文献速递主动脉疾病

E-nside即用型内分支胸腹主动脉覆膜支架的学习曲线演变

Evolution of practice patterns and learning curve of aortic repair using the E-nside off-the-shelf inner branch thoracoabdominal endograft.
PubMed 文献 · J Vasc Surg · 2025-06-04

基于意大利多中心前瞻性注册研究(2020-2024),215例使用E-nside覆膜支架行分支腔内主动脉修复的患者按各中心中位手术日期分为早期(108例)和晚期(107例)队列。

要点

  • 2年支架不稳定、靶血管不稳定及靶血管一期通畅率在两组间无显著差异。

核心结论

  • 随着E-nside覆膜支架使用经验增加,全经股动脉入路及球囊扩张和加强桥接支架使用更频繁,术中并发症显著减少。
  • 大多数中心从早期即达到稳定的死亡率、主要不良事件、手术指标和中远期结果。

研究设计与样本

  • 医生发起的全国多中心前瞻性注册研究(INBREED),纳入2020-2024年使用E-nside覆膜支架治疗的患者。
  • 共215例患者,按各中心手术日期中位数分为早期队列108例(393根靶血管)和晚期队列107例(395根靶血管)。

临床怎么用

  • 使用E-nside覆膜支架时,随着经验积累可更多采用全经股动脉入路及球囊扩张和加强桥接支架。
  • 学习曲线早期即可获得稳定的死亡率和主要不良事件,术中并发症在后期减少。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To report the impact of the learning curve on the outcomes of branched endovascular aortic repair using an off-the-shelf preloaded inner branch device (E-nside). METHODS: Data from a physician-initiated national multicenter registry, including patients treated with E-nside endograft (INBREED [ItaliaN Branch Registry of E-nside EnDograft]) were collected prospectively (2020-2024). End points were early (30-day) technical success, mortality, major adverse events (MAEs), and 2-year freedom from endograft instability and target vessel instability. Patients were divided into early and late cohorts based on the median date of the procedure in each center. RESULTS: There were 215 patients treated with the E-nside, 108 (393 target vessels) in the early and 107 (395 target vessels) in the late cohort. Most patients had a degenerative aneurysm (early, 82%; late, 75%; P = .326) or a chronic dissection (early, 6%; late, 15%; P = .025). Aneurysm extent was thoracoabdominal in 53% of patients and complex abdominal in 47%; and 23% were ruptured or symptomatic and 26% had an aneurysm size of more than 70 mm, without differences between groups. A narrow paravisceral aortic lumen of less than 25 mm was more frequent in the late cohort (late, 30%; early, 18%; P = .037). From the early to the late groups, there was an increase in the use of a total transfemoral approach (late, 29% vs early, 18%; P = .042), balloon-expandable bridging stents (late, 82% vs early, 76%; P = .032), and reinforcement bridging stents (late, 26%; early, 11%; P < .001). Operating time (late, 267 ± 131 minutes; early, 244 ± 130 minutes; P = .230), iodinated contrast volume (late, 181 ± 81 mL; early, 210 ± 141 mL; P = 108; P = .302), and dose area product (late, 272 ± 110 Gycm2 early, 291 ± 118 Gycm2; P = .277) were similar in the two groups. Intraprocedural complications decreased in the later stage of the learning curve (late, 11%; early, 23%; P = .030), whereas overall 30-day mortality (late, 8%; early, 6%; P = .346), technical success (late, 99%; early, 98%; P = .286), and MAEs (late, 27%; early, 29%; P = .879) remained substantially stable. There were no differences in 2-year freedom from endograft instability (late, 100 ± 0%; early, 96 ± 5%; P = 1.00), freedom from target vessel instability (late, 98 ± 3%; early, 94 ± 2%; P = .090), and target vessel primary patency (late, 97 ± 2%; early, 97 ± 2%; P = .321). CONCLUSIONS: The increased experience with the E-nside endograft was associated with a more frequent use of a total transfemoral approach and use of balloon-expandable and reinforced bridging stents. From the early to the late stages, there was a significant decrease in intraoperative complications, although most centers were learning independent and achieved a consistent mortality, MAE, procedural metrics, and mid-term results from the start.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Squizzato F, Piazza M, Piffaretti G, et al. Evolution of practice patterns and learning curve of aortic repair using the E-nside off-the-shelf inner branch thoracoabdominal endograft. J Vasc Surg. 2025. PMID: 40480614. doi:10.1016/j.jvs.2025.05.036

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。