PubMed 文献 · J Vasc Surg · 2025-05-28

本研究回顾性分析单中心263例择期经皮腔内动脉瘤修复术(pEVAR)患者共511个股总动脉穿刺点,比较MANTA与ProGlide血管闭合器的临床结局。MANTA组技术失败率8.3%低于ProGlide组15.6%(P<.001),封堵不当发生率5.8%低于13.9%(P=.002),但出血率与转开放手术率两组无显著差异。作者认为两者均为安全选择,ProGlide首次成功率较低但可通过追加器械解决,且费用更低。

要点

  • MANTA组技术失败率8.3%,低于ProGlide组的15.6%(P<.001)。
  • MANTA组封堵不当发生率5.8%,低于ProGlide组的13.9%(P=.002)。
  • 两组出血率与股动脉切开转归率无显著差异,ProGlide费用更低。

核心结论

  • MANTA和ProGlide均为pEVAR大孔径动脉切开闭合的安全选择。
  • ProGlide首次成功率较低,但可通过追加另一器械解决,转开放率相当。
  • ProGlide的使用费用低于MANTA。

研究设计与样本

  • 单中心回顾性研究,连续纳入择期经皮腔内动脉瘤修复术(pEVAR)患者。
  • 共纳入263例患者,511个股总动脉穿刺点,MANTA组325个,ProGlide组186个。
  • 技术成功定义为器械部署后实现止血。

主要发现

  • 技术失败MANTA组27例(8.3%)vs ProGlide组29例(15.6%),P<.001。
  • 封堵不当MANTA组19例(5.8%)vs ProGlide组26例(13.9%),P=.002。
  • 术后出血MANTA组2例(1.2%)vs ProGlide组3例(1.6%),P=.721。
  • 股动脉切开MANTA组15例(4.6%)vs ProGlide组9例(4.8%),P=.909。

关键数值与推荐

  • 技术失败率MANTA组8.3% vs ProGlide组15.6%(P<.001)。
  • 封堵不当率MANTA组5.8% vs ProGlide组13.9%(P=.002)。
  • 术后出血率MANTA组1.2% vs ProGlide组1.6%(P=.721)。
  • 股动脉切开率MANTA组4.6% vs ProGlide组4.8%(P=.909)。

临床怎么用

  • 作者认为MANTA和ProGlide均可用于pEVAR大孔径动脉切开闭合。
  • 作者指出ProGlide首次成功率较低,但可通过追加另一器械解决。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The aim of this study is to compare the clinical outcomes of the MANTA and ProGlide devices in a real-world population of patients undergoing elective percutaneous endovascular aneurysm repair (pEVAR). METHODS: All consecutive patients undergoing percutaneous EVAR (pEVAR) in a single center were retrospectively reviewed. Technical success was defined as achieving hemostasis after device deployment. Complications were registered, including improper sealing after deployment, to conform with the instructions for use, bleeding after leaving the operating room, occlusion, stenosis, and false aneurysm. The conversion rate to femoral cut-down was registered as well. RESULTS: A total of 263 patients were included in the analysis, resulting in 511 common femoral artery puncture sites. There were 325 that were closed using MANTA and 186 using ProGlide. Technical failure occurred in 27 cases (8.3%) in the MANTA group and 29 cases (15.6%) in the ProGlide group (P < .001). Within these cases, improper sealing at the end of the procedure was found in 19 cases (5.8%) in the MANTA group and 26 (13.9%) in the ProGlide group (P = .002). Bleeding after the procedure ended occurred in two cases (1.2%) in the MANTA group and three cases (1.6%) in the ProGlide group (P = .721). Femoral cut-down was necessary in 15 cases in the MANTA group (4.6%). Cut-down was performed in 9 patients in the ProGlide group, representing 4.8% of the ProGlide group (P = .909). CONCLUSIONS: Both MANTA and ProGlide are safe options for the closure of large-bore arteriotomies in pEVAR. Although the ProGlide has a lower first success rate, its shortcomings are solved easily by adding another device, resulting in comparable conversion rates. Furthermore, ProGlide was less expensive to use than MANTA.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Oosterveld RJ, van Wely C, Bartholomeus Salemans P, et al. Single-center comparative study of MANTA and ProGlide vascular closure devices in percutaneous endovascular aneurysm repair. J Vasc Surg. 2025. PMID: 40447169. doi:10.1016/j.jvs.2025.05.040

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。