分支支架腔内修复腹主动脉瘤并灌注Adamkiewicz动脉
本文报道一例81岁男性肾旁腹主动脉瘤(64 mm)患者,影像发现直径4.5 mm的Adamkiewicz动脉,采用定制分支支架经右股动脉和左腋动脉入路行腔内修复,在栓塞肠系膜下动脉后植入支架,保持肾动脉、Adamkiewicz动脉和内脏血管通畅。作者认为,对于累及粗大Adamkiewicz动脉的广泛主动脉瘤,分支腔内修复时考虑此类个性化方案。
要点
- 定制分支支架可保留Adamkiewicz动脉灌注,同时隔绝动脉瘤。
- 长段主动脉隔绝与脊髓缺血风险相关,保留该动脉或有助于降低截瘫风险。
- 该个案显示个性化支架适配解剖的可行性。
核心结论
- 作者认为,对于累及粗大Adamkiewicz动脉的广泛主动脉瘤行分支腔内修复时,应考虑保留该动脉灌注的个性化支架方案。
研究设计与样本
- 个案报道:81岁男性,肾旁腹主动脉瘤直径64 mm。
主要发现
- 影像显示Adamkiewicz动脉直径4.5 mm。
- 经右股动脉和左腋动脉入路,栓塞肠系膜下动脉后植入定制分支支架,保持肾动脉、Adamkiewicz动脉和内脏血管通畅。
- 动脉瘤被隔绝于循环之外,同时维持脊髓灌注。
临床怎么用
- 本案例提示,定制分支支架可适配患者解剖,在隔绝动脉瘤的同时保留Adamkiewicz动脉灌注。
- 作者观点:广泛主动脉瘤累及粗大Adamkiewicz动脉行分支腔内修复时,可考虑此类方案。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Exclusion of long aortic segments in the treatment of endovascular thoracoabdominal aortic aneurysms is associated with a higher risk of spinal cord ischemia. We present the successful implantation of a branch stent graft with perfusion of the great Adamkiewicz artery to diminish risk of paraplegia. CASE DESCRIPTION: An 81-year-old man was diagnosed with a perirenal aneurysm of the abdominal aorta (64 mm). Imaging examination revealed an Adamkiewicz artery with a diameter of 4.5 mm. Endovascular treatment was conducted using a customized branched stent graft with an additional branch to the Adamkiewicz artery, with access via the right femoral artery and the left axillary artery. After embolization of the inferior mesenteric artery, a stent graft was implanted, maintaining patency of the renal arteries, Adamkiewicz artery and visceral vessels. DISCUSSION: This case demonstrates the effectiveness of personalized stent grafts adapted to the patient's anatomy. The stent graft used, with a branch to the Adamkiewicz artery, allowed the aneurysm to be excluded from the circulation while maintaining spinal cord perfusion. CONCLUSION: In our opinion, such a solution should be considered in cases of extensive aortic aneurysms involving the large Adamkiewicz artery treated with branched endovascular aneurysm repair.Clinical ImpactPresented case illustrates the potential of customized stent-grafts, which can be adapted to the patient's anatomy. Spinal cord ischemia remains a significant complication of endovascular repair of aortic aneurysms. A prosthesis providing adequate perfusion of the Adamkiewicz artery may prove an additional method of preventing paraplegia. There is a paucity of literature on the repair of aortic aneurysms with the implantation of branched stent grafts with a branch into the Adamkiewicz artery, which serves to highlight the innovation of our treatment. The presented case offers new insights into the prevention of paraplegia with branched endovascular aneurysm repair procedures.
引用
- Wołoszyn A, Kasprzak P, Toroń M, et al. Endovascular Treatment of Abdominal Aortic Aneurysm Using a Branched Stent-Graft With Perfusion of the Adamkiewicz Artery. J Endovasc Ther. 2025. PMID: 40464252. doi:10.1177/15266028251344785
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。