文献速递主动脉疾病

影像融合引导下顺行激光开窗技术治疗复杂主动脉瘤的中期结果

Midterm Results of Antegrade Laser Fenestrations Using Image Fusion Guidance in Complex Aortic Aneurysm Repair.
PubMed 文献 · Eur J Vasc Endovasc Surg · 2025-05-13

这项回顾性、观察性、单中心研究描述了使用顺行激光开窗和影像融合引导的医师改良覆膜支架(lEVAR)治疗复杂腹主动脉瘤、胸腹主动脉瘤和I型内漏的中期结果。共60例不适合开放手术的患者接受lEVAR,院内死亡率为5%,3年总体生存率和免于再干预率分别为81%和60.2%,3年靶血管通畅率为90.1%。作者认为,对于不适合开放手术的高危患者,lEVAR可能提供满意的中期总体生存率和靶血管通畅率,但再干预率较高,需要密切和广泛的随访。

要点

  • lEVAR技术成功率为98%,术中不良事件发生率为35%,院内死亡率为5%。
  • 中位随访35.7个月,3年总体生存率为81%(95%CI 68.3-89),免于再干预率为60.2%(95%CI 43.4-73.4)。
  • 3年靶血管通畅率为90.1%(95%CI 77.5-95.8),随访期间6条靶血管闭塞。

核心结论

  • 对于不适合开放手术的高危患者,lEVAR可能提供满意的中期总体生存率和靶血管通畅率,但本研究中再干预率较高,需要密切和广泛的随访。

研究设计与样本

  • 回顾性、观察性、单中心研究,纳入2016年9月1日至2022年1月1日期间的所有lEVAR手术,共60例患者。

主要发现

  • 60例患者均被评估为不适合开放手术,lEVAR病例包括12例症状性动脉瘤、33例直径>65 mm的扩张性动脉瘤、14例解剖限制和/或既往肾支架以及1例破裂。
  • 动脉瘤直径中位数为65.5 mm(IQR 13),共实施170个顺行激光开窗(平均2.8个/患者)。
  • 术中不良事件记录于21例(35%),技术成功率为98%,院内死亡率为5%(n=3)。
  • 中位随访35.7个月,3年总体生存率和免于再干预率分别为81%(95%CI 68.3-89)和60.2%(95%CI 43.4-73.4)。
  • 随访期间6条靶血管闭塞,3年靶血管通畅率为90.1%(95%CI 77.5-95.8);记录到2例lEVAR移植物取出,分别因感染或持续性内漏;3年免于主动脉死亡率为92%(95%CI 86.9-99.7)。

临床怎么用

  • 对于不适合开放手术的高危患者,lEVAR可能提供满意的中期总体生存率和靶血管通畅率,但再干预率较高,需要密切和广泛的随访。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: This retrospective, observational, single centre study aimed to describe midterm results of physician modified stent grafts using antegrade laser fenestrations and image fusion guidance (lEVAR) for the treatment of complex abdominal aortic aneurysms, thoraco-abdominal aortic aneurysms, and type I endoleaks. METHODS: All lEVAR procedures between 1 September 2016 and 1 January 2022 were reviewed. Endpoints included intra-operative adverse events (IOAEs), in hospital death, re-interventions, and target vessel patency. Midterm outcomes were estimated using the Kaplan-Meier time to event method with 95% confidence intervals (95% CI). RESULTS: Sixty patients underwent lEVAR procedures during the study period. All patients were deemed unfit for open repair. The lEVAR cases included 12 symptomatic aneurysms, 33 enlarging aneurysms > 65 mm, 14 anatomical constraints and or presence of previous renal stents, and one rupture. The median aneurysm diameter was 65.5 mm (IQR 13). One hundred and seventy antegrade laser fenestrations were performed (mean 2.8/patient). IOAEs were recorded in 21 cases (35%). Technical success was recorded in 98% of cases. The in hospital mortality rate was 5% (n = 3). The median follow up was 35.7 months. The estimates of overall survival and freedom from re-intervention at three years were 81% (95% CI 68.3 - 89) and 60.2% (95% CI 43.4 - 73.4), respectively. Six target vessels occluded during follow up, giving a three year target vessel patency rate of 90.1% (95% CI 77.5 - 95.8). Two lEVAR explantations were recorded during follow up, either for infection or persistent endoleak. The three year freedom from aortic death estimate was 92% (95% CI 86.9 - 99.7). CONCLUSION: In high risk patients deemed unfit for open repair, lEVAR may provide satisfactory midterm overall survival and target vessel patency rates, although re-intervention rates were high in this study, requiring close and extensive follow up.

来源:Eur J Vasc Endovasc Surg,查看原文。版权归原作者所有。

引用

  1. Sénémaud J, Canonge J, Touma J, et al. Midterm Results of Antegrade Laser Fenestrations Using Image Fusion Guidance in Complex Aortic Aneurysm Repair. Eur J Vasc Endovasc Surg. 2025. PMID: 40374070. doi:10.1016/j.ejvs.2025.04.071

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。