文献速递主动脉疾病颈动脉与弓上血管

三支架构主动脉弓腔内修复术后左颈总动脉内分支方向的超声比较分析

Duplex ultrasound-based comparative analysis of inner branch orientation for the left common carotid artery following triple-branch arch endovascular repair.
PubMed 文献 · J Vasc Surg · 2025-05-05

本研究基于单中心前瞻性维护数据库,纳入39例接受三支架构主动脉弓腔内修复术的患者,比较左颈总动脉内分支顺行(18例)与逆行(21例)方向对术后颈动脉双功能超声灌注指标的影响。结果显示两种方向下双侧颈动脉灌注指标相似,逆行组手术时间更短且全经皮入路比例更高,30天卒中率5%(2例,均为顺行组),无死亡。

要点

  • 左颈总动脉内分支顺行与逆行方向术后颈动脉双功能超声灌注指标无显著差异。
  • 逆行组中位手术时间160分钟,顺行组218分钟。
  • 逆行组全经皮入路比例71%,顺行组17%。

核心结论

  • 在三支架构主动脉弓腔内修复术中,左颈总动脉内分支方向对双侧颈动脉双功能超声灌注指标无显著差异。
  • 左颈总动脉内分支逆行方向手术时间更短、全经皮入路比例更高,且未增加卒中或再干预发生率。
  • 这项回顾性研究进一步支持在有利解剖条件下将左颈总动脉内分支从顺行改为逆行方向。

研究设计与样本

  • 单中心回顾性研究,使用前瞻性维护的电子数据库,纳入2020年5月至2025年2月接受三支架构(Cook Medical)主动脉弓腔内修复术的患者。
  • 纳入标准为植入三支架构装置,头臂干为顺行内分支,左颈总动脉为顺行或逆行内分支,左锁骨下动脉为逆行分支。
  • 排除标准为无随访及术后双功能超声检查。
  • 共74例接受三支架构主动脉弓腔内修复术,其中39例符合纳入标准,左颈总动脉内分支顺行18例(46%)、逆行21例(54%)。

主要发现

  • 大多数患者为男性(74%),中位年龄72岁,高血压发生率90%,血脂异常59%。
  • 修复指征为退行性(51%)或慢性夹层后(49%)主动脉弓动脉瘤。
  • 逆行组全经皮入路比例71%,顺行组17%;左颈总动脉逆行分支中位手术时间160分钟,顺行组218分钟。
  • 30天卒中率5%(n=2,均为顺行组),无死亡。
  • 术后双功能超声显示实验侧左颈总动脉与对照侧右颈总动脉灌注指标相似,与左颈总动脉内分支方向无关;逆行组中右颈总动脉和左颈总动脉均以单相波(62%)和三相波(31%)为主,中位收缩期峰值流速64至68 cm/s、舒张末期流速17至21 cm/s、加速时间56至65 ms。

临床怎么用

  • 作者认为,在有利解剖条件下,左颈总动脉内分支逆行方向可缩短手术时间、提高全经皮入路比例,且未增加卒中或再干预。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The purpose of this study was to evaluate left common carotid artery (LCCA) perfusion using duplex ultrasound (DUS) examination after endovascular repair of the aortic arch (endoarch) with a triple-branch arch device, featuring either an anterograde or retrograde inner branch configuration for the LCCA. METHODS: Patients who underwent branched endoarch repair from May 2020 to February 2025 were identified using a prospectively maintained electronic database at a single tertiary care hospital. Inclusion criteria included implantation of the triple-branch arch device (Cook Medical) with an anterograde inner branch for the brachiocephalic trunk, an anterograde or retrograde inner branch for the LCCA, and a retrograde branch for the left subclavian artery. Exclusion criteria included no follow-up and postoperative DUS examination. Patient demographics, comorbidities, indication for the procedure, procedural details, and outcomes were recorded. The cohort was dichotomized based on LCCA branch orientation. The primary outcomes were to define postoperative DUS-based perfusion metrics of the bilateral carotid arteries and to compare them based on the orientation of the LCCA branch. The right CCA (RCCA) served as a control, because it featured only an anterograde branch for the brachiocephalic trunk. The secondary outcomes were to compare inner branch primary patency, stroke-related outcomes, reintervention, and mortality. RESULTS: A total of 74 patients underwent endoarch repair with the triple-branch arch device during the study period, of whom 39 met the study inclusion criteria, with 18 (46%) anterograde and 21 (54%) retrograde inner branches of the LCCA. Most patients were male (74%) with a median age of 72 years. There was a high incidence of hypertension (90%) and dyslipidemia (59%). The indication for repair was a degenerative (51%) or chronic postdissection (49%) aortic arch aneurysm. A totally percutaneous approach for procedural access occurred in 71% of the retrograde group (vs 17% anterograde). There was a decreased median operating time for LCCA retrograde branch of 160 minutes (vs 218 minutes anterograde). Thirty-day stroke was 5% (n = 2, both anterograde), with no mortality. Postoperative DUS examination demonstrated similar perfusion metrics between the experimental LCCA and the control RCCA, regardless of the orientation of the LCCA inner branch. In the retrograde group, both the RCCA and LCCA featured predominantly monophasic (62%) and triphasic (31%) waveforms; the median peak systolic velocity, end-diastolic velocity, and acceleration time were 64 to 68 cm/s, 17 to 21 cm/s, and 56 to 65 ms, respectively. Midterm outcomes (median follow-up, 11 months) were notable for one death, without events of stroke or target vessel-related reinterventions. CONCLUSIONS: In endoarch repair with the triple-branch device, inner branch orientation yields no significant difference in DUS-based perfusion metrics of both carotid arteries. In the retrograde orientation of the LCCA inner branch, there was decreased operative time with increased rates of a totally percutaneous approach, without an increased incidence of stroke or reintervention. This retrospective study further supports the device modification from the anterograde to retrograde orientation of the LCCA inner branch in favorable anatomies.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Aru RG, Bendavid J, Lame C, et al. Duplex ultrasound-based comparative analysis of inner branch orientation for the left common carotid artery following triple-branch arch endovascular repair. J Vasc Surg. 2025. PMID: 40334874. doi:10.1016/j.jvs.2025.04.062

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。