钝性创伤性主动脉损伤TEVAR的手术环境与结局
基于PROOVIT注册库2012至2021年14家美国创伤中心199例因钝性主动脉损伤行TEVAR的病例,比较标准手术室便携C臂与固定成像系统(杂交手术室或介入放射室)下的操作特征与并发症。C臂病例手术时间更长且并发症率更高,全部3例卒中均发生于C臂组。
要点
- C臂组TEVAR并发症预测因素包括使用C臂(P = .03)及TEVAR时间<6小时(P = .04)。
- 全部3例卒中均发生于C臂组(P = .04)。
- 杂交手术室病例ISS中位数38(IQR 14),高于C臂33(IQR 15)和IR 29(IQR 25)(P = .02)。
核心结论
- 尽管技术进步,BTAI的TEVAR仍常在标准手术室使用C臂成像而非固定成像系统进行;C臂手术耗时更长、并发症率更高(包括卒中);在杂交手术室使用固定成像系统进行TEVAR最安全。
研究设计与样本
- PROOVIT(PROspective Observational Vascular Injury Treatment)注册库研究,覆盖美国14家创伤中心。
- 查询2012至2021年因BTAI行TEVAR的病例,分为标准手术室便携C臂组(C-Arm)、杂交手术室组(Hybrid)和介入放射室组(IR),采用单变量分析比较。
主要发现
- 共199例TEVAR:C臂82例、杂交75例、IR 42例;手术环境无明确时间趋势。
- 杂交组ISS中位数38(IQR 14),高于C臂33(IQR 15)和IR 29(IQR 25)(P = .02)。
- AIS头部评分>3比例:杂交44% vs C臂28% vs IR 24%(P = .06)。
- 入 arrival后>6小时手术比例:杂交78% vs C臂48% vs IR 41%(P < .001);手术时长>3小时比例:C臂34% vs 杂交12% vs IR 15%(P = .002)。
- 使用C臂(P = .03)和TEVAR时间<6小时(P = .04)为并发症预测因素;全部3例卒中均发生于C臂组(P = .04)。
临床怎么用
- 原文结论为BTAI的TEVAR在杂交手术室使用固定成像系统进行最安全。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Thoracic endovascular aortic repair (TEVAR) has become the mainstay of treatment for blunt thoracic aortic injuries (BTAI) over open repair. Since the arrival of TEVAR, hybrid operating rooms have emerged as highly specialized environments equipped to streamline endovascular and open cases. Procedure characteristics and outcomes may vary when TEVAR is performed in the setting of a standard operating room with a portable C-Arm vs in a hybrid operating room or interventional radiology (IR) suite with a fixed imaging system. The purpose of this study was to compare clinical characteristics and outcomes of TEVAR for BTAI across these settings. We hypothesize that cases performed with a C-Arm would lead to higher rates of complications. METHODS: The PROOVIT registry (PROspective Observational Vascular Injury Treatment) captures trauma-specific outcomes related to vascular injury across 14 trauma centers in the United States. The registry was queried for BTAI undergoing TEVAR from 2012 to 2021. Cases were categorized as having been performed in a standard operating room with portable C-Arm imaging (C-Arm), or in a fixed imaging suite (hybrid room [Hybrid] or IR). Procedural characteristics and complications (arterial access, reintervention, stroke) were collected and compared using univariate analyses. RESULTS: PROOVIT contained 199 TEVAR for BTAI: 82 C-Arm, 75 Hybrid, and 42 IR cases. There was no clear temporal trend in the setting TEVAR was performed. Demographics and mechanism of injury were similar between groups; Hybrid room procedures had higher median Injury Severity Score (ISS) (38; interquartile range [IQR], 14) than C-Arm (33; IQR, 15) and IR (29; IQR, 25; P = .02) and a higher proportion of cases with an Abbreviated Injury Scale head score of >3 (44% vs 28% C-Arm vs 24% IR; P = .06). Hybrid cases were most often delayed >6 hours from arrival (78% vs 48% vs 41%; P < .001), but C-Arm cases most frequently lasted >3 hours (34% vs 12% Hybrid vs 15% IR; P = .002). Use of C-Arm (P = .03) and time to TEVAR of <6 hours (P = .04) were predictors of complications. All strokes (n = 3) occurred in C-Arm cases (P = .04). CONCLUSIONS: Despite technological advances, TEVAR for BTAI is still performed frequently in a standard operating room with C-Arm imaging, rather than with a fixed imaging system in a hybrid operating room or IR suite. C-Arm procedures take longer and have higher complication rates, including stroke. TEVAR for BTAI is conducted most safely using a fixed imaging system in a hybrid operating room setting.
引用
- Cabot JH, Zubkov M, Knowlton LM, et al. Hospital setting of endovascular repair influences procedural outcomes in blunt traumatic aortic injury. J Vasc Surg. 2025. PMID: 40464724. doi:10.1016/j.jvs.2025.04.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。