文献速递颈动脉与弓上血管

颈动脉斑块破裂与卒中相关生物力学力的系统综述

Systematic review of biomechanical forces associated with carotid plaque disruption and stroke.
PubMed 文献 · J Vasc Surg · 2025-05-14

该系统综述评估作用于颈动脉斑块的生物力学力及其与不良结局的关系。共纳入154项研究,主要测量壁面剪切应力(WSS)和斑块壁应力(PWS)。PWS>160 kPa识别不良事件的敏感性>80%、特异性>75%;WSS>50 dyn/cm²的敏感性100%、特异性67%;

要点

  • PWS>160 kPa识别不良事件敏感性>80%、特异性>75%。
  • WSS>50 dyn/cm²区分不良事件敏感性100%、特异性67%。

核心结论

  • 文献在样本量、研究设计、影像协议、图像处理方法、评估的力及不良结局方面存在异质性。
  • 尽管存在上述局限,PWS和WSS升高与不良斑块结局一致相关,并以中至高度敏感性和特异性预测不良结局。
  • 由于现有信息异质,这些关系需在更大规模前瞻性研究中确认。

研究设计与样本

  • 系统综述,检索PubMed、Embase和Web of Science。
  • 筛查5635篇文章,154篇符合纳入标准。
  • 纳入标准:报告人类颈动脉斑块、使用患者特异性几何、测量斑块处或内部力、报告颈动脉斑块相关不良结局。

主要发现

  • 力计算主要基于磁共振成像(58.4%)和超声检查(25.3%)的患者特异性动脉几何。
  • 量化方法包括计算流体动力学(31.8%)、有限元分析(10.4%)、流固耦合模型(27.3%)、在体测量(29.9%)和体外评估(0.6%)。
  • 最常测量的力为WSS(72.1%的研究)和PWS(45.5%的研究)。
  • 主PWS(15项研究)和WSS(21项研究)在不良结局患者中升高。
  • PWS>160 kPa识别不良事件的敏感性>80%、特异性>75%;WSS>50 dyn/cm²区分不良事件(斑块破裂、脑梗死、卒中或短暂性脑缺血发作)的敏感性100%、特异性67%。

关键数值与推荐

  • PWS>160 kPa:识别不良事件敏感性>80%、特异性>75%。
  • WSS>50 dyn/cm²:区分不良事件敏感性100%、特异性67%。

临床怎么用

  • PWS和WSS升高与颈动脉斑块不良结局相关,并以中至高度敏感性和特异性预测不良结局。
  • 这些关系需在更大规模前瞻性研究中确认。

局限性

  • 文献在样本量、研究设计、影像协议、图像处理方法、评估的力及不良结局测量方面存在异质性。
  • 现有信息异质,这些关系需在更大规模前瞻性研究中确认。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Carotid plaque disruption with release of atheroembolic debris and consequent brain infarction is the primary mechanism for brain injury in patients with carotid stenosis. Disease severity is quantified traditionally by the degree of stenosis, although it is not an accurate marker of stroke risk. It has been proposed that biomechanical forces acting on a carotid plaque may render it vulnerable to rupture by causing adverse remodeling of its morphology or by direct disruption. We conducted a systematic review to assess the forces acting on carotid plaques and their relationship to adverse plaque outcomes. METHODS: A literature search for studies reporting measurements of flow-related biomechanical forces acting on carotid atherosclerotic plaques was conducted using PubMed, Embase, and Web of Science. Studies were included if they reported on human carotid plaques, used patient-specific geometry, measured forces on or in the atherosclerotic lesions, and reported on carotid plaque-related adverse outcomes. RESULTS: Of 5635 articles screened, 154 met eligibility criteria. Forces were computed using patient-specific arterial geometry derived from multiple imaging modalities, mainly magnetic resonance imaging (58.4%) and ultrasound examination (25.3%). Methodologies used to quantify the forces included computational fluid dynamics (31.8%), finite element analysis (10.4%), fluid-structure interaction models (27.3%), in vivo measurements (29.9%), and in vitro assessments (0.6%). Wall shear stress (WSS) and plaque wall stress (PWS) were the most frequently measured forces, in 72.1% and 45.5% of studies, respectively. Principal PWS (n = 15 studies) and WSS (n = 21 studies) were elevated in patients with adverse outcomes. PWS levels of >160 kPa had a sensitivity of >80% and specificity of >75% in identifying patients with adverse events. Increasing PWS was associated with subsequent ischemic cerebrovascular events (HR=hazard ratio, 12.98 per 1 kPa increase; P = .02). WSS levels of >50 dyn/cm2 had a sensitivity of 100% and specificity of 67% in differentiating patients with adverse events (plaque rupture, cerebral infarction, stroke, or transient ischemic attack) compared with those without. CONCLUSIONS: There is heterogeneity in sample size, study design, imaging protocols, image processing methodology, forces assessed, and adverse carotid plaque-related outcomes measured in the literature. Despite these limitations, increasing PWS and WSS were associated with adverse plaque outcomes consistently and predicted adverse outcomes with moderate to high degrees of sensitivity and specificity. Because the information available is heterogenous, these relationships need to be confirmed in larger prospective studies.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Jreij G, Canton G, Hippe DS, et al. Systematic review of biomechanical forces associated with carotid plaque disruption and stroke. J Vasc Surg. 2025. PMID: 40378930. doi:10.1016/j.jvs.2025.05.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。