short diameter of the aneurysmal sac between ULD-CT and SD-CT was -0.37 mm (95% confidence interval, -0.6 to -0.12 mm). The intraobserver limits of agreement (LOA) for measurements by ULD-CT and SD-CT were -3.5 to 2.6, -2.8 to 1.9, and -2.9 to 2.3 for Observers 1, 2, and 3, respectively. The pairwise LOAs for assessing interobserver agreement, such as for the differences between Observers 1 and 2 measurements in SD-CT, were mostly within the predetermined acceptable range. The mean image-quality score was lower for ULD-CT (3.3 ± 0.6) than that for SD-CT (4.5 ± 0.5; p<0.001). CONCLUSION: Aneurysmal sac diameter measurements by ULD-CT with DLR were sufficiently accurate for post-EVAR surveillance, with substantial radiation reduction versus SD-CT.Clinical ImpactDeep-learning reconstruction (DLR) is implemented as a software-based algorithm rather than requiring dedicated hardware. As such, it is expected to be integrated into standard computed tomography (CT) systems in the near future. The ultralow-dose CT (ULD-CT) with DLR evaluated in this study has the potential to become widely accessible across various institutions. This advancement could substantially reduce radiation exposure in post-endovascular aneurysm repair (EVAR) CT imaging, thereby facilitating its adoption as a standard modality for post-EVAR surveillance.