文献速递主动脉疾病

基于全球横断面调查的医师改良覆膜支架适应证、规划与技术要点

Indications, planning, and technical aspects in physician-modified endografts based on a cross-sectional global survey.
PubMed 文献 · J Vasc Surg · 2025-05-20

该全球横断面调查向4286名血管专科医生发放31题问卷,回收来自30个国家的227份回复。调查显示医师改良覆膜支架的适应证、器械选择、规划策略与技术细节存在较大差异,部分技术环节与术者经验显著相关。作者认为需标准化适应证、规划与操作,以提升手术安全性与一致性。

要点

  • 227份回复来自30个国家,85%为血管外科医生,21.6%完成超过30例PMEG。
  • 器械选择差异明显:52%偏好胸主动脉支架,30%偏好分叉型支架。
  • 近端密封区认知不一:26%认为15 mm足够,33%要求至少20 mm,29.1%选择25 mm或以上。

核心结论

  • 调查显示PMEG实践存在差异,若干技术环节与术者经验显著相关,作者认为需标准化适应证、规划与操作以提升手术安全性与一致性,并为未来研究、专家共识和结构化培训提供基础。

研究设计与样本

  • 全球横断面调查,采用31题网络问卷,通过电子邮件、专业网络和在线平台发放给4286名血管专科医生,历时6个月收集回复,采用描述性统计与亚组比较分析。

主要发现

  • 共收到来自30个国家的227份回复,85%为血管外科医生,21.6%完成超过30例PMEG。
  • 医疗法律顾虑常见,仅16.1%表示无此类顾虑。
  • 器械选择:52%偏好胸主动脉支架,30%偏好分叉型支架。
  • 规划策略:26%认为15 mm密封区足够,33%要求至少20 mm,29.1%选择25 mm或以上。
  • 67%不使用三维打印模板定位开窗,21.6%常规使用且多为院内打印;美国受访者较少将PMEG用于夹层后动脉瘤和严重靶血管狭窄,基于经验的分析发现若干背台修改技术存在显著差异。

关键数值与推荐

  • 密封区认知:26%认为15 mm足够,33%要求至少20 mm,29.1%选择25 mm或以上。
  • 器械偏好:52%选择胸主动脉支架,30%选择分叉型支架。
  • 三维打印模板:67%不使用,21.6%常规使用且多为院内打印。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess real-world variability in physician-modified endograft (PMEG) use through a global survey, providing insights to guide standardization and improve patient outcomes. METHODS: A global cross-sectional survey was conducted using a 31-question web-based questionnaire distributed to 4286 vascular specialists via email, professional networks, and online platforms. The survey addressed practitioner demographics, experience, PMEG indications, device selection, planning, and technical aspects. Responses were collected over 6 months and analyzed with descriptive statistics and subgroup comparisons. RESULTS: The survey received 227 responses from 30 countries; 85% were vascular surgeons and 21.6% had performed more than 30 PMEG cases. Medicolegal concerns were common, with only 16.1% reporting none. Device selection varied, with 52% preferring thoracic grafts and 30% bifurcated endografts. Planning strategies differed: 26% considered 15 mm a sufficient sealing zone, 33% required at least 20 mm, and 29.1% opted for 25 mm or more. Although 67% did not use three-dimensionally printed templates for fenestration positioning, 21.6% routinely did, mostly with in-house printing. Geographic analysis showed US respondents were less likely to use PMEG for postdissection aneurysms and severe target vessel stenosis, whereas experience-based analysis identified several significant differences in back-table modification techniques. CONCLUSIONS: This survey highlights variability in PMEG practice, with several technical aspects significantly associated with practitioner experience. The findings underscore the need to standardize indications, planning, and execution to enhance procedural safety and consistency, providing a foundation for future research, expert consensus, and structured training programs.

来源:J Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Robaldo A, Ruffino MA, Garbero E, et al. Indications, planning, and technical aspects in physician-modified endografts based on a cross-sectional global survey. J Vasc Surg. 2025. PMID: 40404023. doi:10.1016/j.jvs.2025.05.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。