文献速递外周动脉疾病主动脉疾病

股总动脉多普勒波形分析能否可靠预测主髂动脉显著病变:系统综述与Meta分析

Can Common Femoral Artery Doppler Waveform Analysis Reliably Predict Hemodynamically Significant Disease of the Aortoiliac Arteries? A Systematic Review and Meta-Analysis.
PubMed 文献 · Ann Vasc Surg · 2025-04-17

本系统综述与Meta分析纳入8项研究共1,139条肢体,评估股总动脉(CFA)波形分析对比参考检查诊断主髂动脉显著病变的准确性。汇总阴性预测值为84.7%(95%CI:59.3%-97.0%),阳性预测值为71.3%(95%CI:36.1%-93.1%),敏感度为0.86(95%CI:0.78-0.92),特异度为0.78(95%CI:0.61-0.89)。作者认为现有最佳数据提示CFA波形分析在识别和排除主髂动脉显著病变方面缺乏精确性。

要点

  • 汇总阴性预测值84.7%(95%CI:59.3%-97.0%),三相波形排除主髂动脉显著病变的可靠性有限。
  • 汇总敏感度0.86(95%CI:0.78-0.92),14%的主髂动脉显著病变患者仍表现为三相波形。
  • 作者认为在顺行血管内干预前可适当降低横断面成像的阈值。

核心结论

  • 现有最佳数据提示,与异质性参考检查相比,多普勒波形分析在识别和排除主髂动脉显著病变方面缺乏精确性。
  • 作者认为在顺行血管内干预前,可适当降低横断面成像的阈值。

研究设计与样本

  • 系统综述与Meta分析,检索MEDLINE、Embase、Cochrane图书馆及参考文献列表,纳入比较CFA波形分析与主髂动脉病变参考检查的研究。
  • 共纳入8项研究、1,139条肢体;三相波形视为正常,双相/单相视为异常。
  • 参考检查包括导管或横断面血管造影(n=5)、主髂动脉双功超声(n=2)及动脉内压力测定(n=1)。
  • 采用双变量模型进行Meta分析,得出汇总阴性预测值、阳性预测值、敏感度及特异度。

主要发现

  • 在有报告的数据中,平均年龄67岁,64.4%有间歇性跛行,35.6%有严重肢体缺血,42.3%为吸烟者,33.3%为糖尿病患者。
  • 汇总阴性预测值为84.7%(95%CI:59.3%-97.0%),即三相波形正确排除主髂动脉显著病变的概率为84.7%。
  • 汇总阳性预测值为71.3%(95%CI:36.1%-93.1%)。
  • 汇总敏感度为0.86(95%CI:0.78-0.92),表明14%的主髂动脉显著病变患者表现为三相波形。
  • 汇总特异度为0.78(95%CI:0.61-0.89)。

关键数值与推荐

  • 三相波形定义为正常,双相/单相波形定义为异常。
  • 汇总阴性预测值84.7%(95%CI:59.3%-97.0%),阳性预测值71.3%(95%CI:36.1%-93.1%)。
  • 汇总敏感度0.86(95%CI:0.78-0.92),特异度0.78(95%CI:0.61-0.89)。

临床怎么用

  • 部分中心采用「三相即向下」策略,即CFA波形为三相时直接进行膝下病变的顺行血管内干预。
  • 其他中心无论CFA波形如何均要求横断面成像以排除隐匿性主髂动脉病变。
  • 作者认为在顺行血管内干预前可适当降低横断面成像的阈值。

局限性

  • 参考检查异质性较大,包括导管或横断面血管造影、主髂动脉双功超声及动脉内压力测定。
  • 阴性预测值95%CI宽(59.3%-97.0%),阳性预测值95%CI宽(36.1%-93.1%),特异度95%CI宽(0.61-0.89)。
  • 作者结论用「suggests」表述,提示证据确定性有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Many guidelines recommend duplex scanning as the first-line investigation for peripheral arterial disease. Qualitative evaluation of the common femoral artery (CFA) waveform provides information regarding the likely presence of significant aortoiliac disease. Certain centers use a "triphasic-and-down" policy, proceeding directly to antegrade endovascular intervention of infra-inguinal disease if the CFA waveform is triphasic. Others mandate cross-sectional imaging regardless of CFA waveform to exclude occult aortoiliac disease. This review aims to analyze the reliability of CFA waveform in excluding significant aortoiliac disease. METHODS: MEDLINE, Embase, Cochrane library, and reference lists were searched for studies comparing CFA waveform analysis with reference tests assessing aortoiliac disease. Triphasic waveforms were considered "normal", while biphasic/monophasic were considered "abnormal." Meta-analyses using a bivariate model produced pooled diagnostic accuracy metrics, including negative and positive predictive values, sensitivity, and specificity. RESULTS: Eight studies with 1,139 limbs were included. Where reported, the mean age was 67, 64.4% had claudication and 35.6% had critical limb ischemia, 42.3% were smokers, and 33.3% were diabetic. Reference investigations were catheter or cross-sectional angiography(n = 5), aortoiliac duplex(n = 2), and intra-arterial pressures(n = 1). The pooled negative predictive value was 84.7% (95% confidence interval [CI]: 59.3%-97.0%), meaning a triphasic waveform correctly excludes significant aortoiliac disease 84.7% of the time, and positive predictive value was 71.3% (95% CI: 36.1%-93.1%). Sensitivity was 0.86 (95% CI: 0.78-0.92), indicating 14% of patients with significant aortoiliac disease had triphasic waveforms, and specificity was 0.78 (95% CI: 0.61-0.89). CONCLUSION: The best data available suggests Doppler waveform analysis lacks precision in identifying and excluding significant aortoiliac disease compared to heterogenous reference tests. A low threshold for cross-sectional imaging before antegrade endovascular intervention may be appropriate.

来源:Ann Vasc Surg,查看原文。版权归原作者所有。

引用

  1. Fabre I, Gwilym BL, Kabis M, et al. Can Common Femoral Artery Doppler Waveform Analysis Reliably Predict Hemodynamically Significant Disease of the Aortoiliac Arteries? A Systematic Review and Meta-Analysis. Ann Vasc Surg. 2025. PMID: 40252801. doi:10.1016/j.avsg.2025.04.064

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。